[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1135758":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},1135758,797,1,"单选题","阀门的壳体试验压力为阀门在20℃时最大允许工作压力的（）倍。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","1.10",false,{"key":16,"text":17,"correct":14},"B","1.15",{"key":19,"text":20,"correct":14},"C","1.25",{"key":22,"text":23,"correct":24},"D","1.50",true,"2020版教材P94 \u002F 2019版教材P83 （2）阀门应进行壳体压力试验和密封试验： 1）阀门壳体试验压力和密封试验应以洁净水为介质，不锈钢阀门试验时，水中的氯离子含量不得超过25ppm。 2）阀门的壳体试验压力为阀门在20℃时最大允许工作压力的1.5倍，密封试验为阀门在20℃时最大允许工作压力的1.1倍，试验持续时间不得少于5min，无特殊规定时，试验温度为5~40℃，低于5℃时，应采取升温措施。 3）安全阀的校验应按照国家现行标准《安全阀安全技术监察规程》和设计文件的规定进行整定压力调整和密封试验，委托有资质的检验机构完成，安全阀校验应做好记录、铅封，并出具校验报告。",{"id":6,"name":27,"category":28,"favorite":29},"一建机电工程实务","建筑工程",0]