[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-797-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":601},{"id":5,"name":6,"category":7,"favorite":8},797,"一建机电工程实务","建筑工程",0,4,50,2021,[13,34,46,58,70,78,90,102,114,126,138,150,162,174,186,198,210,222,234,246,258,270,280,292,300,312,324,336,348,360,372,384,396,408,420,432,443,455,464,476,488,500,512,524,536,548,556,568,577,589],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1135477,1,"单选题","下列焊剂中，不属于按照焊剂添加脱氧剂、合金剂分类的是（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","中性焊剂",false,{"key":24,"text":25,"correct":26},"B","粘接焊剂",true,{"key":28,"text":29,"correct":22},"C","活性焊剂",{"key":31,"text":32,"correct":22},"D","合金焊剂","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1135478,"预防焊接变形可以采取合理的焊接工艺措施，下列属于焊接工艺措施的是（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"合理选择焊缝尺寸和形状",{"key":24,"text":41,"correct":26},"合理的焊接线能量",{"key":28,"text":43,"correct":22},"预留收缩余量",{"key":31,"text":45,"correct":22},"合理选择装配程序",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1135479,"焊接工艺评定报告的批准人是（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"焊接责任工程师",{"key":24,"text":53,"correct":22},"项目总工程师",{"key":28,"text":55,"correct":22},"项目质量检验工程师",{"key":31,"text":57,"correct":26},"焊接技术负责人",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1135480,"焊接合金结构钢，焊条的选择一般要求熔敷金属的（）与母材金属相同或接近。",[62,64,66,68],{"key":20,"text":63,"correct":22},"屈服强度",{"key":24,"text":65,"correct":22},"抗拉强度",{"key":28,"text":67,"correct":26},"合金成分",{"key":31,"text":69,"correct":22},"冲击韧性",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1135481,"焊接普通结构钢时，焊条选择（）等于或稍高于母材的焊条。",[74,75,76,77],{"key":20,"text":63,"correct":22},{"key":24,"text":65,"correct":26},{"key":28,"text":67,"correct":22},{"key":31,"text":69,"correct":22},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},1135482,"（）是指为验证所拟定的焊件焊接工艺的正确性而进行的试验过程及结果评价。",[82,84,86,88],{"key":20,"text":83,"correct":22},"质量证明文件",{"key":24,"text":85,"correct":26},"焊接工艺评定",{"key":28,"text":87,"correct":22},"焊接作业指导书",{"key":31,"text":89,"correct":22},"焊接工艺规程",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":24,"analysis":33},1135483,"在被焊结构刚性大、接头应力高、焊缝易产生裂纹的情况下，焊条选择时可以考虑选用比母材（）的焊条。",[94,96,98,100],{"key":20,"text":95,"correct":22},"同一强度级别",{"key":24,"text":97,"correct":26},"低一强度级别",{"key":28,"text":99,"correct":22},"高一强度级别",{"key":31,"text":101,"correct":22},"相同或高一强度级别",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":20,"analysis":33},1135484,"对承受动载荷和冲击载荷的焊件，除满足强度要求外，应选用塑性和韧性指标较高的（）焊条。",[106,108,110,112],{"key":20,"text":107,"correct":26},"低氢型",{"key":24,"text":109,"correct":22},"钛钙型",{"key":28,"text":111,"correct":22},"纤维类型",{"key":31,"text":113,"correct":22},"酸性",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},1135485,"在（）情况下，宜选用熔敷金属的抗拉强度稍高于母材的焊条。",[118,120,122,124],{"key":20,"text":119,"correct":22},"在焊接结构刚性大",{"key":24,"text":121,"correct":26},"非合金钢和低合金钢",{"key":28,"text":123,"correct":22},"接头应力高",{"key":31,"text":125,"correct":22},"焊接易产生裂纹",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},1135486,"焊接工艺评定焊接试件的施焊人员应是（）。",[130,132,134,136],{"key":20,"text":131,"correct":22},"第三方技能熟练的焊接人员",{"key":24,"text":133,"correct":26},"本单位技能熟练的焊接人员",{"key":28,"text":135,"correct":22},"本单位焊接质量管理人员",{"key":31,"text":137,"correct":22},"钢材供应单位持证焊工",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":20,"analysis":33},1135487,"焊接时随焊接热过程而发生的构件变形是（）。",[142,144,146,148],{"key":20,"text":143,"correct":26},"瞬态热变形",{"key":24,"text":145,"correct":22},"残余变形",{"key":28,"text":147,"correct":22},"弹性变形",{"key":31,"text":149,"correct":22},"塑性变形",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":33},1135488,"焊接作业前，应由（）向焊工发放相应的WPS并进行技术交底",[154,156,158,160],{"key":20,"text":155,"correct":26},"焊接技术人员",{"key":24,"text":157,"correct":22},"项目技术负责人",{"key":28,"text":159,"correct":22},"项目经理",{"key":31,"text":161,"correct":22},"施工单位技术负责人",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":31,"analysis":33},1135489,"常用于等离子弧切割，作为外层保护气的是（）。",[166,168,170,172],{"key":20,"text":167,"correct":22},"氩气",{"key":24,"text":169,"correct":22},"氦气",{"key":28,"text":171,"correct":22},"二氧化碳",{"key":31,"text":173,"correct":26},"氮气",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":31,"analysis":33},1135490,"下列检测内容中，不属于焊评试件检验项目的是（）。",[178,180,182,184],{"key":20,"text":179,"correct":22},"无损检测",{"key":24,"text":181,"correct":22},"力学性能试验",{"key":28,"text":183,"correct":22},"弯曲试验",{"key":31,"text":185,"correct":26},"压力试验",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},1135491,"与焊接线能量无关的因素是（）。",[190,192,194,196],{"key":20,"text":191,"correct":22},"焊接速度",{"key":24,"text":193,"correct":26},"焊接温度",{"key":28,"text":195,"correct":22},"焊接电流",{"key":31,"text":197,"correct":22},"电弧电压",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},1135492,"在焊前装配时先将焊件向焊接变形相反的方向进行人为变形的方法，是预防焊接变形装配工艺措施中的（）。",[202,204,206,208],{"key":20,"text":203,"correct":26},"反变形法",{"key":24,"text":205,"correct":22},"刚性固定法",{"key":28,"text":207,"correct":22},"预留收缩余量法",{"key":31,"text":209,"correct":22},"层间锤击法",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},1135493,"下列选项中，属于降低焊接应力设计措施的是（）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"合理安排焊接顺序",{"key":24,"text":217,"correct":26},"减少焊缝的数量",{"key":28,"text":219,"correct":22},"焊后进行消氢处理",{"key":31,"text":221,"correct":22},"整体预热",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":28,"analysis":33},1135494,"焊接工艺的评定中，钢结构的评定依据是（）。",[226,228,230,232],{"key":20,"text":227,"correct":22},"《钢结构设计规范》GB50017-2003",{"key":24,"text":229,"correct":22},"《建筑钢结构焊接技术规程》JGJ81-2002",{"key":28,"text":231,"correct":26},"《钢结构焊接规范》GB50661-2011",{"key":31,"text":233,"correct":22},"《钢结构制作与安装施工规程》YB9254-1995",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},1135495,"下列关于特种设备的焊接材料复验说法错误的是（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"球罐用的焊条和药芯焊丝应按批号进行扩散氢复验",{"key":24,"text":241,"correct":22},"工业管道用的焊条、焊丝、焊剂库存超过期限，应经复验合格后方可使用",{"key":28,"text":243,"correct":22},"酸性焊接材料及防潮包装密封良好的低氢型焊接材料的规定期限一般为2年",{"key":31,"text":245,"correct":26},"石墨型焊接材料及其他焊接材料的规定期限为2年",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},1135496,"下列关于钨极惰性气体保护焊特点说法错误的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"焊接工艺适用性强，几乎可以焊接所有的金属材料",{"key":24,"text":253,"correct":22},"焊接场地不受限制",{"key":28,"text":255,"correct":22},"焊接过程不产生溶渣",{"key":31,"text":257,"correct":26},"焊接过程有烟尘和飞溅，需要做好个体防护",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":20,"analysis":33},1135497,"下列不属于焊接技术交底内容的是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":26},"预焊接工艺规程内容",{"key":24,"text":265,"correct":22},"焊接质量检验计划",{"key":28,"text":267,"correct":22},"进度要求",{"key":31,"text":269,"correct":22},"焊接工程特点",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":33},1135498,"预防焊接变形的装配工艺措施是（ ）。",[274,275,276,278],{"key":20,"text":39,"correct":22},{"key":24,"text":45,"correct":26},{"key":28,"text":277,"correct":22},"合理安排焊缝位置",{"key":31,"text":279,"correct":22},"合理的焊接顺序和方向",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":31,"analysis":33},1135499,"下列不属于焊接变形危害的是（ ）。",[284,286,288,290],{"key":20,"text":285,"correct":22},"降低装配质量",{"key":24,"text":287,"correct":22},"降低承载力",{"key":28,"text":289,"correct":22},"提高制造成本",{"key":31,"text":291,"correct":26},"降低矫正工序",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":24,"analysis":33},1135500,"与焊接线能量有直接关系的因素不包括（ ）。",[296,297,298,299],{"key":20,"text":195,"correct":22},{"key":24,"text":193,"correct":26},{"key":28,"text":197,"correct":22},{"key":31,"text":191,"correct":22},{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":33},1135501,"常用的无损检测方法中，适合于焊缝内部缺陷检测的方法是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":26},"射线探伤",{"key":24,"text":307,"correct":22},"涡流探伤",{"key":28,"text":309,"correct":22},"磁性探伤",{"key":31,"text":311,"correct":22},"渗透探伤",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":28,"analysis":33},1135502,"下列不属于防止产生再热裂纹方法的是（ ）。",[316,318,320,322],{"key":20,"text":317,"correct":22},"减少焊接应力",{"key":24,"text":319,"correct":22},"预热",{"key":28,"text":321,"correct":26},"降低塑性变形能力",{"key":31,"text":323,"correct":22},"用低强度焊缝",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":28,"analysis":33},1135503,"关于建筑管道安装要求的说法,正确的是（ ）。",[328,330,332,334],{"key":20,"text":329,"correct":22},"室内给水管道安装应先支管后主管",{"key":24,"text":331,"correct":22},"应先安装塑料管道后安装钢质管道",{"key":28,"text":333,"correct":26},"铸铁管的坡度应高于塑料管的坡度",{"key":31,"text":335,"correct":22},"热水管道应平行安装在冷水管道下方",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":28,"analysis":33},1135504,"关于建筑室内给水排水管道安装的技术要求,正确的是（ ）。",[340,342,344,346],{"key":20,"text":341,"correct":22},"室内给水引入管与排水排出管的水平净距不得小于0.5m",{"key":24,"text":343,"correct":22},"室内给水与排水管道交叉敷设时的垂直净距不得小于0.5m",{"key":28,"text":345,"correct":26},"室内给水与排水管道平行敷设时的水平净距不得小于0.5m",{"key":31,"text":347,"correct":22},"敷设在排水管下面时的给水管应安装排水管管径2倍的套管",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":28,"analysis":33},1135505,"下列表述正确的是（ ），",[352,354,356,358],{"key":20,"text":353,"correct":22},"排水管道水平干管安装结束后通球率必须达到50%",{"key":24,"text":355,"correct":22},"通球球径不小于排水管道管径的1\u002F3",{"key":28,"text":357,"correct":26},"热水管道系统冲洗时，应先冲洗热水管道底部干管，后冲洗各环路支管",{"key":31,"text":359,"correct":22},"对于建筑物内不同材质的管道，应先安装塑料管道，后安装钢制管道",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":28,"analysis":33},1135506,"室内排水主管及水平干管，安装结束后均应作通球试验，通球球径不小于排水管径的（ ），通球率达到100%为合格。",[364,366,368,370],{"key":20,"text":365,"correct":22},"1\u002F2",{"key":24,"text":367,"correct":22},"1\u002F3",{"key":28,"text":369,"correct":26},"2\u002F3",{"key":31,"text":371,"correct":22},"3\u002F4",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":31,"analysis":33},1135507,"高层建筑管道常用的连接方法中，承插连接用于（ ）。",[376,378,380,382],{"key":20,"text":377,"correct":22},"PPR管的连接",{"key":24,"text":379,"correct":22},"镀锌钢管",{"key":28,"text":381,"correct":22},"铝塑复合管",{"key":31,"text":383,"correct":26},"给水及排水铸铁管及管件的连接",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":28,"analysis":33},1135508,"室内给水工程施工程序：室内给水管道施工程序：施工准备→预留、预埋→管道测绘放线→ 管道元件检验→管道支吊架制作安装→管道加工预制→ 给水设备安装→（ ）",[388,390,392,394],{"key":20,"text":389,"correct":22},"系统清洗→管道系统试验→防腐绝热",{"key":24,"text":391,"correct":22},"管道系统试验→系统清洗→防腐绝热",{"key":28,"text":393,"correct":26},"管道及配件安装→系统水压试验、防腐绝热→系统清洗、消毒",{"key":31,"text":395,"correct":22},"防腐绝热→系统清洗→管道系统试验",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":31,"analysis":33},1135509,"钢塑复合管一般使用（ ）连接。",[400,402,404,406],{"key":20,"text":401,"correct":22},"焊接",{"key":24,"text":403,"correct":22},"承插",{"key":28,"text":405,"correct":22},"热熔",{"key":31,"text":407,"correct":26},"螺纹",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":31,"analysis":33},1135510,"室内隐蔽或埋地的（ ）在隐蔽前必须做灌水试验。",[412,414,416,418],{"key":20,"text":413,"correct":22},"热水管道",{"key":24,"text":415,"correct":22},"中水管道",{"key":28,"text":417,"correct":22},"给水管道",{"key":31,"text":419,"correct":26},"排水管道",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":24,"analysis":33},1135511,"阀门安装前，应做强度和严密性试验。试验应在每批（同牌号、同型号、同规格）数量中抽查（ ），且不少于一个",[424,426,428,430],{"key":20,"text":425,"correct":22},"5%",{"key":24,"text":427,"correct":26},"10%",{"key":28,"text":429,"correct":22},"15%",{"key":31,"text":431,"correct":22},"20%",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":31,"analysis":33},1135512,"采暖管道冲洗完毕后应充水、（ ），进行试运行和调试。",[436,437,439,441],{"key":20,"text":185,"correct":22},{"key":24,"text":438,"correct":22},"灌水试验",{"key":28,"text":440,"correct":22},"通球试验",{"key":31,"text":442,"correct":26},"加热",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":20,"analysis":33},1135513,"高层建筑的给水系统和热水系统必须进行合理地竖向分区并加设（ ）。",[447,449,451,453],{"key":20,"text":448,"correct":26},"减压设备",{"key":24,"text":450,"correct":22},"补水装置",{"key":28,"text":452,"correct":22},"补偿装置",{"key":31,"text":454,"correct":22},"阀门",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":28,"analysis":33},1135514,"高层建筑管道采用非镀锌钢管时，一般采用（ ）连接方式。",[459,460,461,462],{"key":20,"text":403,"correct":22},{"key":24,"text":407,"correct":22},{"key":28,"text":401,"correct":26},{"key":31,"text":463,"correct":22},"沟槽",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":28,"analysis":33},1135515,"下列施工工序,建筑室内给水管道安装后的工序是（ ）。",[468,470,472,474],{"key":20,"text":469,"correct":22},"管道元件检验",{"key":24,"text":471,"correct":22},"支架安装",{"key":28,"text":473,"correct":26},"系统水压试验",{"key":31,"text":475,"correct":22},"管道测绘放线",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":28,"analysis":33},1135516,"排水管道主立管及水平干管安装结束后均应做通球试验，通球率达（ ）为合格。",[480,482,484,486],{"key":20,"text":481,"correct":22},"50%",{"key":24,"text":483,"correct":22},"80%",{"key":28,"text":485,"correct":26},"100%",{"key":31,"text":487,"correct":22},"60%",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":20,"analysis":33},1135517,"可用于消防水、空调冷热水、给水、雨水等系统直径大于或等于100mm的镀锌钢管的建筑管道连接方法是（ ）。",[492,494,496,498],{"key":20,"text":493,"correct":26},"沟槽连接",{"key":24,"text":495,"correct":22},"卡套式连接",{"key":28,"text":497,"correct":22},"螺纹连接",{"key":31,"text":499,"correct":22},"卡压连接",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":24,"analysis":33},1135518,"高层建筑对防噪声、防震等要求较高，管道施工应采取必要的隔离、减震或加设（ ）等措施。",[504,506,508,510],{"key":20,"text":505,"correct":22},"刚性连接",{"key":24,"text":507,"correct":26},"柔性连接",{"key":28,"text":509,"correct":22},"法兰连接",{"key":31,"text":511,"correct":22},"承插连接",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":24,"analysis":33},1135519,"冷热水管道上下平行安装时热水管道应在冷水管道（ ）方，垂直安装时热水管道在冷水管道（ ）侧。",[516,518,520,522],{"key":20,"text":517,"correct":22},"上、右",{"key":24,"text":519,"correct":26},"上、左",{"key":28,"text":521,"correct":22},"下、右",{"key":31,"text":523,"correct":22},"下、左",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":20,"analysis":33},1135520,"室内埋地排水管的灌水试验，灌至不低于底层卫生洁具的上边缘，灌水到满水（ ），水面下降后再灌满观察5分钟，液面不降、接口无渗漏为合格。",[528,530,532,534],{"key":20,"text":529,"correct":26},"15min",{"key":24,"text":531,"correct":22},"1h",{"key":28,"text":533,"correct":22},"8h",{"key":31,"text":535,"correct":22},"24h",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":28,"analysis":33},1135521,"排水通气管在经常有人停留的平屋顶上，通气管应高出屋面（ ），并应根据防雷要求，设置防雷装置。",[540,542,544,546],{"key":20,"text":541,"correct":22},"300mm",{"key":24,"text":543,"correct":22},"600mm",{"key":28,"text":545,"correct":26},"2.0m",{"key":31,"text":547,"correct":22},"2.5m",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":28,"analysis":33},1135522,"下列高层建筑管道常用的连接方法中，（ ）一般用在主干道连接阀门、水表、水泵等处，以及需要经常拆卸、检修的管段上。",[552,553,554,555],{"key":20,"text":511,"correct":22},{"key":24,"text":497,"correct":22},{"key":28,"text":509,"correct":26},{"key":31,"text":493,"correct":22},{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":20,"analysis":33},1135523,"阀门的严密性试验压力为（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":26},"公称压力的1.1倍",{"key":24,"text":563,"correct":22},"公称压力的1.15倍",{"key":28,"text":565,"correct":22},"公称压力的1.25倍",{"key":31,"text":567,"correct":22},"公称压力的1.5倍",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":31,"analysis":33},1135524,"安装在主干管上起切断作用的闭路阀门做强度和严密性试验的比例是（ ）。",[572,573,574,576],{"key":20,"text":425,"correct":22},{"key":24,"text":427,"correct":22},{"key":28,"text":575,"correct":22},"30%",{"key":31,"text":485,"correct":26},{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":31,"analysis":33},1135525,"关于导管内穿线的要求，正确的是（）。",[581,583,585,587],{"key":20,"text":582,"correct":22},"绝缘导线穿人金属导管后应装设护线口",{"key":24,"text":584,"correct":22},"绝缘导线接头可以设置在器具和槽盒内",{"key":28,"text":586,"correct":22},"同一回路的导线可穿于不同金属导管内",{"key":31,"text":588,"correct":26},"不同回路绝缘导线不应穿于同一导管内",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":31,"analysis":33},1135526,"下列专用灯具安装，不符合要求的是（）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"投光灯的枢轴沿需要的光轴方向拧紧固定",{"key":24,"text":596,"correct":22},"导轨灯载荷应与导轨最大允许载荷相适配",{"key":28,"text":598,"correct":22},"落地式景观照明灯具距地面的高度为3m",{"key":31,"text":600,"correct":26},"航空障碍标志灯在烟囱顶上装设时，应安装在高于烟囱口1.5~3m的部位",[602,605,608,611,614,617],{"id":15,"name":603,"category":7,"favorite":604},"领导干部任职前廉政法规知识测试题",92,{"id":606,"name":607,"category":7,"favorite":15},595,"建筑结构与设备",{"id":609,"name":610,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":612,"name":613,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":615,"name":616,"category":7,"favorite":8},534,"BIM工程师",{"id":618,"name":616,"category":7,"favorite":8},535]