[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-797-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":613},{"id":5,"name":6,"category":7,"favorite":8},797,"一建机电工程实务","建筑工程",0,8,50,2021,[13,34,46,58,70,82,93,105,117,129,141,153,165,177,189,201,213,225,236,248,260,272,284,296,308,320,332,344,356,368,380,392,404,416,428,440,452,464,476,487,498,509,521,533,545,557,569,581,593,603],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1135677,1,"单选题","（）地脚螺栓是一种可拆卸的地脚螺栓，用于工作时有强烈震动和冲击的设备。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","活动",true,{"key":24,"text":25,"correct":26},"B","固定",false,{"key":28,"text":29,"correct":26},"C","胀锚",{"key":31,"text":32,"correct":26},"D","粘接","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1135678,"T型头地脚锚栓安装时，其光杆部分和基础板应（）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"电焊牢固",{"key":24,"text":41,"correct":26},"及时灌浆",{"key":28,"text":43,"correct":26},"除漆除锈",{"key":31,"text":45,"correct":22},"涂防锈漆",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},1135679,"预埋地脚螺栓验收时，除验收地脚螺栓的位置标高外还应对（）进行验收。",[50,52,54,56],{"key":20,"text":51,"correct":26},"预埋方式",{"key":24,"text":53,"correct":26},"垫铁的预留空间",{"key":28,"text":55,"correct":22},"螺栓露出基础的长度",{"key":31,"text":57,"correct":26},"螺栓的保护措施",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1135680,"解体安装是在安装施工现场，重新按设计及（）要求进行装配和安装。",[62,64,66,68],{"key":20,"text":63,"correct":22},"制造",{"key":24,"text":65,"correct":26},"规范",{"key":28,"text":67,"correct":26},"生产",{"key":31,"text":69,"correct":26},"工艺",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},1135681,"胀锚地脚螺栓施工时，螺栓中心到基础边缘的距离不得小于（）倍的胀锚地脚螺栓直径。",[74,76,78,80],{"key":20,"text":75,"correct":22},"7",{"key":24,"text":77,"correct":26},"8",{"key":28,"text":79,"correct":26},"9",{"key":31,"text":81,"correct":26},"10",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1135682,"提高安装精度应从人、机、料、法、环等方面着手，尤其要强调施工（）的作用。",[86,88,90,92],{"key":20,"text":87,"correct":26},"环境",{"key":24,"text":89,"correct":22},"人员",{"key":28,"text":91,"correct":26},"机具",{"key":31,"text":69,"correct":26},{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":31,"analysis":33},1135683,"设备安装精度测量时，下列误差中，属于形状误差的是（）。",[97,99,101,103],{"key":20,"text":98,"correct":26},"垂直度",{"key":24,"text":100,"correct":26},"同轴度",{"key":28,"text":102,"correct":26},"倾斜度",{"key":31,"text":104,"correct":22},"圆柱度",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":20,"analysis":33},1135684,"下列设备基础中，属于结构形式分类的是（）。",[109,111,113,115],{"key":20,"text":110,"correct":22},"大块式基础",{"key":24,"text":112,"correct":26},"垫层基础",{"key":28,"text":114,"correct":26},"深基础",{"key":31,"text":116,"correct":26},"减振基础",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":28,"analysis":33},1135685,"机械设备与基础的连接方式中，用来固定没有强烈振动和冲击的设备是（）。",[121,123,125,127],{"key":20,"text":122,"correct":26},"胀锚地脚螺栓",{"key":24,"text":124,"correct":26},"活动地脚螺栓",{"key":28,"text":126,"correct":22},"固定地脚螺栓",{"key":31,"text":128,"correct":26},"黏结地脚螺栓",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":28,"analysis":33},1135686,"现场组装大型设备各运动部件之间的相对运动精度一般不包括（）。",[133,135,137,139],{"key":20,"text":134,"correct":26},"直线运动精度",{"key":24,"text":136,"correct":26},"圆周运动精度",{"key":28,"text":138,"correct":22},"平面度",{"key":31,"text":140,"correct":26},"传动精度",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":28,"analysis":33},1135687,"修配法是对补偿件进行补充加工，其目的是（）。",[145,147,149,151],{"key":20,"text":146,"correct":26},"修复施工中的缺陷",{"key":24,"text":148,"correct":26},"修补设备制造中的缺陷",{"key":28,"text":150,"correct":22},"抵消过大的安装积累误差",{"key":31,"text":152,"correct":26},"补充设计的不足",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":28,"analysis":33},1135688,"机械设备安装时，设备固定与灌浆的紧前工作是（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":26},"垫铁设置",{"key":24,"text":160,"correct":26},"设备装配",{"key":28,"text":162,"correct":22},"安装精度调整与检测",{"key":31,"text":164,"correct":26},"吊装就位",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":24,"analysis":33},1135689,"下列关于机械设备安装工作说法错误的是（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":26},"可以通过调整垫铁的厚度，使设备安装达到设计或规范要求的标高和水平度",{"key":24,"text":172,"correct":22},"设备二次灌浆是在设备精找正后，对地脚螺栓孔进行的灌浆",{"key":28,"text":174,"correct":26},"一般解体设备装配顺序为：组合件装配→部件装配→总装配",{"key":31,"text":176,"correct":26},"可以通过润滑剂减少摩擦副的摩擦、表面破坏和降低温度，使设备具有良好工作性能，延长使用寿命",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":28,"analysis":33},1135690,"在电动机干燥过程中，错误的做法是（）。",[181,183,185,187],{"key":20,"text":182,"correct":26},"每小时的温升控制在7℃左右",{"key":24,"text":184,"correct":26},"绕组的最高温度应控制在75℃",{"key":28,"text":186,"correct":22},"干燥时用水银温度计测量温度",{"key":31,"text":188,"correct":26},"测量绕组绝缘电阻时断开电源",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":31,"analysis":33},1135691,"变电站是采用（）来限制入侵雷电波的过电压幅值",[193,195,197,199],{"key":20,"text":194,"correct":26},"接闪针",{"key":24,"text":196,"correct":26},"接闪线",{"key":28,"text":198,"correct":26},"接闪带",{"key":31,"text":200,"correct":22},"阀型接闪器",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":33},1135693,"测量变压器绕组连同套管一起的直流电阻，与同温下产品出厂实测数值比较，相应变化（）。",[205,207,209,211],{"key":20,"text":206,"correct":22},"不应大于2%",{"key":24,"text":208,"correct":26},"不应大于3%",{"key":28,"text":210,"correct":26},"不应大于5%",{"key":31,"text":212,"correct":26},"不应大于6%",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":24,"analysis":33},1135694,"关于导线连接要求,错误的说法是（）。",[217,219,221,223],{"key":20,"text":218,"correct":26},"跨越河流的导线不允许有接头",{"key":24,"text":220,"correct":22},"跨越铁路的导线允许有接头",{"key":28,"text":222,"correct":26},"电阻不超过同长度导线电阻的1.2倍",{"key":31,"text":224,"correct":26},"接头处的机械强度不低于导线自身强度的90%",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":28,"analysis":33},1135695,"当电动机绝缘电阻值达到规范要求时，在同一温度下经（）h稳定不变时方可认为干燥完毕。",[229,231,233,235],{"key":20,"text":230,"correct":26},"1",{"key":24,"text":232,"correct":26},"3",{"key":28,"text":234,"correct":22},"5",{"key":31,"text":75,"correct":26},{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":31,"analysis":33},1135696,"下列不属于成套配电装置主要整定内容的是（）。",[240,242,244,246],{"key":20,"text":241,"correct":26},"过电流保护整定",{"key":24,"text":243,"correct":26},"零序过电流保护整定",{"key":28,"text":245,"correct":26},"过负荷告警整定",{"key":31,"text":247,"correct":22},"双相一次重合闸整定",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":24,"analysis":33},1135697,"金属氧化物接闪器安装后，需测量金属氧化物接闪器的（）。",[252,254,256,258],{"key":20,"text":253,"correct":26},"工频放电电压",{"key":24,"text":255,"correct":22},"持续电流",{"key":28,"text":257,"correct":26},"放电电流",{"key":31,"text":259,"correct":26},"短路电流",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":20,"analysis":33},1135698,"成套配电装置送电验收，由供电部门检查合格后将电源送进室内，经过验电、校相无误后合（）。",[264,266,268,270],{"key":20,"text":265,"correct":22},"高压柜进线开关",{"key":24,"text":267,"correct":26},"变压器柜开关",{"key":28,"text":269,"correct":26},"低压柜进线开关",{"key":31,"text":271,"correct":26},"其他柜的开关",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":31,"analysis":33},1135699,"下列要求中，不属于配电柜基本要求的是（）。",[276,278,280,282],{"key":20,"text":277,"correct":26},"将柜体按编号顺序分别安装在基础型钢上，再找平找正。",{"key":24,"text":279,"correct":26},"柜体的接地应牢固、可靠，以确保安全。装有电器的可开启的柜门应以裸铜软线与金属柜体可靠连接",{"key":28,"text":281,"correct":26},"基础型钢的安装垂直度、水平度允许偏差，位置偏差及不平行度，基础型钢顶部平面，应符合规定",{"key":31,"text":283,"correct":22},"机械联锁装置应采用钢丝",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":31,"analysis":33},1135700,"接地模块的施工时，接地模块的顶面埋深不应小于（）。",[288,290,292,294],{"key":20,"text":289,"correct":26},"0.3m",{"key":24,"text":291,"correct":26},"0.4m",{"key":28,"text":293,"correct":26},"0.5m",{"key":31,"text":295,"correct":22},"0.6m",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":24,"analysis":33},1135701,"配电柜的基础型钢的接地应不少于（）。",[300,302,304,306],{"key":20,"text":301,"correct":26},"1处",{"key":24,"text":303,"correct":22},"2处",{"key":28,"text":305,"correct":26},"3处",{"key":31,"text":307,"correct":26},"4处",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":31,"analysis":33},1135702,"下列整定内容,属于成套配电装置过电流保护整定的是（）。",[312,314,316,318],{"key":20,"text":313,"correct":26},"合闸元件整定",{"key":24,"text":315,"correct":26},"温度元件整定",{"key":28,"text":317,"correct":26},"方向元件整定",{"key":31,"text":319,"correct":22},"时间元件整定",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":28,"analysis":33},1135703,"电动机的保护接地线必须连接可靠，铜芯接地线的截面不小于（）。",[324,326,328,330],{"key":20,"text":325,"correct":26},"1.5mm2",{"key":24,"text":327,"correct":26},"2.5mm2",{"key":28,"text":329,"correct":22},"4.0mm2",{"key":31,"text":331,"correct":26},"6.0mm2",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":28,"analysis":33},1135704,"在变压器二次搬运中，做法错误的是（）。",[336,338,340,342],{"key":20,"text":337,"correct":26},"钢丝绳挂在油箱吊钩上",{"key":24,"text":339,"correct":26},"用纸箱将绝缘瓷瓶罩住",{"key":28,"text":341,"correct":22},"变压器倾斜不超过25°",{"key":31,"text":343,"correct":26},"检查核对各受力点是否均匀",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},1135705,"1kV及以下电机使用500~1000V摇表，绝缘电阻值不应低于（）",[348,350,352,354],{"key":20,"text":349,"correct":26},"0.5MΩ\u002FkV",{"key":24,"text":351,"correct":22},"1MΩ\u002FkV",{"key":28,"text":353,"correct":26},"2MΩ\u002FkV",{"key":31,"text":355,"correct":26},"5MΩ\u002FkV",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":20,"analysis":33},1135706,"充氮气运输的变压器应有压力监视和补充装置，在运输过程中应保持（）的正压。",[360,362,364,366],{"key":20,"text":361,"correct":22},"0.01～0.03mPa",{"key":24,"text":363,"correct":26},"0.03～0.06mPa",{"key":28,"text":365,"correct":26},"0.06～0.09mPa",{"key":31,"text":367,"correct":26},"0.09～0.12mPa",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":33},1135707,"下列电缆沟内电缆的敷设要求，其中错误的是（）。",[372,374,376,378],{"key":20,"text":373,"correct":22},"控制电缆在普通支架上敷设不宜超过3层",{"key":24,"text":375,"correct":26},"电力电缆与控制电缆应按顺序分层配置",{"key":28,"text":377,"correct":26},"交流三芯电力电缆在支架上不宜超过1层",{"key":31,"text":379,"correct":26},"交流单芯电力电缆应布置在同侧支架上",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":31,"analysis":33},1135708,"110kV电力变压器新装注油后，可以进行耐压试验的是（）。",[384,386,388,390],{"key":20,"text":385,"correct":26},"静置了5h",{"key":24,"text":387,"correct":26},"静置了6h",{"key":28,"text":389,"correct":26},"静置了10h",{"key":31,"text":391,"correct":22},"静置了12h",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":31,"analysis":33},1135709,"接闪器安装不符合要求的是（）。",[396,398,400,402],{"key":20,"text":397,"correct":26},"应进行检查。接闪器组装时，各节位置符合出厂标志的编号",{"key":24,"text":399,"correct":26},"排气式接闪器的安装，应避免其排出的气体引起相间或对地闪络，不能喷及其他电气设备",{"key":28,"text":401,"correct":26},"氧化锌接闪器的接地线应用截面积不小于16mm2的软铜线",{"key":31,"text":403,"correct":22},"管型接闪器与被保护设备的连接线长度不得大于5m",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":31,"analysis":33},1135710,"关于电缆敷设前的检查说法，错误的是（）。",[408,410,412,414],{"key":20,"text":409,"correct":26},"电缆通道畅通，排水良好，金属部分的防腐层完整",{"key":24,"text":411,"correct":26},"电缆型号、规格、电压应符合设计要求",{"key":28,"text":413,"correct":26},"电缆外观应无损伤、绝缘良好",{"key":31,"text":415,"correct":22},"充油电缆的油压不宜低于0.05MPa",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":20,"analysis":33},1135711,"下列选项中，（）是一种传统的接地极，采用镀锌角钢、镀锌钢管、铜棒或铜板等金属材料，按照一定的技术要求，通过现场加工制作而成的。",[420,422,424,426],{"key":20,"text":421,"correct":22},"金属接地极",{"key":24,"text":423,"correct":26},"非金属接地极",{"key":28,"text":425,"correct":26},"离子接地极",{"key":31,"text":427,"correct":26},"降阻剂",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":31,"analysis":33},1135712,"测量额定为6kV的电动机绝缘电阻，应使用（）摇表。",[432,434,436,438],{"key":20,"text":433,"correct":26},"250V",{"key":24,"text":435,"correct":26},"500V",{"key":28,"text":437,"correct":26},"1000V",{"key":31,"text":439,"correct":22},"2500V",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":33},1135713,"下列是电缆沟内电缆敷设的要求，其中错误的是（）。",[444,446,448,450],{"key":20,"text":445,"correct":22},"电力电缆和控制电缆应配置在同一层支架上",{"key":24,"text":447,"correct":26},"高低压电力电缆、强电与弱电控制电缆应按顺序分层配置，一般情况宜由上而下配置",{"key":28,"text":449,"correct":26},"交流单芯电力电缆，应布置在同侧支架上",{"key":31,"text":451,"correct":26},"控制电缆在普通支架上，不宜超过1层；桥架上不宜超过3层",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":31,"analysis":33},1135714,"电压等级（）的输电线路，一般沿全线装设单避雷线，在雷电特别强烈地区采用双避雷线。",[456,458,460,462],{"key":20,"text":457,"correct":26},"500kV",{"key":24,"text":459,"correct":26},"330kV",{"key":28,"text":461,"correct":26},"220kV",{"key":31,"text":463,"correct":22},"110kV",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":31,"analysis":33},1135715,"下列高压开关设备试验的内容中，不属于高压真空开关试验的内容是（）。",[468,470,472,474],{"key":20,"text":469,"correct":26},"关断能力试验",{"key":24,"text":471,"correct":26},"主回路电阻测量和温升试验",{"key":28,"text":473,"correct":26},"绝缘试验",{"key":31,"text":475,"correct":22},"漏气率检查",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":31,"analysis":33},1135716,"电缆线路在进行直流耐压试验的同时，用接在高压侧的微安表测量三相（）。",[480,481,483,485],{"key":20,"text":259,"correct":26},{"key":24,"text":482,"correct":26},"过载电流",{"key":28,"text":484,"correct":26},"试验电流",{"key":31,"text":486,"correct":22},"泄漏电流",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":31,"analysis":33},1135717,"下列不属于真空高压开关设备试验内容的是（）。",[491,493,495,496],{"key":20,"text":492,"correct":26},"机械试验",{"key":24,"text":494,"correct":26},"内部故障试验",{"key":28,"text":471,"correct":26},{"key":31,"text":497,"correct":22},"漏气及含水率试验",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":24,"analysis":33},1135718,"直埋电缆埋深应不小于（）",[502,503,505,507],{"key":20,"text":295,"correct":26},{"key":24,"text":504,"correct":22},"0.7m",{"key":28,"text":506,"correct":26},"0.9m",{"key":31,"text":508,"correct":26},"1.0m",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":24,"analysis":33},1135719,"关于变压器就位的说法错误的是（）。",[513,515,517,519],{"key":20,"text":514,"correct":26},"在变压器就位后，应将滚轮用能拆卸的制动装置加以固定",{"key":24,"text":516,"correct":22},"变压器就位不宜吊车直接吊装就位",{"key":28,"text":518,"correct":26},"变应器就位时，应注意其方位和距墙尺寸应与设计要求相符",{"key":31,"text":520,"correct":26},"变压器与封闭母线直接时，其套管中心线应与封闭母线中心线相符",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":20,"analysis":33},1135720,"在架空线路施工的一般程序中，线路测量的下一步骤是（）。",[525,527,529,531],{"key":20,"text":526,"correct":22},"基础施工",{"key":24,"text":528,"correct":26},"杆塔组立",{"key":28,"text":530,"correct":26},"放线架线",{"key":31,"text":532,"correct":26},"导线连接",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":20,"analysis":33},1135721,"电气工程安装中的变压器就位安装应按图纸设计要求进行，其方位和距墙尺寸应与图纸相符。装有气体继电器的变压器应有（）坡度，高的一侧装在油枕方向，使气体继电器有良好的灵敏度。",[537,539,541,543],{"key":20,"text":538,"correct":22},"1％～1.5％",{"key":24,"text":540,"correct":26},"1.5％～2.0％",{"key":28,"text":542,"correct":26},"2.5％～3.5％",{"key":31,"text":544,"correct":26},"2.0%～3.0%",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},1135722,"装有电器的可开启的配电柜门与柜体框架可靠连接的导线应采用（）。",[549,551,553,555],{"key":20,"text":550,"correct":26},"绝缘导线",{"key":24,"text":552,"correct":22},"裸铜软线",{"key":28,"text":554,"correct":26},"绿黄导线",{"key":31,"text":556,"correct":26},"裸铜硬线",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":24,"analysis":33},1135723,"架空线路的竣工验收检查中，错误的要求是（）。",[561,563,565,567],{"key":20,"text":562,"correct":26},"电杆横担与线路中心垂直",{"key":24,"text":564,"correct":22},"35kV线路及以上的支柱绝缘子的绝缘电阻值，不应低于500MΩ",{"key":28,"text":566,"correct":26},"双杆基坑根开的中心偏差不应超过30mm",{"key":31,"text":568,"correct":26},"额定电压下对空载线路冲击合闸3次",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":20,"analysis":33},1135724,"下列开关柜的检查内容，不属于送电前检查的是（）。",[573,575,577,579],{"key":20,"text":574,"correct":22},"检查开关柜的型号规格",{"key":24,"text":576,"correct":26},"检查开关柜内电器接线",{"key":28,"text":578,"correct":26},"检查开关柜的机械联锁",{"key":31,"text":580,"correct":26},"检查开关柜的接地装置",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":24,"analysis":33},1135725,"下列变压器分接的电压比的检查，正确的是（）。",[585,587,589,591],{"key":20,"text":586,"correct":26},"变压器额定分接下电压比允许偏差不应超过±1.0%",{"key":24,"text":588,"correct":22},"电压等级35kv以下，电压比小于3的变压器电压比允许偏差应为±1.0%",{"key":28,"text":590,"correct":26},"电压比应在变压器阻抗电压值（%）的1\u002F5以内",{"key":31,"text":592,"correct":26},"变压器阻抗电压值（%）的允许偏差应为±3%",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":24,"analysis":33},1135726,"直埋电缆应使用铠装电缆，在铠装电缆的金属外皮两端要可靠接地，接地电阻不得大于（）Ω。",[597,598,599,601],{"key":20,"text":234,"correct":26},{"key":24,"text":81,"correct":22},{"key":28,"text":600,"correct":26},"15",{"key":31,"text":602,"correct":26},"20",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":31,"analysis":33},1135727,"220kV电压等级输电线路应全线装设（）。",[607,609,610,611],{"key":20,"text":608,"correct":26},"接闪器",{"key":24,"text":194,"correct":26},{"key":28,"text":196,"correct":26},{"key":31,"text":612,"correct":22},"双接闪线",[614,617,620,623,626,629],{"id":15,"name":615,"category":7,"favorite":616},"领导干部任职前廉政法规知识测试题",92,{"id":618,"name":619,"category":7,"favorite":15},595,"建筑结构与设备",{"id":621,"name":622,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":624,"name":625,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":627,"name":628,"category":7,"favorite":8},534,"BIM工程师",{"id":630,"name":628,"category":7,"favorite":8},535]