[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1137356":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1137356,797,2,"多选题","（2019年真题）下列有关于不锈钢工艺管道水冲洗实施要点，正确的是（ ）",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","水中氯离子含量不得超过 25ppm",true,{"key":16,"text":17,"correct":14},"B","水冲洗流速不得低于 1.5m\u002Fs",{"key":19,"text":20,"correct":14},"C","排放管在排水时不得形成负压",{"key":22,"text":23,"correct":24},"D","排放管径小于被冲洗管径的 60％",false,{"key":26,"text":27,"correct":24},"E","冲洗压力应大于管道的设计压力","ABC","水冲洗实施要点： （1）水冲洗应使用洁净水。冲洗不锈钢管、镍及镍合金钢管道，水中氯离子含量不得超过 25ppm（25×10-6）。 （2）水冲洗流速不得低于 1.5m\u002Fs，冲洗压力不得超过管道的设计压力。 （3）水冲洗排放管的截面积不应小于被冲洗管截面积的 60％，排水时不得形成负压。 （4）水冲洗应连续进行，当设计无规定时，以排出口的水色和透明度与入口水目测一致为合格。管道水 冲洗合格后，应及时将管内积水排净，并应及时吹干。",{"id":6,"name":31,"category":32,"favorite":33},"一建机电工程实务","建筑工程",0]