[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1136787":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1136787,797,2,"多选题","关于多联机组的制冷剂管道及管件安装要求，正确的有（）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","制冷剂管道弯管的弯曲半径不应小于2.5倍管道直径",false,{"key":16,"text":17,"correct":18},"B","最大外径与最小外径之差不应大于0.08倍管道直径，且不应使用焊接弯管及皱褶弯管",true,{"key":20,"text":21,"correct":18},"C","制冷剂管道的分支管应按介质流向弯成90°与主管连接",{"key":23,"text":24,"correct":14},"D","采用对接焊接的铜管管道错边量不应大于0.2倍壁厚",{"key":26,"text":27,"correct":18},"E","采用承插钎焊连接的铜管承口应迎着介质流动方向","BCE","2020版教材P201 \u002F 2019版教材P189 2.制冷剂管道、管件安装要求。（1）制冷剂管道弯管的弯曲半径不应小于3.5倍管道直径，最大外径与最小外径之差不应大于0.08倍管道直径，且不应使用焊接弯管及皱褶弯管。（2）制冷剂管道的分支管，应按介质流向弯成90。与主管连接，不宜使用弯曲半径小于1.5倍管道直径的压制弯管。（3）铜管切口应平整，不得有毛刺、凹凸等缺陷，切口允许倾斜偏差应为管径的1%;管扩口应保持同心，不得有开裂及皱褶，并应有良好的密封面。（4）铜管采用承插钎焊焊接连接时，承口应迎着介质流动方向。当采用套管钎焊焊接连接时，插接深度应符合规定；当采用对接焊接时，管道内壁应齐平，错边量不应大于0.1倍壁厚，且不大于1mm。所以答案B.C.E正确。",{"id":6,"name":31,"category":32,"favorite":33},"一建机电工程实务","建筑工程",0]