[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1137342":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1137342,797,2,"多选题","（2012年真题）胀锚地脚螺栓安装时，符合施工要求的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","螺栓中心距基础边缘的距离不小于 5 倍的胀锚螺栓直径",false,{"key":16,"text":17,"correct":14},"B","安装胀锚螺栓的基础强度不得大于 10MPa",{"key":19,"text":20,"correct":21},"C","钻孔处不得有裂缝",true,{"key":23,"text":24,"correct":21},"D","钻孔的钻头不应与基础中的钢筋相碰",{"key":26,"text":27,"correct":21},"E","钻孔直径和深度应与胀锚地脚螺栓相匹配","CDE","本题考察的设备固定方式。部分静置的简单设备或辅助设备有时采用胀锚地脚螺栓的连接方式。 胀锚地脚螺栓安装应满足下列要求： （1）胀锚地脚螺栓中心到基础边缘的距离不小于 7 倍的胀锚地脚螺栓直径； （2）安装胀锚地脚螺栓的基础强度不得小于 10MPa； （3）钻孔处不得有裂缝，钻孔时应防止钻头与基础中的钢筋、埋管等相碰； （4）钻孔直径和深度应与胀锚地脚螺栓相匹配。",{"id":6,"name":31,"category":32,"favorite":33},"一建机电工程实务","建筑工程",0]