[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1144539":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1144539,800,2,"多选题","施工缝的位置应在混凝土浇筑之前确定，对于施工缝处施工要求，下列描述正确的是（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","施工缝的位置应在混凝土浇筑之前确定，并宜留置在结构受剪力较小且便于施工的部位",true,{"key":16,"text":17,"correct":14},"B","施工缝处混凝土，要待已浇筑的混凝土抗压强度等级达到不小于1.2N\u002Fmm2，才能继续浇筑",{"key":19,"text":20,"correct":14},"C","与板连成整体的大截面梁，施工缝宜留在板底面以下20～30mm处",{"key":22,"text":23,"correct":24},"D","单向板施工缝留在平行于长边的任何位置",false,{"key":26,"text":27,"correct":24},"E","有主次梁的楼板，宜顺着次梁浇筑，施工缝留置在次梁跨中的2\u002F3处","ABC","2020教材P111 \u002F 2019教材P110",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]