[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1136533":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1136533,797,1,"单选题","（2014年真题）关于建筑管道系统试验的说法，正确的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","采用气压试验时，应编制专项方案，并经监理批准",false,{"key":16,"text":17,"correct":14},"B","室外排水管网应按系统进行整体试验",{"key":19,"text":20,"correct":21},"C","首层两处室内消火栓试射，检验两股充实水柱同时喷射到达最远点的能力",true,{"key":23,"text":24,"correct":14},"D","当设计未注明试验压力时，应按类似工程经验数据进行压力试验","本题考查的是建筑管道系统。选项 A 应为“压力试验宜采用液压试验并应编制专项方案，当需要 进行气压试验时应有设计人员的批准”；选项 B 应为“室外排水管网按排水检查井分段试验”；选项 D 应 为“按规范要求进行”。",{"id":6,"name":27,"category":28,"favorite":29},"一建机电工程实务","建筑工程",0]