[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1143385":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1143385,800,2,"多选题","关于防水混凝土配合比的说法， 正确的有（）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","防水混凝土胶凝材料总量不宜小于300kg\u002Fm3，水泥用量不宜小于260kg\u002Fm3",false,{"key":16,"text":17,"correct":18},"B","水胶比不得大于0.50",true,{"key":20,"text":21,"correct":14},"C","入泵坍落度宜为100~140mm",{"key":23,"text":24,"correct":18},"D","掺引气剂时，混凝土含气量应控制在3%~5%",{"key":26,"text":27,"correct":18},"E","预拌混凝土初凝时间以为6~8h","BDE","防水混凝土配合比要求（注意区别泵送混凝土的配合比）。 （1）入泵坍落度控制在 120~160mm；（100mm） （2）砂率宜为 35%~40%； （3）用水量\u002F胶凝材料总量（水胶比）不得大于 0.5；（0.6） （4）胶凝材料总量不小于 320kg\u002Fm3（300kg\u002Fm3），水泥用量不小于 260kg\u002Fm3； （5）掺用引气型外加剂时，含气量控制在 3%~5%；（不宜大于 4%） （6）预拌混凝土的初凝时间宜为 6~8h。",{"id":6,"name":31,"category":32,"favorite":33},"一建建筑工程实务","建筑工程",0]