[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1137238":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1137238,797,2,"多选题","工业管道泄漏性试验实施要点包括（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","输送极度危害介质的管道应必须进行泄漏性试验",true,{"key":16,"text":17,"correct":14},"B","泄漏性试验在压力试验合格后进行",{"key":19,"text":20,"correct":14},"C","泄漏性试验压力为设计压力",{"key":22,"text":23,"correct":24},"D","泄漏性试验的试验介质为输送介质",false,{"key":26,"text":27,"correct":24},"E","检查部位包括焊缝","ABC","管道泄漏性试验实施要点： （1）输送极度和高度危害介质以及可燃介质的管道，必须进行泄漏性试验。 （2）应在压力试验合格后进行，试验介质宜采用空气。 （3）试验压力为设计压力。 （4）泄漏性试验可结合试车一并进行。 （5）泄漏性试验应逐级缓慢升压，当达到试验压力，并且停压10min后，采用涂刷中性发泡剂等方法巡回检查阀门填料函、法兰或者螺纹连接处、放空阀、排气阀、排水阀等所有密封点无泄漏为合格。",{"id":6,"name":31,"category":32,"favorite":33},"一建机电工程实务","建筑工程",0]