[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-797-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":739},{"id":5,"name":6,"category":7,"favorite":8},797,"一建机电工程实务","建筑工程",0,29,50,2021,[13,38,53,68,82,96,110,125,137,152,167,182,196,211,226,240,254,268,283,298,313,328,342,356,371,385,399,413,427,441,455,469,483,497,511,525,539,554,569,584,599,613,627,641,655,669,683,697,711,725],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1136754,2,"多选题","预防焊接变形的装配工艺措施（）",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","合理的焊接线能量",false,{"key":24,"text":25,"correct":26},"B","预留收缩余量",true,{"key":28,"text":29,"correct":22},"C","合理安排焊缝位置",{"key":31,"text":32,"correct":26},"D","合理选择装配程序",{"key":34,"text":35,"correct":26},"E","刚性固定","BDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1136755,"焊评试件检验项目至少应包括（）",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"外观检查",{"key":24,"text":45,"correct":26},"无损检测",{"key":28,"text":47,"correct":26},"力学性能试验",{"key":31,"text":49,"correct":26},"弯曲试验",{"key":34,"text":51,"correct":22},"焊条的酸碱性","ABCD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1136756,"下列焊接残余变形中属于面外变形的有（）。",[57,59,61,63,65],{"key":20,"text":58,"correct":26},"弯曲变形",{"key":24,"text":60,"correct":26},"扭曲变形",{"key":28,"text":62,"correct":22},"焊缝回转变形",{"key":31,"text":64,"correct":26},"失稳波浪变形",{"key":34,"text":66,"correct":22},"焊缝纵向收缩变形","ABD",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":67,"analysis":37},1136757,"焊接用气体的选择主要取决于（ ）因素有关。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"焊接方法",{"key":24,"text":75,"correct":26},"焊件厚度",{"key":28,"text":77,"correct":22},"焊接人员",{"key":31,"text":79,"correct":26},"焊接工艺",{"key":34,"text":81,"correct":22},"焊接材料",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":67,"analysis":37},1136758,"钢结构所用焊接材料应按到货批次进行复验的情况有（ ）。",[86,88,90,92,94],{"key":20,"text":87,"correct":26},"建筑结构安全等级为二级的一级焊缝",{"key":24,"text":89,"correct":26},"建筑结构安全等级为一级的二级焊缝",{"key":28,"text":91,"correct":22},"大跨度的二级焊缝",{"key":31,"text":93,"correct":26},"重级工作制吊车梁结构中的一级焊缝",{"key":34,"text":95,"correct":22},"建筑结构安全等级为二级的二级焊缝",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":67,"analysis":37},1136759,"下列关于焊接工艺评定说法正确的是（ ）。",[100,102,104,106,108],{"key":20,"text":101,"correct":26},"用于验证拟定的焊接工艺的正确性",{"key":24,"text":103,"correct":26},"用于验证施焊单位的能力",{"key":28,"text":105,"correct":22},"评定报告可直接指导生产",{"key":31,"text":107,"correct":26},"是焊接工艺卡的支持文件",{"key":34,"text":109,"correct":22},"一个焊接工艺评定报告只是编制一份焊接工艺规程的依据",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":124,"analysis":37},1136760,"降低焊接应力的正确措施有（ ）。",[114,116,118,120,122],{"key":20,"text":115,"correct":26},"构件设计时尽量减少焊缝尺寸",{"key":24,"text":117,"correct":22},"将焊缝集中在一个区域",{"key":28,"text":119,"correct":26},"焊接时采用较小的焊接线能量",{"key":31,"text":121,"correct":22},"焊接过程中，层间锤击",{"key":34,"text":123,"correct":26},"焊接前对构件进行整体预热","ACE",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":136,"analysis":37},1136761,"下列焊接变形中不属于面内变形的是（ ）。",[129,131,132,133,134],{"key":20,"text":130,"correct":22},"横向收缩变形",{"key":24,"text":60,"correct":26},{"key":28,"text":62,"correct":22},{"key":31,"text":58,"correct":26},{"key":34,"text":135,"correct":22},"纵向收缩变形","BD",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":151,"analysis":37},1136762,"建筑管道的安装工程中，当镀锌钢管管径大于DN100时，可采用（ ）连接。",[141,143,145,147,149],{"key":20,"text":142,"correct":22},"承插",{"key":24,"text":144,"correct":22},"热熔连接",{"key":28,"text":146,"correct":26},"法兰",{"key":31,"text":148,"correct":26},"沟槽",{"key":34,"text":150,"correct":22},"焊接","CD",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":166,"analysis":37},1136763,"供暖管道冲洗完毕后，应（ ），进行试运行和调试。",[156,158,160,162,164],{"key":20,"text":157,"correct":22},"试压",{"key":24,"text":159,"correct":26},"充水",{"key":28,"text":161,"correct":22},"通球",{"key":31,"text":163,"correct":22},"灌水",{"key":34,"text":165,"correct":26},"加热","BE",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":181,"analysis":37},1136764,"建筑管道安装一般应本着（ ）的原则进行。",[171,173,175,177,179],{"key":20,"text":172,"correct":26},"先主管、后支管",{"key":24,"text":174,"correct":22},"先支管、后主管",{"key":28,"text":176,"correct":22},"先下部、后上部",{"key":31,"text":178,"correct":26},"先上部、后下部",{"key":34,"text":180,"correct":26},"先里后外","ADE",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":181,"analysis":37},1136765,"管道穿过墙壁和楼板时的套管设置，正确的有（ ）。",[186,188,190,192,194],{"key":20,"text":187,"correct":26},"楼板内套管高出装饰地面20mm",{"key":24,"text":189,"correct":22},"楼板内套管高出装饰地面50mm",{"key":28,"text":191,"correct":22},"卫生间内套管高出装饰地面20mm",{"key":31,"text":193,"correct":26},"卫生间内套管高出装饰地面50mm",{"key":34,"text":195,"correct":26},"安装在墙壁内套管两端与饰面齐平",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":210,"analysis":37},1136766,"下列核定内容中，在安装水泵时应认真核定的有（ ）。",[200,202,204,206,208],{"key":20,"text":201,"correct":26},"流量",{"key":24,"text":203,"correct":26},"扬程",{"key":28,"text":205,"correct":26},"配用电机功率",{"key":31,"text":207,"correct":22},"供货单位",{"key":34,"text":209,"correct":22},"进场时间","ABC",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":225,"analysis":37},1136767,"高层建筑管道工程采取的防震降噪的保证措施有（ ）。",[215,217,219,221,223],{"key":20,"text":216,"correct":26},"水泵与基础间加设橡胶垫隔离",{"key":24,"text":218,"correct":26},"管路中加装柔性连接",{"key":28,"text":220,"correct":22},"给水系统中加设减压设备",{"key":31,"text":222,"correct":22},"管道增设支吊架",{"key":34,"text":224,"correct":22},"减少给水系统管路的连接件","AB",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":225,"analysis":37},1136768,"在不赶工的前提下，高层住宅给水排水及室内雨落管道应在（ ）后，再穿外墙做出户管道。",[230,232,234,236,238],{"key":20,"text":231,"correct":26},"结构封顶",{"key":24,"text":233,"correct":26},"初沉降",{"key":28,"text":235,"correct":22},"室内管道安装",{"key":31,"text":237,"correct":22},"室内管道试压",{"key":34,"text":239,"correct":22},"室内管道防腐施工",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":52,"analysis":37},1136769,"建筑电气工程中，柔性导管敷设的要求有（）。",[244,246,248,250,252],{"key":20,"text":245,"correct":26},"柔性导管的长度在动力工程中不宜大于0.8m",{"key":24,"text":247,"correct":26},"柔性导管的长度在照明工程中不宜大于1.2m",{"key":28,"text":249,"correct":26},"柔性导管与刚性导管的连接应采用专用接头",{"key":31,"text":251,"correct":26},"金属柔性导管不应作为保护导体的连续导体",{"key":34,"text":253,"correct":22},"埋设在混凝土内的导管可采用金属柔性导管",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":52,"analysis":37},1136770,"一个8层建筑（33m高）防雷工程的分项工程内容有（）。",[258,260,262,264,266],{"key":20,"text":259,"correct":26},"避雷带安装",{"key":24,"text":261,"correct":26},"均压环安装",{"key":28,"text":263,"correct":26},"引下线安装",{"key":31,"text":265,"correct":26},"接地体安装",{"key":34,"text":267,"correct":22},"等电位安装",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":282,"analysis":37},1136771,"灯具安装的技术要求有（）。",[272,274,276,278,280],{"key":20,"text":273,"correct":22},"消防应急灯具应获得消防产品型式自检合格即可，无需认证标志",{"key":24,"text":275,"correct":26},"疏散指示标志灯具的保护罩应完整、无裂纹",{"key":28,"text":277,"correct":26},"水下灯及防水灯具的防护等级应符合设计要求，当对其密闭和绝缘性能有异议时，应按批抽样送有资质的试验室检测",{"key":31,"text":279,"correct":26},"灯具内部接线应为铜芯绝缘导线，其截面应与灯具功率相匹配，且不应小于0.5mm2",{"key":34,"text":281,"correct":22},"固定灯具带电部件及提供防触电保护的部位应为需用电工胶布包裹，不一定为绝缘材料","BCD",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":297,"analysis":37},1136772,"建筑电气工程中，槽盒内的敷线要求有（）。",[287,289,291,293,295],{"key":20,"text":288,"correct":22},"同一槽盒可同时敷设绝缘导线和电力电缆",{"key":24,"text":290,"correct":26},"同一路径无抗干扰要求的线路可敷设于同一槽盒内",{"key":28,"text":292,"correct":26},"槽盒内的绝缘导线截面不应超过槽盒内截面的40%",{"key":31,"text":294,"correct":22},"槽盒内的绝缘导线的根数不宜超过50根",{"key":34,"text":296,"correct":26},"非电力绝缘导线的总截面不应超过槽盒内截面的50%","BCE",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":312,"analysis":37},1136773,"建筑电气工程中，母线槽的安装连接要求有（）。",[302,304,306,308,310],{"key":20,"text":303,"correct":26},"配电母线槽水平度偏差不宜大于1.5‰",{"key":24,"text":305,"correct":22},"照明母线槽水平偏差全长不应大于10㎜",{"key":28,"text":307,"correct":26},"照明母线槽垂直偏差全长不应大于10㎜",{"key":31,"text":309,"correct":26},"母线应与外壳同心，允许偏差应为±5㎜",{"key":34,"text":311,"correct":22},"母线槽直线敷设长度超过50m设置伸缩节","ACD",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":327,"analysis":37},1136774,"下列照明灯具的安装固定，正确的有（）。",[317,319,321,323,325],{"key":20,"text":318,"correct":22},"在混凝土楼板结构上使用塑料塞固定灯具",{"key":24,"text":320,"correct":22},"100kg灯具的悬吊装置按灯具重量的3倍做强度试验",{"key":28,"text":322,"correct":26},"质量大于3㎏的悬吊灯具，固定在螺栓或预埋吊钩上，螺栓或预埋吊钩的直径不应小于灯具挂销直径，且不应小于6㎜",{"key":31,"text":324,"correct":26},"混凝土墙面上用2个固定螺钉安装灯具",{"key":34,"text":326,"correct":26},"质量大于0.5kg的软线吊灯，灯具的电源线不应受力。","CDE",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":124,"analysis":37},1136775,"关于灯具现场检查要求的说法,正确的是（）。",[332,334,336,338,340],{"key":20,"text":333,"correct":26},"I类灯具外壳有专用的PE端子",{"key":24,"text":335,"correct":22},"消防应急灯具有试验标志",{"key":28,"text":337,"correct":26},"灯具内部接线为铜芯绝缘导线",{"key":31,"text":339,"correct":22},"灯具绝缘电阻不小于0.5兆欧",{"key":34,"text":341,"correct":26},"导线绝缘层厚度不小于0.6毫米",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":67,"analysis":37},1136776,"关于照明系统的测试和通电试运行的说法，正确的有（）。",[346,348,350,352,354],{"key":20,"text":347,"correct":26},"导线绝缘电阻测试应在导线接续前完成",{"key":24,"text":349,"correct":26},"灯具的绝缘电阻测试应在器具就位前完成",{"key":28,"text":351,"correct":22},"照明配电箱绝缘电阻测试应在接线后完成",{"key":31,"text":353,"correct":26},"照明回路剩余电流动作保护器应检测合格",{"key":34,"text":355,"correct":22},"应急照明电源做自动投切试验应卸除负荷",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":370,"analysis":37},1136777,"下列工序中，属于动力设备施工工序的有（）。",[360,362,364,366,368],{"key":20,"text":361,"correct":22},"配电箱安装",{"key":24,"text":363,"correct":26},"电动机检查",{"key":28,"text":365,"correct":26},"控制设备安装",{"key":31,"text":367,"correct":26},"电动机接线",{"key":34,"text":369,"correct":26},"送电前的检查","BCDE",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":210,"analysis":37},1136778,"变配电室分项工程组成包括（）",[375,377,379,381,383],{"key":20,"text":376,"correct":26},"裸母线、封闭母线、插接式母线安装",{"key":24,"text":378,"correct":26},"控制柜安装",{"key":28,"text":380,"correct":26},"变压器",{"key":31,"text":382,"correct":22},"柴油发电机组",{"key":34,"text":384,"correct":22},"UPS设备",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":297,"analysis":37},1136779,"建筑电气工程中，金属槽盒安装的要求有（）。",[389,391,393,395,397],{"key":20,"text":390,"correct":22},"配线槽盒宜安装在冷水管的下方",{"key":24,"text":392,"correct":26},"配线槽盒应敷设在热水管的下方",{"key":28,"text":394,"correct":26},"穿越防火区的槽盒应有防火措施",{"key":31,"text":396,"correct":22},"60m槽盒有2处与保护导体连接",{"key":34,"text":398,"correct":26},"起始端和终点端均应可靠地接地",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":67,"analysis":37},1136780,"建筑电气工程中，接闪带的安装要求有（）。",[403,405,407,409,411],{"key":20,"text":404,"correct":26},"接闪带的固定支架高度不宜小于150mm",{"key":24,"text":406,"correct":26},"每个固定支架应能承受49N的垂直拉力",{"key":28,"text":408,"correct":22},"镀锌扁钢接闪带的连接应采用螺栓搭接",{"key":31,"text":410,"correct":26},"接闪带在变形缝处的跨接应有补偿措施",{"key":34,"text":412,"correct":22},"接闪带与防雷引下线必须采用焊接连接",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":327,"analysis":37},1136781,"下列通风空调工程阀门、部件安装，说法正确的是（）。",[417,419,421,423,425],{"key":20,"text":418,"correct":22},"除尘系统吸入管段调节阀安装在水平管段",{"key":24,"text":420,"correct":22},"部件可以随意安装",{"key":28,"text":422,"correct":26},"长边大于630mm的防火阀设独立支架",{"key":31,"text":424,"correct":26},"钢索预埋套管弯管不应大于2个",{"key":34,"text":426,"correct":26},"风阀安装在便于操作及维修的部位",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":370,"analysis":37},1136782,"下列工序中，属于金属风管安装工序的有（）。",[431,433,435,437,439],{"key":20,"text":432,"correct":22},"风管加固",{"key":24,"text":434,"correct":26},"风管检查",{"key":28,"text":436,"correct":26},"风管调整",{"key":31,"text":438,"correct":26},"支吊架定位安装",{"key":34,"text":440,"correct":26},"漏风量测试",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":124,"analysis":37},1136783,"关于通风与空调工程防排烟系统的柔性短管要求的说法，正确的有（）。",[445,447,449,451,453],{"key":20,"text":446,"correct":26},"柔性短管必须为不燃材料",{"key":24,"text":448,"correct":22},"采用防潮及透气的柔性材料",{"key":28,"text":450,"correct":26},"柔性短管长度宜为150~250mm",{"key":31,"text":452,"correct":22},"柔性短管可以做成异径连接管",{"key":34,"text":454,"correct":26},"柔性短管与法兰组装宜采用压板铆接连接",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":370,"analysis":37},1136784,"关于冷却塔的要求，正确的有（）。",[459,461,463,465,467],{"key":20,"text":460,"correct":22},"冷却塔与基座的连接必须用不锈钢螺栓",{"key":24,"text":462,"correct":26},"冷却塔的水平度和垂直度允许偏差为2‰",{"key":28,"text":464,"correct":26},"多台开式冷却塔的水面高度应一致，高度偏差值不应大于30mm",{"key":31,"text":466,"correct":26},"冷却塔进风侧距建筑物应大于1m",{"key":34,"text":468,"correct":26},"标高应符合设计要求，允许误差应为±20mm",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":282,"analysis":37},1136785,"在矩形风管无法兰连接中，适用于中压风管连接的是（）。",[473,475,477,479,481],{"key":20,"text":474,"correct":22},"S型插条",{"key":24,"text":476,"correct":26},"C型插条",{"key":28,"text":478,"correct":26},"薄钢管法兰插条",{"key":31,"text":480,"correct":26},"薄钢板法兰弹簧夹",{"key":34,"text":482,"correct":22},"直角形平插条",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":282,"analysis":37},1136786,"下列加固形式中，可以用于风管的内支撑加固的有（）。",[487,489,491,493,495],{"key":20,"text":488,"correct":22},"角钢内支撑",{"key":24,"text":490,"correct":26},"扁钢内支撑",{"key":28,"text":492,"correct":26},"镀锌螺杆内支撑",{"key":31,"text":494,"correct":26},"钢管内支撑",{"key":34,"text":496,"correct":22},"槽钢内支撑",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":297,"analysis":37},1136787,"关于多联机组的制冷剂管道及管件安装要求，正确的有（）。",[501,503,505,507,509],{"key":20,"text":502,"correct":22},"制冷剂管道弯管的弯曲半径不应小于2.5倍管道直径",{"key":24,"text":504,"correct":26},"最大外径与最小外径之差不应大于0.08倍管道直径，且不应使用焊接弯管及皱褶弯管",{"key":28,"text":506,"correct":26},"制冷剂管道的分支管应按介质流向弯成90°与主管连接",{"key":31,"text":508,"correct":22},"采用对接焊接的铜管管道错边量不应大于0.2倍壁厚",{"key":34,"text":510,"correct":26},"采用承插钎焊连接的铜管承口应迎着介质流动方向",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":36,"analysis":37},1136788,"关于通风空调系统联合试运转及调试的说法，正确的有（）。",[515,517,519,521,523],{"key":20,"text":516,"correct":22},"系统总风量调试结果与设计风量的允许偏差不应大于15%",{"key":24,"text":518,"correct":26},"各风口及吸风罩的风量与设计流量的允许偏差不应大于15%",{"key":28,"text":520,"correct":22},"空调冷（热）水系统的总流量与设计流量的偏差不应大于15%",{"key":31,"text":522,"correct":26},"变流量系统的各空气处理机组的水流量允许偏差应为10%",{"key":34,"text":524,"correct":26},"制冷机及冷却塔的水流量与设计流量的偏差不应大于10%",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":36,"analysis":37},1136789,"关于风管安装的要求，正确的有（）。",[529,531,533,535,537],{"key":20,"text":530,"correct":22},"风管接口的配置应根据现场安装位置精度缩小其有效截面",{"key":24,"text":532,"correct":26},"法兰的连接螺栓的螺母宜在同一侧",{"key":28,"text":534,"correct":22},"风管法兰的垫片厚度不应小于2.5mm",{"key":31,"text":536,"correct":26},"风管与混凝土风道的接口应顺着气流方向插入",{"key":34,"text":538,"correct":26},"明装风管的水平度的允许偏差应为3‰",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":553,"analysis":37},1136790,"关于净化空调系统中风管制作的要求有（）。",[543,545,547,549,551],{"key":20,"text":544,"correct":22},"宜采用镀锌层厚度小于100g\u002F㎡镀锌钢板",{"key":24,"text":546,"correct":26},"净化空调风管内不得设有加固框或加固筋",{"key":28,"text":548,"correct":26},"矩形风管咬口缝处所涂密封胶宜在正压侧",{"key":31,"text":550,"correct":22},"矩形风管使用S型插条及直角形插条连接",{"key":34,"text":552,"correct":22},"净化空调系统的风管采用按扣式咬口连接","BC",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":568,"analysis":37},1136791,"数字视频监控（DVR）系统由（）组成。",[558,560,562,564,566],{"key":20,"text":559,"correct":26},"数字摄像机",{"key":24,"text":561,"correct":26},"硬盘录像机",{"key":28,"text":563,"correct":22},"矩阵控制器",{"key":31,"text":565,"correct":22},"传输控制线",{"key":34,"text":567,"correct":26},"图像记录","ABE",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":583,"analysis":37},1136793,"在给水系统调试检测中，需要检测的有（）。",[573,575,577,579,581],{"key":20,"text":574,"correct":26},"压力参数",{"key":24,"text":576,"correct":26},"水泵投运切换",{"key":28,"text":578,"correct":26},"故障报警",{"key":31,"text":580,"correct":22},"冷水温度",{"key":34,"text":582,"correct":26},"系统液位","ABCE",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":598,"analysis":37},1136794,"下列系统调试检测内容中，属于变配电系统调试检测的有（）。",[588,590,592,594,596],{"key":20,"text":589,"correct":26},"变压器超温报警",{"key":24,"text":591,"correct":22},"配电线路直流电阻",{"key":28,"text":593,"correct":26},"储油罐液位监视",{"key":31,"text":595,"correct":26},"应急发电机机组供电电流",{"key":34,"text":597,"correct":26},"不间断电源状态","ACDE",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":568,"analysis":37},1136795,"空调风管的风阀控制器安装前应检查线圈和阀体间的（）是否符合要求。",[603,605,607,609,611],{"key":20,"text":604,"correct":26},"电阻",{"key":24,"text":606,"correct":26},"供电电压",{"key":28,"text":608,"correct":22},"额定电流",{"key":31,"text":610,"correct":22},"输出信号",{"key":34,"text":612,"correct":26},"输入信号",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":52,"analysis":37},1136796,"综合布线系统由（）、设备间、进线间、管理七部分组成。",[617,619,621,623,625],{"key":20,"text":618,"correct":26},"工作区",{"key":24,"text":620,"correct":26},"配线子系统",{"key":28,"text":622,"correct":26},"干线子系统",{"key":31,"text":624,"correct":26},"建筑群子系统",{"key":34,"text":626,"correct":22},"安全防范系统",{"id":628,"libraryId":5,"type":15,"typeLabel":16,"stem":629,"options":630,"answer":553,"analysis":37},1136797,"空调工程承包商提供空调设备时，应同时提供满足监测和控制要求的（）。",[631,633,635,637,639],{"key":20,"text":632,"correct":22},"通信卡",{"key":24,"text":634,"correct":26},"通信协议",{"key":28,"text":636,"correct":26},"接口软件",{"key":31,"text":638,"correct":22},"型号规格",{"key":34,"text":640,"correct":22},"安装说明",{"id":642,"libraryId":5,"type":15,"typeLabel":16,"stem":643,"options":644,"answer":52,"analysis":37},1136798,"安全防范系统的子系统主要包括（）等。",[645,647,649,651,653],{"key":20,"text":646,"correct":26},"入侵报警系统",{"key":24,"text":648,"correct":26},"视频监控系统",{"key":28,"text":650,"correct":26},"出入口控制系统",{"key":31,"text":652,"correct":26},"电子巡查系统",{"key":34,"text":654,"correct":22},"联动控制系统",{"id":656,"libraryId":5,"type":15,"typeLabel":16,"stem":657,"options":658,"answer":583,"analysis":37},1136799,"下列检测参数,在公共广播系统检测时应重点关注的有（）。",[659,661,663,665,667],{"key":20,"text":660,"correct":26},"声场不均匀度",{"key":24,"text":662,"correct":26},"漏出声衰减",{"key":28,"text":664,"correct":26},"设备信噪比",{"key":31,"text":666,"correct":22},"报警信息的保存时间",{"key":34,"text":668,"correct":26},"语声响应时间",{"id":670,"libraryId":5,"type":15,"typeLabel":16,"stem":671,"options":672,"answer":52,"analysis":37},1136800,"建筑设备监控信号线缆的施工，其（）等应符合相关标准的规定。",[673,675,677,679,681],{"key":20,"text":674,"correct":26},"屏蔽性能",{"key":24,"text":676,"correct":26},"敷设方式",{"key":28,"text":678,"correct":26},"接头工艺",{"key":31,"text":680,"correct":26},"接地要求",{"key":34,"text":682,"correct":22},"电流密度",{"id":684,"libraryId":5,"type":15,"typeLabel":16,"stem":685,"options":686,"answer":210,"analysis":37},1136801,"空调设备的监控系统中，温度传感器至现场控制器之间的连接要求有（）。",[687,689,691,693,695],{"key":20,"text":688,"correct":26},"镍温度传感器的接线电阻应小于3Ω",{"key":24,"text":690,"correct":26},"铂温度传感器的接线电阻应小于1Ω",{"key":28,"text":692,"correct":26},"屏蔽线缆的接地应在现场控制器侧",{"key":31,"text":694,"correct":22},"温度传感器的连接线采用同轴电缆",{"key":34,"text":696,"correct":22},"屏蔽线缆的接地点应在金属管路侧",{"id":698,"libraryId":5,"type":15,"typeLabel":16,"stem":699,"options":700,"answer":583,"analysis":37},1136802,"公共广播系统应检测的内容包括（）。",[701,703,705,707,709],{"key":20,"text":702,"correct":26},"紧急广播具有最高优先权",{"key":24,"text":704,"correct":26},"扬声器位置",{"key":28,"text":706,"correct":26},"输出信噪比",{"key":31,"text":708,"correct":22},"功能",{"key":34,"text":710,"correct":26},"紧急广播相关响应时间",{"id":712,"libraryId":5,"type":15,"typeLabel":16,"stem":713,"options":714,"answer":151,"analysis":37},1136803,"空调设备的自动监控系统中常用的温度传感器有（）等类型。",[715,717,719,721,723],{"key":20,"text":716,"correct":22},"1kΩ铜电阻",{"key":24,"text":718,"correct":22},"1kΩ铝电阻",{"key":28,"text":720,"correct":26},"1kΩ镍电阻",{"key":31,"text":722,"correct":26},"1kΩ铂电阻",{"key":34,"text":724,"correct":22},"1kΩ银电阻",{"id":726,"libraryId":5,"type":15,"typeLabel":16,"stem":727,"options":728,"answer":312,"analysis":37},1136804,"下列设备中，属于安全防范系统的入侵报警探测器有（）。",[729,731,733,735,737],{"key":20,"text":730,"correct":26},"红外线探测器",{"key":24,"text":732,"correct":22},"感烟探测器",{"key":28,"text":734,"correct":26},"微波探测器",{"key":31,"text":736,"correct":26},"超声波探测器",{"key":34,"text":738,"correct":22},"感温探测器",[740,744,747,750,753,756],{"id":741,"name":742,"category":7,"favorite":743},1,"领导干部任职前廉政法规知识测试题",92,{"id":745,"name":746,"category":7,"favorite":741},595,"建筑结构与设备",{"id":748,"name":749,"category":7,"favorite":741},715,"招标采购专业知识与法律法规",{"id":751,"name":752,"category":7,"favorite":741},848,"市政方向-通用基础",{"id":754,"name":755,"category":7,"favorite":8},534,"BIM工程师",{"id":757,"name":755,"category":7,"favorite":8},535]