[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1143926":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1143926,800,2,"多选题","关于吊顶的装修构造及施工要求，表述正确的有()。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","吊点距主龙骨端部的距离不应大于200mm",false,{"key":16,"text":17,"correct":18},"B","石膏板等面层抹灰类吊顶，板缝须进行防开裂处理",true,{"key":20,"text":21,"correct":18},"C","大面积吊顶或在吊顶应力集中处应设置分缝",{"key":23,"text":24,"correct":18},"D","重型灯具、电扇及其他重型设备严禁安装在吊顶工程的龙骨上",{"key":26,"text":27,"correct":18},"E","对演出性厅堂和会议室等有音质要求的室内，吊顶应采用吸声扩散处理","BCDE","2020\u002F2019版教材P10 (三）吊顶的装修构造及施工要求(1)吊杆长度超过1.5m时，应设置反支撑或钢制转换层，增加吊顶的稳定性。(2)吊点距主龙骨端部的距离不应大于300mm.(3)龙骨在短向跨度上应根据材质适当起拱。(4)大面积吊顶或在吊顶应力集中处应设置分缝，留缝处龙骨和面层均应断开，以防止吊顶开裂。(5)石膏板等面层抹灰类吊顶，板缝须进行防开裂处理。(6)为解决振动传声问题，应在吊杆与结构连接之间、四周墙之间设置弹性阻尼材料，减少或隔绝振动传声。(7)对演出性厅堂和会议室等有音质要求的室内，吊顶应采用吸声扩散处理。(8)大量管道和电气线路均安装在吊顶内部；吊顶材料和构造设计根据规范要求，应考虑：防火、防潮、防水处理。(9)抹灰吊顶应设检修人孔及通风口，高大厅堂和管线较多的吊顶内，应留有检修空间，并根据需要设走道板。(10)重型灯具、电扇、风道及其他重型设备严禁安装在吊顶工程的龙骨上。所以选BCDE。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]