[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1136971":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1136971,797,2,"多选题","下列关于粘贴法施工要求的说法，正确的有（）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","粘贴剂在使用前应进行实地试粘",true,{"key":16,"text":17,"correct":14},"B","绝热制品临时固定用的卡具和橡胶带，应在粘贴剂干固后拆除",{"key":19,"text":20,"correct":21},"C","保冷制品的缺棱掉角部分应在制品粘贴时填补",false,{"key":23,"text":24,"correct":14},"D","球形容器保冷层宜采用预制成型的弧形板粘贴",{"key":26,"text":27,"correct":21},"E","采用泡沫玻璃制品粘贴时，不得在制品的断面涂抹粘贴剂","ABD","2020版教材P157 \u002F 2019版教材P145 7.粘贴法施工要求。（1）粘结剂在使用前，应进行实地试粘。施工中粘结剂取用后应及时密封。粘结剂的涂抹厚度应符合要求，并应涂满、挤紧和粘牢。（2）粘贴操作时，连续粘贴的层高，应根据粘结剂固化时间确定。绝热制品可随粘随用卡具或橡胶带临时固定，应待粘结剂干固后拆除。（3）粘贴在管道上的绝热制品的内径，应略大于管道外径。保冷制品的缺棱掉角部分，应事先修补完整后粘贴。保温制品可在粘贴时填补。（4）球形容器的保冷层宜采用预制成型的弧形板，粘贴前粘结剂应点状涂抹在预制板上，并应与壁面贴紧。（5）当采用泡沫玻璃制品进行粘贴施工时，尚应在制品端、侧、结合面涂粘结剂相互粘合。（6）大型异型设备和管道的绝热层，采用半硬质、软质绝热制品粘贴时，应采用层铺法施工，各层绝热制品应逐层错缝、压缝粘贴。",{"id":6,"name":31,"category":32,"favorite":33},"一建机电工程实务","建筑工程",0]