[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1135182":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1135182,796,2,"多选题","导致钻孔灌注桩施工中断桩的原因有（ ），",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","混凝土坍落度太小，骨料太大，运输距离过长，混凝土和易性差",true,{"key":16,"text":17,"correct":14},"B","计算导管埋管深度时出错，或盲目提升导管，使导管脱离混凝土面",{"key":19,"text":20,"correct":14},"C","钢筋笼将导管卡住，强力拔管时，使泥浆混入混凝土中",{"key":22,"text":23,"correct":24},"D","桩底清孔不彻底",false,{"key":26,"text":27,"correct":14},"E","导管接头处渗漏，泥浆进入管内，混入混凝土中","ABCE","2020版教材P159\u002F2019版教材P150 （1）混凝土坍落度太小，骨料太大，运输距离过长，混凝土和易性差，致使导管堵塞，疏通堵管再浇筑混凝土时，中间就会形成夹泥层。（2）计算导管埋管深度时出错，或盲目提升导管，使导管脱离混凝土面，再浇筑混凝土时，中间就会形成夹泥层。（3）钢筋笼将导管卡住，强力拔管时，使泥浆混入混凝土中。（4）导管接头处渗漏，泥浆进入管内，混人混凝土中。（5）混凝土供应中断，不能连续浇筑，中断时间过长，造成堵管事故。",{"id":6,"name":31,"category":32,"favorite":33},"一建公路工程实务","建筑工程",0]