[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1136816":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1136816,797,2,"多选题","自动扶梯、自动人行道必须自动停止运行，在（）情况下，开关断开的动作必须通过安全电路来完成。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","无控制电压",false,{"key":16,"text":17,"correct":14},"B","电路接地的故障",{"key":19,"text":20,"correct":14},"C","过载",{"key":22,"text":23,"correct":24},"D","控制装置在超速和运行方向非操纵逆转下动作",true,{"key":26,"text":27,"correct":24},"E","直接驱动梯级、踏板或胶带的部件（如链条或齿条）断裂或过分伸长","DE","2020版教材P224 \u002F 2019版教材P212 整机安装验收要求 ( 1 )自动扶梯、自动人行道必须自动停止运行的情况有: 1 )元控制电压、电路接地的故障、过载。 2) 控制装置在超速和运行方向非操纵逆转下动作;附加制动器动作。 3 )直接驱动梯级、踏板或胶带的部件断裂或过分伸长;驱动装置与转向装置之间的距离缩短。 4 )梯级、踏板或胶带进入梳齿板处有异物夹住，且产生损坏梯级、踏板或胶带支撑结构;梯级或踏板下陷。 5 )元中间出口的连续安装的多台自动扶梯、自动人行道中的一台停止运行。 6) 扶手带人口保护装置动作。",{"id":6,"name":31,"category":32,"favorite":33},"一建机电工程实务","建筑工程",0]