[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-792-52":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":722},{"id":5,"name":6,"category":7,"favorite":8},792,"二建市政工程实务","建筑工程",0,52,50,2846,[13,38,53,68,83,98,113,128,139,153,166,181,195,209,223,238,253,268,283,298,312,326,338,352,367,381,395,406,421,436,450,464,478,491,505,519,533,547,561,575,588,603,617,629,643,657,670,680,694,709],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1127161,2,"多选题","确定夯管锤的锤击力主要根据( )。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","管径",true,{"key":24,"text":25,"correct":22},"B","钢管力学性能",{"key":27,"text":28,"correct":29},"C","夯管锤重量",false,{"key":31,"text":32,"correct":22},"D","管道长度",{"key":34,"text":35,"correct":22},"E","工程地质、水文地质和周围环境条件","ABDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1127162,"关于给水排水工程中砌筑结构对材料的基本要求，正确的有( )。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"机制烧结砖应边角整齐、表面平整、尺寸准确，强度不低于MU10",{"key":24,"text":45,"correct":22},"石料应质地坚实均匀，无风化剥落层和裂纹",{"key":27,"text":47,"correct":22},"混凝土砌块应符合设计要求和相关标准规定",{"key":31,"text":49,"correct":29},"砌筑砂浆应采用水泥砂浆，其强度等级应符合设计要求，且不应低于M15",{"key":34,"text":51,"correct":22},"水泥应符合《砌体结构工程施工质量验收规范》GB50203-2011的规定","ABCE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1127163,"砌筑沟槽施工的规定有( )。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"砌体应上下错缝、内外搭砌",{"key":24,"text":60,"correct":29},"砌筑施工需间断时，应预留直槎",{"key":27,"text":62,"correct":22},"当砌体垂直灰缝宽度大于30㎜时，应采用细石混凝土灌实",{"key":31,"text":64,"correct":29},"砌筑前砌块（砖、石）应充分干透",{"key":34,"text":66,"correct":22},"转角处和交接处应与墙体同时砌筑","ACE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1127164,"下列管道功能性试验的规定，正确的是( )。",[72,74,76,78,80],{"key":20,"text":73,"correct":29},"压力管道应进行水压试验，包括强度试验和严密性试验",{"key":24,"text":75,"correct":29},"无压管道的严密性试验只能采用闭水试验而不能采用闭气试验",{"key":27,"text":77,"correct":29},"管道严密性试验，宜采用注水法进行",{"key":31,"text":79,"correct":22},"注水应从下游缓慢注入，在试验管段上游的管顶及管段中的高点应设置排气阀",{"key":34,"text":81,"correct":22},"当管道采用两种（或多种）管材时，宜按不同管材分别进行试验","DE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},1127165,"关于给水排水工程砌筑结构中的砂浆抹面的基本要求，正确的有( )。",[87,89,91,93,95],{"key":20,"text":88,"correct":22},"墙壁表面粘结的杂物应清理干净，并洒水湿润",{"key":24,"text":90,"correct":22},"抹面宜分两道，第一道应抹平且表面粗糙，第二道抹平后，应分两次压实抹光",{"key":27,"text":92,"correct":22},"施工缝留成阶梯形，接槎时先均匀涂刷水泥浆一道，并依次抹压，使接茬严密",{"key":31,"text":94,"correct":22},"阴阳角应抹成圆角",{"key":34,"text":96,"correct":29},"抹面砂浆终凝后，湿润养护时间不宜少于7d","ABCD",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":112,"analysis":37},1127166,"关于给水排水压力管道水压试验的准备工作，正确的有( )。",[102,104,106,108,110],{"key":20,"text":103,"correct":29},"管道未回填土且沟槽内无积水",{"key":24,"text":105,"correct":22},"应做好水源引接、排水等疏导方案",{"key":27,"text":107,"correct":22},"试验前应清除管道内的杂物",{"key":31,"text":109,"correct":22},"试验管段所有敞口应封闭，不得有渗漏水现象",{"key":34,"text":111,"correct":22},"试验管段不得用闸阀做堵板，不得含有消火栓、水锤消除器、安全阀等附件","BCDE",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":127,"analysis":37},1127167,"必须经严密性试验合格后方可投入运行的管道有( )。",[117,119,121,123,125],{"key":20,"text":118,"correct":22},"污水管道",{"key":24,"text":120,"correct":22},"雨污水合流管道",{"key":27,"text":122,"correct":29},"设计无要求时，单口水压试验合格的玻璃钢无压管道",{"key":31,"text":124,"correct":29},"设计无要求时，单口水压试验合格的预应力混凝土无压管道",{"key":34,"text":126,"correct":22},"湿陷土、膨胀土、流砂地区的雨水管道","ABE",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":97,"analysis":37},1127168,"压力管道试验准备工作包括( )。",[132,133,134,136,137],{"key":20,"text":109,"correct":22},{"key":24,"text":111,"correct":22},{"key":27,"text":135,"correct":22},"水压试验前应清除管道内的杂物",{"key":31,"text":105,"correct":22},{"key":34,"text":138,"correct":29},"管道已回填土",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":52,"analysis":37},1127169,"地下管道局部修补时采用的方法主要有铰接管法、灌浆法和( )。",[143,145,147,149,151],{"key":20,"text":144,"correct":22},"机器人法",{"key":24,"text":146,"correct":22},"密封法",{"key":27,"text":148,"correct":22},"补丁法",{"key":31,"text":150,"correct":29},"胀管法",{"key":34,"text":152,"correct":22},"局部软衬法",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":97,"analysis":37},1127170,"( )管道，必须经严密性试验合格后方可投入运行。",[157,159,160,162,164],{"key":20,"text":158,"correct":22},"污水",{"key":24,"text":120,"correct":22},{"key":27,"text":161,"correct":22},"流砂地区雨水管道",{"key":31,"text":163,"correct":22},"膨胀土地区雨水管道",{"key":34,"text":165,"correct":29},"黏土地区雨水管道",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":180,"analysis":37},1127171,"污水管道闭水试验应符合的要求有( )。",[170,172,174,176,178],{"key":20,"text":171,"correct":22},"在管道填土前进行",{"key":24,"text":173,"correct":22},"在管道灌满水24h后进行",{"key":27,"text":175,"correct":29},"在抹带完成前进行",{"key":31,"text":177,"correct":22},"渗水量的测定时间不小于30min",{"key":34,"text":179,"correct":29},"试验水位应为下游管道内顶以上2m","ABD",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":97,"analysis":37},1127172,"城市管道巡视检查内容包括( )。",[185,187,189,191,193],{"key":20,"text":186,"correct":22},"管道漏点监测",{"key":24,"text":188,"correct":22},"地下管线定位监测",{"key":27,"text":190,"correct":22},"管道变形检查",{"key":31,"text":192,"correct":22},"管道附属设施检查",{"key":34,"text":194,"correct":29},"管网规划调查",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":97,"analysis":37},1127173,"城市管道巡视检查，检测手段包括( )等方法及仪器设备。",[199,201,203,205,207],{"key":20,"text":200,"correct":22},"探测雷达",{"key":24,"text":202,"correct":22},"声呐",{"key":27,"text":204,"correct":22},"红外线检查",{"key":31,"text":206,"correct":22},"闭路监视系统",{"key":34,"text":208,"correct":29},"水准仪",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":67,"analysis":37},1127174,"采用爆管法进行旧管更新，按照爆管工具的不同，可将爆管分为( )。",[213,215,217,219,221],{"key":20,"text":214,"correct":22},"气动爆管",{"key":24,"text":216,"correct":29},"水压爆管",{"key":27,"text":218,"correct":22},"液动爆管",{"key":31,"text":220,"correct":29},"静力破碎爆管",{"key":34,"text":222,"correct":22},"切割爆管",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":237,"analysis":37},1127175,"不是按热媒分类的热力管网有( )。",[227,229,231,233,235],{"key":20,"text":228,"correct":29},"蒸汽热网",{"key":24,"text":230,"correct":22},"一级管网",{"key":27,"text":232,"correct":22},"开式系统",{"key":31,"text":234,"correct":29},"热水热网",{"key":34,"text":236,"correct":22},"直埋敷设管网","BCE",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":252,"analysis":37},1127176,"城市热力管网中，蒸汽热网可分为( )。",[242,244,246,248,250],{"key":20,"text":243,"correct":29},"超高压蒸汽热网",{"key":24,"text":245,"correct":22},"高压蒸汽热网",{"key":27,"text":247,"correct":22},"中压蒸汽热网",{"key":31,"text":249,"correct":22},"低压蒸汽热网",{"key":34,"text":251,"correct":29},"超低压蒸汽热网","BCD",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":267,"analysis":37},1127177,"供热蒸汽热网按其压力一般可分为( )蒸汽热网。",[257,259,261,263,265],{"key":20,"text":258,"correct":22},"高压",{"key":24,"text":260,"correct":22},"低压",{"key":27,"text":262,"correct":22},"中压",{"key":31,"text":264,"correct":29},"超高压",{"key":34,"text":266,"correct":29},"一般","ABC",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":282,"analysis":37},1127178,"按供回对热网分类时，蒸汽热网的管道组成为( )。",[272,274,276,278,280],{"key":20,"text":273,"correct":22},"供汽管",{"key":24,"text":275,"correct":29},"回水管",{"key":27,"text":277,"correct":22},"凝水管",{"key":31,"text":279,"correct":29},"供水管",{"key":34,"text":281,"correct":29},"热水管","AC",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":297,"analysis":37},1127180,"一次热网与二次热网用换热器相连，一次热网热媒损失小，但中间设备多，实际使用较广泛的不是以下( )系统。",[287,289,291,293,295],{"key":20,"text":288,"correct":22},"开式",{"key":24,"text":290,"correct":29},"闭式",{"key":27,"text":292,"correct":22},"供水",{"key":31,"text":294,"correct":22},"回水",{"key":34,"text":296,"correct":22},"冷却","ACDE",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":267,"analysis":37},1127181,"架空敷设的支架按其支撑结构高度不同一般可分为( )。",[302,304,306,308,310],{"key":20,"text":303,"correct":22},"高支架",{"key":24,"text":305,"correct":22},"中支架",{"key":27,"text":307,"correct":22},"低支架",{"key":31,"text":309,"correct":29},"地支架",{"key":34,"text":311,"correct":29},"导向支架",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":252,"analysis":37},1127182,"敷设热力管网的方式一般可分为( )。",[316,318,320,322,324],{"key":20,"text":317,"correct":29},"供回水敷设",{"key":24,"text":319,"correct":22},"管沟敷设",{"key":27,"text":321,"correct":22},"架空敷设",{"key":31,"text":323,"correct":22},"直埋敷设",{"key":34,"text":325,"correct":29},"低支架敷设",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":237,"analysis":37},1127183,"下列敷设方式中属于管沟敷设的是( )。",[330,331,333,335,336],{"key":20,"text":303,"correct":29},{"key":24,"text":332,"correct":22},"通行管沟",{"key":27,"text":334,"correct":22},"不通行管沟",{"key":31,"text":307,"correct":29},{"key":34,"text":337,"correct":22},"半通行管沟",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":36,"analysis":37},1127184,"城市热力管道在实施焊接前，应根据焊接工艺试验结果编写焊接工艺方案，包括以下主要内容：管材、板材性能和焊接材料；焊接方法；焊接电流的选择；( )。",[342,344,346,348,350],{"key":20,"text":343,"correct":22},"焊接结构形式及外形尺寸",{"key":24,"text":345,"correct":22},"焊接接头的组对要求及允许偏差",{"key":27,"text":347,"correct":29},"焊缝长度及点数的规定",{"key":31,"text":349,"correct":22},"坡口形式及制作方法",{"key":34,"text":351,"correct":22},"检验方法及合格标准",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":366,"analysis":37},1127185,"管网工程竣工后，应进行符合当地有关部门要求的全部( )测量。",[356,358,360,362,364],{"key":20,"text":357,"correct":22},"平面位置",{"key":24,"text":359,"correct":22},"高程",{"key":27,"text":361,"correct":29},"坐标",{"key":31,"text":363,"correct":29},"高度",{"key":34,"text":365,"correct":29},"地图","AB",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":52,"analysis":37},1127186,"热力管道穿过构筑物墙板处应按设计要求安装套管，套管的安装要求是( )。",[371,373,375,377,379],{"key":20,"text":372,"correct":22},"穿过结构的套管长度每侧应大于墙厚20㎜",{"key":24,"text":374,"correct":22},"穿过楼板的套管应高出板面50㎜",{"key":27,"text":376,"correct":22},"套管与管道之间的空隙可采用柔性材料堵塞",{"key":31,"text":378,"correct":29},"防水套管应按设计要求制作，并应在墙体和构筑物砌筑或浇筑混凝土之后安装就位",{"key":34,"text":380,"correct":22},"套管中心的允许偏差为0～10㎜",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":394,"analysis":37},1127187,"吊架可分为( )等形式。",[385,386,388,390,392],{"key":20,"text":311,"correct":29},{"key":24,"text":387,"correct":22},"刚性吊架",{"key":27,"text":389,"correct":22},"弹簧吊架",{"key":31,"text":391,"correct":29},"滚动支架",{"key":34,"text":393,"correct":29},"滑动支架","BC",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":52,"analysis":37},1127188,"供热管件附件及安装中，支架可分为（）等形式。",[399,401,402,404,405],{"key":20,"text":400,"correct":22},"弹簧支架",{"key":24,"text":311,"correct":22},{"key":27,"text":403,"correct":22},"固定支架",{"key":31,"text":391,"correct":29},{"key":34,"text":393,"correct":22},{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":420,"analysis":37},1127189,"下列选项中，属于城市热力管网主要附件的有( )。",[410,412,414,416,418],{"key":20,"text":411,"correct":22},"支吊架",{"key":24,"text":413,"correct":29},"阀门井",{"key":27,"text":415,"correct":22},"补偿器",{"key":31,"text":417,"correct":22},"阀门",{"key":34,"text":419,"correct":29},"放散管","ACD",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":435,"analysis":37},1127190,"利用自身的可伸缩性吸收管道热伸长的补偿器有（）。",[425,427,429,431,433],{"key":20,"text":426,"correct":29},"自然补偿器",{"key":24,"text":428,"correct":29},"方形补偿器",{"key":27,"text":430,"correct":22},"波纹管补偿器",{"key":31,"text":432,"correct":29},"球形补偿器",{"key":34,"text":434,"correct":22},"套筒补偿器","CE",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":67,"analysis":37},1127191,"换热站是供热管网的重要附属设施，是与热用户的连接场所。它的作用是( )。",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"调节、转换热网输送的热媒",{"key":24,"text":443,"correct":29},"集中供热管道中的凝结水",{"key":27,"text":445,"correct":22},"计量、检测供热热媒的参数和数量",{"key":31,"text":447,"correct":29},"保证供热温度",{"key":34,"text":449,"correct":22},"向热用户系统分配热量",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":366,"analysis":37},1127192,"热力管道工程施工结束后，应进行( )及试运行。",[454,456,458,460,462],{"key":20,"text":455,"correct":22},"清洗",{"key":24,"text":457,"correct":22},"试验",{"key":27,"text":459,"correct":29},"吹扫管道",{"key":31,"text":461,"correct":29},"保温",{"key":34,"text":463,"correct":29},"刷漆",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":36,"analysis":37},1127193,"关于清（吹）洗的规定表述正确的有（）。",[468,470,472,474,476],{"key":20,"text":469,"correct":22},"清洗前，应将系统内的流量孔板、滤网和止回阀阀芯拆除",{"key":24,"text":471,"correct":22},"清洗前，要根据情况对固定支架、弯头等部位进行必要的加固",{"key":27,"text":473,"correct":29},"供热的供水和回水管道必须用蒸汽清洗",{"key":31,"text":475,"correct":22},"供热管网的清洗应在试运行前进行",{"key":34,"text":477,"correct":22},"清洗方法应根据供热管道的运行要求、介质类别而定",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":52,"analysis":37},1127194,"关于供热管网清（吹）洗规定的说法，正确的有( )。",[482,483,485,487,489],{"key":20,"text":475,"correct":22},{"key":24,"text":484,"correct":22},"清洗前，应编制清洗方案",{"key":27,"text":486,"correct":22},"清洗应按主干线、支干线、支线分别进行",{"key":31,"text":488,"correct":29},"二级管网可与一级管网一起清洗",{"key":34,"text":490,"correct":22},"蒸汽管道应用蒸汽吹洗",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":297,"analysis":37},1127195,"关于供热管网试运行的要求，正确的有( )。",[495,497,499,501,503],{"key":20,"text":496,"correct":22},"供热管线工程宜与换热站工程联合进行试运行",{"key":24,"text":498,"correct":29},"试运行开始后，每隔1h对补偿器及其他管路附件进行检查，并做好记录",{"key":27,"text":500,"correct":22},"试运行期间，管道法兰、阀门、补偿器及仪表等处的螺栓应进行热拧紧",{"key":31,"text":502,"correct":22},"试运行期间发现的问题，不影响试运行安全的，可待试运行结束后处理",{"key":34,"text":504,"correct":22},"试运行期间出现需要立即解决的问题，当即停止试运行，进行处理",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":36,"analysis":37},1127196,"关于供热管道用蒸汽吹洗的要求，正确的有( )。",[509,511,513,515,517],{"key":20,"text":510,"correct":22},"蒸汽吹洗的排气管应引出室外，管口不得朝下并应设临时固定支架",{"key":24,"text":512,"correct":22},"蒸汽吹洗前应先暖管，恒温1h达到设计要求后进行吹洗",{"key":27,"text":514,"correct":29},"吹洗压力不应大于管道工作压力的80%",{"key":31,"text":516,"correct":22},"吹洗次数应为2～3次，每次的间隔时间宜为20～30min",{"key":34,"text":518,"correct":22},"吹洗后，要及时在管座、管端等部位掏除污物",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":127,"analysis":37},1127197,"工业企业燃气管道包括( )。",[523,525,527,529,531],{"key":20,"text":524,"correct":22},"工厂引入管",{"key":24,"text":526,"correct":22},"厂区燃气管道",{"key":27,"text":528,"correct":29},"室内燃气管道",{"key":31,"text":530,"correct":29},"分配管道",{"key":34,"text":532,"correct":22},"车间燃气管道",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":67,"analysis":37},1127198,"燃气管道根据用途分类可分为( )。",[537,539,541,543,545],{"key":20,"text":538,"correct":22},"工业企业燃气管道",{"key":24,"text":540,"correct":29},"地下燃气管道",{"key":27,"text":542,"correct":22},"城市燃气管道",{"key":31,"text":544,"correct":29},"架牢燃气管道",{"key":34,"text":546,"correct":22},"长距离输气管道",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":52,"analysis":37},1127199,"城镇燃气，按燃气类别及其特性指标华白数分类，主要有( )。",[551,553,555,557,559],{"key":20,"text":552,"correct":22},"人工煤气",{"key":24,"text":554,"correct":22},"天然气",{"key":27,"text":556,"correct":22},"液化石油气混空气",{"key":31,"text":558,"correct":29},"二氧化碳",{"key":34,"text":560,"correct":22},"沼气",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":112,"analysis":37},1127200,"下面关于城市燃气管网系统的叙述中正确的是( )。",[565,567,569,571,573],{"key":20,"text":566,"correct":29},"一般由城市中压或次高压燃气管道构成大城市输配管网系统的外环网",{"key":24,"text":568,"correct":22},"有充要理由又安全措施可靠，经有关部门批准，特定区域可以采用次高压燃气管道",{"key":27,"text":570,"correct":22},"城市、工厂区和居民点可由长距离输气管线供气",{"key":31,"text":572,"correct":22},"个别距离城市燃气管道较远的大型用户，经论证确系经济合理和安全可靠时，可自设调压站与长输管线连接",{"key":34,"text":574,"correct":22},"单个居民用户不得与长输管线连接",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":587,"analysis":37},1127201,"大城市输配管网系统的外环网一般由城市( )燃气管道构成。",[579,581,583,584,586],{"key":20,"text":580,"correct":29},"中压A",{"key":24,"text":582,"correct":29},"中压B",{"key":27,"text":258,"correct":22},{"key":31,"text":585,"correct":22},"次高压",{"key":34,"text":260,"correct":29},"CD",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":602,"analysis":37},1127202,"高压燃气必须通过调压站才能送入( )。",[592,594,596,598,600],{"key":20,"text":593,"correct":22},"中压管道",{"key":24,"text":595,"correct":29},"储气罐",{"key":27,"text":597,"correct":29},"低压管道",{"key":31,"text":599,"correct":22},"高压储气罐",{"key":34,"text":601,"correct":22},"次高压管道","ADE",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":237,"analysis":37},1127203,"燃气管道根据输气压力分类，当管道内燃气压力不同时，对( )要求也不同。",[607,609,611,613,615],{"key":20,"text":608,"correct":29},"管道防腐",{"key":24,"text":610,"correct":22},"管道材质",{"key":27,"text":612,"correct":22},"安装质量",{"key":31,"text":614,"correct":29},"焊接质量",{"key":34,"text":616,"correct":22},"检验标准",{"id":618,"libraryId":5,"type":15,"typeLabel":16,"stem":619,"options":620,"answer":112,"analysis":37},1127204,"当管道内燃气输送压力不同时，对管道的( )要求也不同。",[621,623,625,626,627],{"key":20,"text":622,"correct":29},"试验方法",{"key":24,"text":624,"correct":22},"材质",{"key":27,"text":612,"correct":22},{"key":31,"text":616,"correct":22},{"key":34,"text":628,"correct":22},"运行管理",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":252,"analysis":37},1127205,"地下燃气管道不得在( )下面穿越。",[633,635,637,639,641],{"key":20,"text":634,"correct":29},"电车轨道",{"key":24,"text":636,"correct":22},"大型建筑物",{"key":27,"text":638,"correct":22},"小型建筑物",{"key":31,"text":640,"correct":22},"大型构筑物",{"key":34,"text":642,"correct":29},"热力管沟",{"id":644,"libraryId":5,"type":15,"typeLabel":16,"stem":645,"options":646,"answer":602,"analysis":37},1127206,"地下燃气管道不得穿越( )。",[647,649,651,653,655],{"key":20,"text":648,"correct":22},"热电厂",{"key":24,"text":650,"correct":29},"雨水口",{"key":27,"text":652,"correct":29},"街心花园",{"key":31,"text":654,"correct":22},"汽车加油站",{"key":34,"text":656,"correct":22},"化工原料仓库",{"id":658,"libraryId":5,"type":15,"typeLabel":16,"stem":659,"options":660,"answer":297,"analysis":37},1127207,"当燃气管道穿越( )时，宜将燃气管道敷设在套管内。",[661,663,665,667,668],{"key":20,"text":662,"correct":22},"铁路",{"key":24,"text":664,"correct":29},"河底",{"key":27,"text":666,"correct":22},"高速公路",{"key":31,"text":634,"correct":22},{"key":34,"text":669,"correct":22},"城镇主干道",{"id":671,"libraryId":5,"type":15,"typeLabel":16,"stem":672,"options":673,"answer":180,"analysis":37},1127209,"燃气管道穿越( )下面时，其外应加套管。",[674,675,676,678,679],{"key":20,"text":666,"correct":22},{"key":24,"text":662,"correct":22},{"key":27,"text":677,"correct":29},"建筑物",{"key":31,"text":669,"correct":22},{"key":34,"text":640,"correct":29},{"id":681,"libraryId":5,"type":15,"typeLabel":16,"stem":682,"options":683,"answer":127,"analysis":37},1127210,"关于燃气管道利用道路桥梁跨越河流的要求，正确的有( )。",[684,686,688,690,692],{"key":20,"text":685,"correct":22},"燃气管道的输送压力不应大于0.4MPa",{"key":24,"text":687,"correct":22},"管道应设置必要的补偿和减震措施",{"key":27,"text":689,"correct":29},"燃气管道随桥梁敷设时不能有同时敷设的其他管道",{"key":31,"text":691,"correct":29},"敷设于桥梁上的燃气管道的管材可不做特殊要求",{"key":34,"text":693,"correct":22},"对管道应做较高等级的防腐保护",{"id":695,"libraryId":5,"type":15,"typeLabel":16,"stem":696,"options":697,"answer":708,"analysis":37},1127211,"燃气管道穿越河底时，应符合( )等要求。",[698,700,702,704,706],{"key":20,"text":699,"correct":29},"稳管措施应根据施工经验确定",{"key":24,"text":701,"correct":22},"燃气管道宜采用钢管",{"key":27,"text":703,"correct":29},"燃气管道至规划河底的覆土厚度应根据管径大小确定",{"key":31,"text":705,"correct":22},"在埋设燃气管道位置的河流两岸上、下游应设立标志",{"key":34,"text":707,"correct":22},"燃气管道对接安装引起的误差不得大于3°，否则应设置弯管","BDE",{"id":710,"libraryId":5,"type":15,"typeLabel":16,"stem":711,"options":712,"answer":366,"analysis":37},1127212,"燃气管道的阀门安装前应做( )试验。",[713,715,717,718,720],{"key":20,"text":714,"correct":22},"强度",{"key":24,"text":716,"correct":22},"严密性",{"key":27,"text":624,"correct":29},{"key":31,"text":719,"correct":29},"耐腐蚀",{"key":34,"text":721,"correct":29},"可靠性",[723,727,730,733,736,739],{"id":724,"name":725,"category":7,"favorite":726},1,"领导干部任职前廉政法规知识测试题",92,{"id":728,"name":729,"category":7,"favorite":724},595,"建筑结构与设备",{"id":731,"name":732,"category":7,"favorite":724},715,"招标采购专业知识与法律法规",{"id":734,"name":735,"category":7,"favorite":724},848,"市政方向-通用基础",{"id":737,"name":738,"category":7,"favorite":8},534,"BIM工程师",{"id":740,"name":738,"category":7,"favorite":8},535]