[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-797-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":732},{"id":5,"name":6,"category":7,"favorite":8},797,"一建机电工程实务","建筑工程",0,32,50,2021,[13,38,53,68,83,97,112,127,142,156,169,183,198,210,224,235,249,264,279,293,308,322,337,348,362,377,391,405,419,434,448,463,477,491,505,519,533,547,561,576,591,605,619,633,647,661,675,689,703,718],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1136906,2,"多选题","塔容器类设备耐压试验前应确认的条件有（）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","试验方案已经编竣",false,{"key":24,"text":25,"correct":26},"B","设备本体及与本体相焊的内件、附件焊接和检验工作全部完成",true,{"key":28,"text":29,"correct":22},"C","在基础上进行耐压试验的设备，基础混凝土强度达到设计强度的75%",{"key":31,"text":32,"correct":26},"D","焊后热处理的设备热处理工作已经完成",{"key":34,"text":35,"correct":26},"E","开孔补强圈焊接接头检查合格","BDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1136907,"通常情况下，容器水压试验合格标准有（）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"地基无沉降",{"key":24,"text":45,"correct":26},"无可见的变形",{"key":28,"text":47,"correct":26},"无渗漏",{"key":31,"text":49,"correct":22},"表面100%磁粉检测无裂纹",{"key":34,"text":51,"correct":26},"试验过程中无异常的响声","BCE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1136908,"锅炉辅助设备主要包括（）等。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"直空气预热器",{"key":24,"text":60,"correct":26},"送引风机",{"key":28,"text":62,"correct":26},"给煤制粉设备",{"key":31,"text":64,"correct":26},"吹灰设备",{"key":34,"text":66,"correct":26},"除灰排渣设备","BCDE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1136909,"转子测量应包括（）。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"轴颈圆度、圆柱度的测量",{"key":24,"text":75,"correct":26},"转子跳动测量",{"key":28,"text":77,"correct":22},"推力盘水平度测量",{"key":31,"text":79,"correct":26},"转子水平度测量",{"key":34,"text":81,"correct":22},"转子气缸找中心测量","ABD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":96,"analysis":37},1136910,"锅炉本体设备主要部件包括（）等。",[87,89,91,92,94],{"key":20,"text":88,"correct":26},"锅炉钢架",{"key":24,"text":90,"correct":22},"送引风设备",{"key":28,"text":62,"correct":22},{"key":31,"text":93,"correct":26},"燃烧器",{"key":34,"text":95,"correct":26},"汽水分离器","ADE",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":111,"analysis":37},1136911,"汽轮发电机主要由（）等组成。",[101,103,105,107,109],{"key":20,"text":102,"correct":26},"定子",{"key":24,"text":104,"correct":22},"再热器",{"key":28,"text":106,"correct":26},"转子",{"key":31,"text":108,"correct":22},"空气预热器",{"key":34,"text":110,"correct":22},"蒸汽系统设备","AC",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":126,"analysis":37},1136912,"锅炉受热面组件吊装的一般原则包括（）。",[116,118,120,122,124],{"key":20,"text":117,"correct":22},"先下后上",{"key":24,"text":119,"correct":22},"先中间后两侧",{"key":28,"text":121,"correct":26},"先上后下",{"key":31,"text":123,"correct":26},"先两侧后中间",{"key":34,"text":125,"correct":22},"上下同时安装","CD",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":141,"analysis":37},1136913,"锅炉受热面施工形式是根据设备的结构特征及现场的施工条件来决定的。组件的组合形式包括（）。",[131,133,135,137,139],{"key":20,"text":132,"correct":22},"分片式",{"key":24,"text":134,"correct":22},"立装式",{"key":28,"text":136,"correct":26},"横卧式",{"key":31,"text":138,"correct":22},"环带式",{"key":34,"text":140,"correct":26},"直立式","CE",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":36,"analysis":37},1136914,"汽轮发电机由定子和转子两部分组成，其中定子主要由（）等部分组成。",[146,148,150,152,154],{"key":20,"text":147,"correct":22},"护环",{"key":24,"text":149,"correct":26},"机座",{"key":28,"text":151,"correct":22},"中心环",{"key":31,"text":153,"correct":26},"端盖",{"key":34,"text":155,"correct":26},"定子铁芯",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":168,"analysis":37},1136915,"锅炉受热面施工形式有（）。",[160,161,163,165,167],{"key":20,"text":140,"correct":26},{"key":24,"text":162,"correct":22},"倾斜式",{"key":28,"text":164,"correct":22},"旋转式",{"key":31,"text":166,"correct":22},"翻转式",{"key":34,"text":136,"correct":26},"AE",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":67,"analysis":37},1136916,"汽轮机按主蒸汽压力可以划分为（）等。",[173,175,177,179,181],{"key":20,"text":174,"correct":22},"凝汽式汽轮机",{"key":24,"text":176,"correct":26},"超高压汽轮机",{"key":28,"text":178,"correct":26},"低压汽轮机",{"key":31,"text":180,"correct":26},"超超临界压力汽轮机",{"key":34,"text":182,"correct":26},"亚临界压力汽轮机",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":197,"analysis":37},1136917,"发电机转子穿装前应单独进行（）。",[187,189,191,193,195],{"key":20,"text":188,"correct":26},"气密性试验",{"key":24,"text":190,"correct":22},"磁道通路试验",{"key":28,"text":192,"correct":26},"漏气量试验",{"key":31,"text":194,"correct":26},"试验压力符合制造厂规定",{"key":34,"text":196,"correct":22},"允许漏气量符合业主要求","ACD",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":209,"analysis":37},1136918,"电站汽轮机主要由（）等组成。",[202,204,205,207,208],{"key":20,"text":203,"correct":26},"汽轮机本体设备",{"key":24,"text":104,"correct":22},{"key":28,"text":206,"correct":26},"其他辅助设备",{"key":31,"text":108,"correct":22},{"key":34,"text":110,"correct":26},"ACE",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":52,"analysis":37},1136919,"1000MW定子的吊装方案中通常采用（）吊装。",[214,216,218,220,222],{"key":20,"text":215,"correct":22},"吊车组合",{"key":24,"text":217,"correct":26},"专用吊装架",{"key":28,"text":219,"correct":26},"行车改装系统",{"key":31,"text":221,"correct":22},"液压顶升平移",{"key":34,"text":223,"correct":26},"液压提升装置",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":67,"analysis":37},1136920,"旋转磁极式发电机转子主要由（）和风扇等组成。",[228,229,231,232,233],{"key":20,"text":149,"correct":22},{"key":24,"text":230,"correct":26},"励磁绕组",{"key":28,"text":147,"correct":26},{"key":31,"text":151,"correct":26},{"key":34,"text":234,"correct":26},"转子锻件",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":248,"analysis":37},1136921,"锅炉蒸汽管路冲洗吹洗的对象包括（）。",[239,241,243,244,246],{"key":20,"text":240,"correct":26},"过热器",{"key":24,"text":242,"correct":26},"过热蒸汽管道",{"key":28,"text":104,"correct":26},{"key":31,"text":245,"correct":22},"凝汽器",{"key":34,"text":247,"correct":26},"减温水管系统","ABCE",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":263,"analysis":37},1136922,"目前国内常规主力电站机组容量为（）。",[253,255,257,259,261],{"key":20,"text":254,"correct":22},"50MW",{"key":24,"text":256,"correct":22},"125MW",{"key":28,"text":258,"correct":22},"300MW（330MW）",{"key":31,"text":260,"correct":26},"600MW（660MW）",{"key":34,"text":262,"correct":26},"1000MW","DE",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":278,"analysis":37},1136923,"电站汽轮机的本体设备中静止部分主要包括（）。",[268,270,272,274,276],{"key":20,"text":269,"correct":26},"隔板套",{"key":24,"text":271,"correct":26},"喷嘴组",{"key":28,"text":273,"correct":22},"主轴",{"key":31,"text":275,"correct":22},"叶轮",{"key":34,"text":277,"correct":26},"汽缸","ABE",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":36,"analysis":37},1136924,"发电机按冷却介质分类，可划分为（）等发电机。",[283,285,287,289,291],{"key":20,"text":284,"correct":22},"固冷",{"key":24,"text":286,"correct":26},"气冷",{"key":28,"text":288,"correct":22},"冰冷却",{"key":31,"text":290,"correct":26},"气液冷",{"key":34,"text":292,"correct":26},"液冷",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":307,"analysis":37},1136925,"轴系对轮中心找正主要是对（）的找正。",[297,299,301,303,305],{"key":20,"text":298,"correct":26},"高中压对轮中心",{"key":24,"text":300,"correct":22},"高压对轮中心",{"key":28,"text":302,"correct":26},"中低压对轮中心",{"key":31,"text":304,"correct":26},"低压对轮中心",{"key":34,"text":306,"correct":26},"低压转子—发电机转子对轮中心","ACDE",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":96,"analysis":37},1136926,"汽轮机隔板安装时找中心的方法有（）。",[312,314,316,318,320],{"key":20,"text":313,"correct":26},"假轴找中心",{"key":24,"text":315,"correct":22},"定子找中心",{"key":28,"text":317,"correct":22},"转子找中心",{"key":31,"text":319,"correct":26},"拉钢丝找中心",{"key":34,"text":321,"correct":26},"激光准直仪找中心",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":336,"analysis":37},1136927,"凝汽器组装完毕后，汽侧灌水试验的工作内容有（）。",[326,328,330,332,334],{"key":20,"text":327,"correct":26},"灌水高度应充满整个冷却管的汽侧空间并高出顶部冷却管100mm",{"key":24,"text":329,"correct":26},"维持24h无渗漏",{"key":28,"text":331,"correct":26},"增加临时支撑",{"key":31,"text":333,"correct":26},"及时将水放净",{"key":34,"text":335,"correct":22},"水放净后烘干","ABCD",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":336,"analysis":37},1136928,"电站锅炉系统的锅炉本体主要由炉膛、燃烧器和（）等部件构成。",[341,343,344,345,347],{"key":20,"text":342,"correct":26},"水冷壁",{"key":24,"text":104,"correct":26},{"key":28,"text":108,"correct":26},{"key":31,"text":346,"correct":26},"省煤器",{"key":34,"text":62,"correct":22},{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":82,"analysis":37},1136929,"自动化仪表安装的施工准备阶段工作是保证工程顺利进行的重要环节，其主要工作内容包括（）。",[352,354,356,358,360],{"key":20,"text":353,"correct":26},"参加施工图设计文件会审",{"key":24,"text":355,"correct":26},"编制施工预算",{"key":28,"text":357,"correct":22},"各控制室布置",{"key":31,"text":359,"correct":26},"工机具和标准仪器的准备",{"key":34,"text":361,"correct":22},"编制施工进度计划",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":376,"analysis":37},1136930,"下列自动化仪表线路的敷设，正确的有（）。",[366,368,370,372,374],{"key":20,"text":367,"correct":22},"敷设在高温管道上方200mm",{"key":24,"text":369,"correct":22},"敷设在腐蚀性液体管道下方300mm",{"key":28,"text":371,"correct":26},"与绝热的设备之间距离300mm",{"key":31,"text":373,"correct":26},"与管道绝热层之间距离200mm",{"key":34,"text":375,"correct":26},"与排水管道之间距离150mm","CDE",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":336,"analysis":37},1136931,"关于自动化工程的控制阀和执行机构试验的说法，正确的有（）。",[381,383,385,387,389],{"key":20,"text":382,"correct":26},"阀体压力试验可以对制造厂出具的产品合格证明进行验证",{"key":24,"text":384,"correct":26},"事故切断阀应进行阀座的密封试验",{"key":28,"text":386,"correct":26},"进行缸体泄漏性试验以及行程试验",{"key":31,"text":388,"correct":26},"事故切断阀应进行全行程时间试验",{"key":34,"text":390,"correct":22},"执行机构在试验时调整到最大状态",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":82,"analysis":37},1136932,"关于自动化仪表系统，说法正确的有（）。",[395,397,399,401,403],{"key":20,"text":396,"correct":26},"电缆电线敷设前，应进行外观检查和导通检查，并应用兆欧表测量绝缘电阻，其绝缘电阻值不应小于5兆欧",{"key":24,"text":398,"correct":26},"当线路周围环境温度超过65摄氏度时应采取隔热措施；当线路附近有火源时，应采用防火措施",{"key":28,"text":400,"correct":22},"线路不得敷设在易受机械损伤，但可敷设强静电场干扰的位置",{"key":31,"text":402,"correct":26},"线路不得敷设在影响操作和妨碍设备，管道检修的位置，应避开运输，人行通道和吊装孔",{"key":34,"text":404,"correct":22},"线路的终端接线处及经达建筑物的伸缩缝和沉降缝处不应留有余度",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":111,"analysis":37},1136933,"关于DCS机柜的接地要求，正确的有（）。",[409,411,413,415,417],{"key":20,"text":410,"correct":26},"DCS机柜需单独接地",{"key":24,"text":412,"correct":22},"接地点到防雷接地距离需大于5m",{"key":28,"text":414,"correct":26},"机柜与底座间铺设绝缘材料",{"key":31,"text":416,"correct":22},"总接地电阻小于4Ω",{"key":34,"text":418,"correct":22},"机柜与底座连接螺栓选用镀锌店垫片",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":433,"analysis":37},1136934,"自动化仪表工程的温度取源部件在管道上开孔及焊接，必须在管道（）前进行。",[423,425,427,429,431],{"key":20,"text":424,"correct":22},"制作",{"key":24,"text":426,"correct":26},"防腐",{"key":28,"text":428,"correct":26},"衬里",{"key":31,"text":430,"correct":26},"压力试验",{"key":34,"text":432,"correct":22},"安装","BCD",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":82,"analysis":37},1136935,"自动化仪表线路碰到管道的敷设要求（）。",[438,440,442,444,446],{"key":20,"text":439,"correct":26},"不宜敷设在高温管道的上方",{"key":24,"text":441,"correct":26},"不宜敷设在具有腐蚀性液体管道的下方",{"key":28,"text":443,"correct":22},"不应敷设在高温管道的下方",{"key":31,"text":445,"correct":26},"与管道绝热层之间的最小距离应≥200mm",{"key":34,"text":447,"correct":22},"与其他设备之间的最小距离应≥100mm",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":462,"analysis":37},1136936,"自动化仪表的取源部件安装完毕后，应随同（）进行压力试验。",[452,454,456,458,460],{"key":20,"text":453,"correct":26},"工艺设备",{"key":24,"text":455,"correct":26},"工艺管道",{"key":28,"text":457,"correct":22},"仪表设备",{"key":31,"text":459,"correct":22},"控制仪表",{"key":34,"text":461,"correct":22},"显示仪表","AB",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":82,"analysis":37},1136937,"自动化仪表设备安装工程中，取源部件安装的一般规定是（）。",[467,469,471,473,475],{"key":20,"text":468,"correct":26},"设备上的取源部件应在设备制造的同时安装",{"key":24,"text":470,"correct":26},"管道上的取源部件应在管道预制、安装的同时安装",{"key":28,"text":472,"correct":22},"在管道上安装取源部件的开孔和焊接工作，必须在管道的防腐、衬里和压力试验后进行",{"key":31,"text":474,"correct":26},"在砌体和混凝土浇筑体上安装取源部件，应在砌筑或浇筑的同时埋入，当无法同时安装时，应预留安装孔",{"key":34,"text":476,"correct":22},"取源部件安装完毕后，应随同管道一起进行灌水试验",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":126,"analysis":37},1136938,"仪表设备安装的规定包括（）。",[481,483,485,487,489],{"key":20,"text":482,"correct":22},"仪表盘、柜、操作台之间的安装固定可采用焊接",{"key":24,"text":484,"correct":22},"压力式温度计的温包不能全部浸入被测对象中",{"key":28,"text":486,"correct":26},"测量高压的压力表安装在操作岗位附近时,仪表正面应加保护罩",{"key":31,"text":488,"correct":26},"浮筒液位计的安装应使浮筒呈垂直状态",{"key":34,"text":490,"correct":22},"超声波物位计和雷达物位计应安装在进料口的上方",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":197,"analysis":37},1136939,"自动化仪表试验的电源电压要求有（）。",[495,497,499,501,503],{"key":20,"text":496,"correct":26},"交流电源电压波动不应超过±10%",{"key":24,"text":498,"correct":22},"60V以上的直流电源电压波动不应超过±5%",{"key":28,"text":500,"correct":26},"60V以上的直流电源电压波动不应超过±10%",{"key":31,"text":502,"correct":26},"60V以下的直流电源电压波动不应超过±5%",{"key":34,"text":504,"correct":22},"60V以下的直流电源电压波动不应超过±10%",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":462,"analysis":37},1136940,"测量蒸汽压力的压力取源部件应安装在管道的（）。",[509,511,513,515,517],{"key":20,"text":510,"correct":26},"管道的上半部",{"key":24,"text":512,"correct":26},"下半部与管道水平中心线成0~45°夹角范围内",{"key":28,"text":514,"correct":22},"管道的下半部",{"key":31,"text":516,"correct":22},"下半部与管道水平中心线成45~90°夹角范围内",{"key":34,"text":518,"correct":22},"下半部与管道水平中心线成45~60°夹角范围内",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":248,"analysis":37},1136941,"仪表施工技术交底应明确（）等具体的技术要求。",[523,525,527,529,531],{"key":20,"text":524,"correct":26},"施工工艺",{"key":24,"text":526,"correct":26},"安全措施",{"key":28,"text":528,"correct":26},"施工程序",{"key":31,"text":530,"correct":22},"项目介绍",{"key":34,"text":532,"correct":26},"技术质量要求",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":433,"analysis":37},1136942,"自动化仪表工程的温度取源部件在管道上开孔及焊接前不应做的工作有（）。",[537,539,541,543,545],{"key":20,"text":538,"correct":22},"管道制作",{"key":24,"text":540,"correct":26},"管道防腐",{"key":28,"text":542,"correct":26},"管道衬里",{"key":31,"text":544,"correct":26},"管道试压",{"key":34,"text":546,"correct":22},"管道固定",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":209,"analysis":37},1136943,"自动化仪表工程的验收分为（）步骤进行。",[551,553,555,557,559],{"key":20,"text":552,"correct":26},"分项工程验收",{"key":24,"text":554,"correct":22},"隐蔽工程验收",{"key":28,"text":556,"correct":26},"分部工程验收",{"key":31,"text":558,"correct":22},"检验批",{"key":34,"text":560,"correct":26},"单位工程竣工验收",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":575,"analysis":37},1136944,"自动化仪表的电缆敷设前应进行的检查有（）。",[565,567,569,571,573],{"key":20,"text":566,"correct":26},"绝缘电阻测试",{"key":24,"text":568,"correct":26},"外观检查",{"key":28,"text":570,"correct":26},"导通检查",{"key":31,"text":572,"correct":22},"光通损耗",{"key":34,"text":574,"correct":22},"光纤衰减","ABC",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":590,"analysis":37},1136945,"下列测量管道的安装，正确的有（）。",[580,582,584,586,588],{"key":20,"text":581,"correct":26},"测量管道水平敷设时，有1:10~1:100的坡度",{"key":24,"text":583,"correct":26},"在管道的集气处安装排气装置，在集液处安装排液装置",{"key":28,"text":585,"correct":22},"测量管道与工艺管道距离不得小于150mm",{"key":31,"text":587,"correct":26},"测量管道与高温设备连接应采取热膨胀补偿措施",{"key":34,"text":589,"correct":26},"薄壁测量管道严禁使用钢印作标识","ABDE",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":307,"analysis":37},1136946,"温度取源部件的安装，（）。",[595,597,599,601,603],{"key":20,"text":596,"correct":26},"与管道呈倾斜角度安装时，宜逆着物料流向，取源部件轴线应与管道轴线相交",{"key":24,"text":598,"correct":22},"如果需在焊缝上开孔，应打磨平滑",{"key":28,"text":600,"correct":26},"在管道的拐弯处安装时，宜逆着物料流向",{"key":31,"text":602,"correct":26},"温度取源部件与管道垂直安装时，取源部件轴线应与管道轴线相垂直",{"key":34,"text":604,"correct":26},"取源部件安装在扩大管上时，扩大管的安装方式应符合设计文件的规定",{"id":606,"libraryId":5,"type":15,"typeLabel":16,"stem":607,"options":608,"answer":336,"analysis":37},1136947,"自动化线路敷设完毕后，应进行的工作有（）。",[609,611,613,615,617],{"key":20,"text":610,"correct":26},"校线",{"key":24,"text":612,"correct":26},"标号",{"key":28,"text":614,"correct":26},"埋设的线路应设置明显标识",{"key":31,"text":616,"correct":26},"测量电缆电线的绝缘电阻",{"key":34,"text":618,"correct":22},"在线路的起端处加标志牌",{"id":620,"libraryId":5,"type":15,"typeLabel":16,"stem":621,"options":622,"answer":376,"analysis":37},1136948,"关于流量取源部件安装的要求，正确的有（）。",[623,625,627,629,631],{"key":20,"text":624,"correct":22},"上游侧取压孔与孔板距离为16mm",{"key":24,"text":626,"correct":22},"下游侧取压孔与孔板距离为16mm",{"key":28,"text":628,"correct":26},"取压孔的直径为8mm",{"key":31,"text":630,"correct":26},"上下游侧取压孔直径相等",{"key":34,"text":632,"correct":26},"取压孔轴线与管道轴线垂直相交",{"id":634,"libraryId":5,"type":15,"typeLabel":16,"stem":635,"options":636,"answer":376,"analysis":37},1136949,"强制电流阴极保护系统由（）组成。",[637,639,641,643,645],{"key":20,"text":638,"correct":22},"交流电源",{"key":24,"text":640,"correct":22},"辅助阴极",{"key":28,"text":642,"correct":26},"辅助阳极",{"key":31,"text":644,"correct":26},"直流电源",{"key":34,"text":646,"correct":26},"附属设施",{"id":648,"libraryId":5,"type":15,"typeLabel":16,"stem":649,"options":650,"answer":82,"analysis":37},1136950,"表面处理清洁度达到Sa2级方可施工的有（）。",[651,653,655,657,659],{"key":20,"text":652,"correct":26},"涂料涂层",{"key":24,"text":654,"correct":26},"水玻璃胶泥衬砌砖板衬里",{"key":28,"text":656,"correct":22},"橡胶衬里",{"key":31,"text":658,"correct":26},"氯丁胶乳水泥砂浆衬里",{"key":34,"text":660,"correct":22},"纤维增强塑料衬里",{"id":662,"libraryId":5,"type":15,"typeLabel":16,"stem":663,"options":664,"answer":141,"analysis":37},1136951,"块材衬里若采用胶泥衬砌法施工时，常用的胶泥材料有（）。",[665,667,669,671,673],{"key":20,"text":666,"correct":22},"沥青漆",{"key":24,"text":668,"correct":22},"聚氯乙烯",{"key":28,"text":670,"correct":26},"水玻璃",{"key":31,"text":672,"correct":22},"氯丁乳胶",{"key":34,"text":674,"correct":26},"树脂",{"id":676,"libraryId":5,"type":15,"typeLabel":16,"stem":677,"options":678,"answer":248,"analysis":37},1136952,"纤维增强塑料衬里的施工方法有（）。",[679,681,683,685,687],{"key":20,"text":680,"correct":26},"手工糊制作",{"key":24,"text":682,"correct":26},"间断法",{"key":28,"text":684,"correct":26},"连续法",{"key":31,"text":686,"correct":22},"粘接法",{"key":34,"text":688,"correct":26},"喷射法",{"id":690,"libraryId":5,"type":15,"typeLabel":16,"stem":691,"options":692,"answer":433,"analysis":37},1136953,"塑料衬里若采用氟塑料板成型，宜选用的方法有（）。",[693,695,697,699,701],{"key":20,"text":694,"correct":22},"粘贴法",{"key":24,"text":696,"correct":26},"热风焊",{"key":28,"text":698,"correct":26},"挤出焊",{"key":31,"text":700,"correct":26},"热压焊",{"key":34,"text":702,"correct":22},"松衬法",{"id":704,"libraryId":5,"type":15,"typeLabel":16,"stem":705,"options":706,"answer":717,"analysis":37},1136954,"关于金属热喷涂分层喷涂的说法，正确的有（）。",[707,709,711,713,715],{"key":20,"text":708,"correct":22},"设计厚度不得大于等于0.1mm",{"key":24,"text":710,"correct":26},"喷涂的每一层均应平行搭接",{"key":28,"text":712,"correct":22},"同层涂层喷涂方向应纵横交叉",{"key":31,"text":714,"correct":26},"上下两层的喷涂方向应纵横交叉",{"key":34,"text":716,"correct":22},"喷涂作业时不得降低热源功率","BD",{"id":719,"libraryId":5,"type":15,"typeLabel":16,"stem":720,"options":721,"answer":590,"analysis":37},1136955,"目前常用的金属热喷涂材料有（）",[722,724,726,728,730],{"key":20,"text":723,"correct":26},"锌",{"key":24,"text":725,"correct":26},"铝",{"key":28,"text":727,"correct":22},"铁合金",{"key":31,"text":729,"correct":26},"锌铝合金",{"key":34,"text":731,"correct":26},"铝镁合金",[733,737,740,743,746,749],{"id":734,"name":735,"category":7,"favorite":736},1,"领导干部任职前廉政法规知识测试题",92,{"id":738,"name":739,"category":7,"favorite":734},595,"建筑结构与设备",{"id":741,"name":742,"category":7,"favorite":734},715,"招标采购专业知识与法律法规",{"id":744,"name":745,"category":7,"favorite":734},848,"市政方向-通用基础",{"id":747,"name":748,"category":7,"favorite":8},534,"BIM工程师",{"id":750,"name":748,"category":7,"favorite":8},535]