[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1136931":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1136931,797,2,"多选题","关于自动化工程的控制阀和执行机构试验的说法，正确的有（）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","阀体压力试验可以对制造厂出具的产品合格证明进行验证",true,{"key":16,"text":17,"correct":14},"B","事故切断阀应进行阀座的密封试验",{"key":19,"text":20,"correct":14},"C","进行缸体泄漏性试验以及行程试验",{"key":22,"text":23,"correct":14},"D","事故切断阀应进行全行程时间试验",{"key":25,"text":26,"correct":27},"E","执行机构在试验时调整到最大状态",false,"ABCD","2020版教材P143 \u002F 2019版教材P133 7.控制阀和执行机构的试验应符合下列要求：（1）阀体压力试验和阀座密封试验等项目，可对制造厂出具的产品合格证明和试验报告进行验证，对事故切断阀应进行阀座密封试验。（2）应进行膜头、缸体泄漏性试验以及行程试验。（3）事故切断阀和设计规定了全行程时间的阀门，应进行全行程时间试验。（4）执行机构在试验时应调整到设计文件规定的工作状态。",{"id":6,"name":31,"category":32,"favorite":33},"一建机电工程实务","建筑工程",0]