[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-792-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":602},{"id":5,"name":6,"category":7,"favorite":8},792,"二建市政工程实务","建筑工程",0,5,50,2846,[13,34,46,58,70,82,94,106,118,130,142,154,162,174,186,198,209,221,233,245,257,269,281,291,303,315,327,339,351,363,375,387,399,411,423,435,447,456,466,475,485,497,509,521,530,542,554,566,578,590],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1124675,1,"单选题","关于砖砌拱圈表述错误的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","砌筑前，拱胎应充分湿润，冲洗干净，并涂刷隔离剂",false,{"key":24,"text":25,"correct":22},"B","砌筑应自两侧向拱中心对称进行",{"key":27,"text":28,"correct":22},"C","应采用退槎法砌筑，每块砌块退半块留槎",{"key":30,"text":31,"correct":32},"D","拱圈应在2d内封顶，拱顶上可堆置轻型器材",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1124676,"关于砌筑沟道施工要求错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":32},"砌筑砂浆应采用混合砂浆",{"key":24,"text":41,"correct":22},"砌筑前砌块应充分湿润",{"key":27,"text":43,"correct":22},"砌筑应采用满铺满挤法",{"key":30,"text":45,"correct":22},"沉降缝.变形缝应与基础的沉降缝.变形缝贯通",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1124677,"下列选项中，对于压力管道水压试验的说法不正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"试验管段内所有敞口应封闭，不得渗漏",{"key":24,"text":53,"correct":32},"试验管段内可以用闸阀做堵板",{"key":27,"text":55,"correct":22},"水压试验前应清除管道内杂物",{"key":30,"text":57,"correct":22},"应做好水源引接.排水等疏导方案",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},1124678,"地下管道不开槽施工与开槽施工相比，其弱项是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"土方开挖和回填工作量",{"key":24,"text":65,"correct":22},"冬.雨期对施工的影响",{"key":27,"text":67,"correct":22},"对管道沿线的环境影响",{"key":30,"text":69,"correct":32},"管道轴线与标高的控制",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1124679,"给水排水管道功能性试验时，试验段的划分应符合的要求中不正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"无压力管道的闭水试验宜带井试验",{"key":24,"text":77,"correct":32},"当管道采用两种（或两种以上）管材时，不必按管材分别进行试验",{"key":27,"text":79,"correct":22},"无压力管道的闭水试验一次试验不可超过5个连续井段",{"key":30,"text":81,"correct":22},"压力管道水压试验的管段长度不宜大于1.0km",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1124680,"采用混凝土砌块砌筑拱形管渠或管渠的弯道时，宜采用（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"楔形或梯形砌块",{"key":24,"text":89,"correct":32},"楔形或扇形砌块",{"key":27,"text":91,"correct":22},"楔形或方形砌块",{"key":30,"text":93,"correct":22},"条形或扇形砌块",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},1124682,"关于破管顶进优缺点表述错误的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"对地表和土层无干扰",{"key":24,"text":101,"correct":22},"可在复杂的土层中施工，尤其是含水层",{"key":27,"text":103,"correct":32},"不需开挖工作井即可施工",{"key":30,"text":105,"correct":22},"能够更换管线的走向和坡度已偏离的管道",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1124683,"缠绕法的缺点是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"管道严重变形时施工难以进行",{"key":24,"text":113,"correct":32},"管道的过流断面会有损失",{"key":27,"text":115,"correct":22},"环形间隙要求灌浆",{"key":30,"text":117,"correct":22},"树脂固化需要一定的时间",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},1124684,"施工精度高，适用于各种土层的不开槽管道施工方法是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"夯管",{"key":24,"text":125,"correct":22},"定向钻",{"key":27,"text":127,"correct":22},"浅埋暗挖",{"key":30,"text":129,"correct":32},"密闭式顶管",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},1124685,"对接管口时，应检查管道平直度，在距接口中心200mm处测量，允许偏差（ ）mm。",[134,136,138,140],{"key":20,"text":135,"correct":32},"0～1",{"key":24,"text":137,"correct":22},"0～2",{"key":27,"text":139,"correct":22},"0～3",{"key":30,"text":141,"correct":22},"0～4",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1124686,"某热力管道保温棉毡厚12cm，至少应分为（ ）层施工。",[146,148,150,152],{"key":20,"text":147,"correct":22},"1",{"key":24,"text":149,"correct":32},"2",{"key":27,"text":151,"correct":22},"3",{"key":30,"text":153,"correct":22},"4",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},1124687,"热力管道同一部位焊缝的返修次数不得超过（ ）次。",[158,159,160,161],{"key":20,"text":147,"correct":22},{"key":24,"text":149,"correct":32},{"key":27,"text":151,"correct":22},{"key":30,"text":153,"correct":22},{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":27,"analysis":33},1124688,"所有阀门手轮高于地面（ ）m的需要加设操作平台。",[166,168,170,172],{"key":20,"text":167,"correct":22},"1.2",{"key":24,"text":169,"correct":22},"1.4",{"key":27,"text":171,"correct":32},"1.6",{"key":30,"text":173,"correct":22},"1.8",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":33},1124689,"关于供热管道套管的安装要求，穿过结构的套管长度每侧应大于墙厚（ ）mm。",[178,180,182,184],{"key":20,"text":179,"correct":32},"20",{"key":24,"text":181,"correct":22},"25",{"key":27,"text":183,"correct":22},"30",{"key":30,"text":185,"correct":22},"35",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},1124690,"换热站内管道安装的最小坡度为（ ），在管道高点设置放气装置，低点设置放水装置。",[190,192,194,196],{"key":20,"text":191,"correct":22},"3‰",{"key":24,"text":193,"correct":32},"2‰",{"key":27,"text":195,"correct":22},"1.5‰",{"key":30,"text":197,"correct":22},"1‰",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":24,"analysis":33},1124691,"对接热力管道管口时，应检查管道平直度，在所对接管子的全长范围内，最大偏差值应不超过（ ）mm。",[202,204,206,208],{"key":20,"text":203,"correct":22},"5",{"key":24,"text":205,"correct":32},"10",{"key":27,"text":207,"correct":22},"15",{"key":30,"text":179,"correct":22},{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":20,"analysis":33},1124692,"热力管网试运行的时间应在达到试运行的参数条件下连续运行（ ）h。",[213,215,217,219],{"key":20,"text":214,"correct":32},"72",{"key":24,"text":216,"correct":22},"60",{"key":27,"text":218,"correct":22},"48",{"key":30,"text":220,"correct":22},"36",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":27,"analysis":33},1124693,"高温热水热网的温度大于（ ）℃。",[225,227,229,231],{"key":20,"text":226,"correct":22},"90",{"key":24,"text":228,"correct":22},"95",{"key":27,"text":230,"correct":32},"100",{"key":30,"text":232,"correct":22},"105",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":27,"analysis":33},1124694,"关于管道定位焊的说法，错误的是（ ）。",[237,239,241,243],{"key":20,"text":238,"correct":22},"采用与根部焊道相同的焊接材料",{"key":24,"text":240,"correct":22},"采用与根部焊道相同的焊接工艺",{"key":27,"text":242,"correct":32},"在螺旋管焊缝的端部应进行定位焊",{"key":30,"text":244,"correct":22},"定位焊缝是正式焊缝",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":27,"analysis":33},1124695,"有补偿器装置的热力管道，在补偿器安装前，管道和（ ）不得进行固定连接。",[249,251,253,255],{"key":20,"text":250,"correct":22},"导向支架",{"key":24,"text":252,"correct":22},"悬吊支架",{"key":27,"text":254,"correct":32},"固定支架",{"key":30,"text":256,"correct":22},"滚动支架",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":30,"analysis":33},1124696,"按敷设方式分热力网最常见的为：管沟敷设、直埋敷设、（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":22},"顶管铺设",{"key":24,"text":264,"correct":22},"浅埋暗挖敷设",{"key":27,"text":266,"correct":22},"盾构敷设",{"key":30,"text":268,"correct":32},"架空敷设",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":27,"analysis":33},1124697,"关于阀门安装的规定，说法正确的是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":22},"阀门进场前只进行强度试验",{"key":24,"text":276,"correct":22},"水平安装的闸阀.截止阀的阀杆应处于下半周范围内",{"key":27,"text":278,"correct":32},"并排安装的阀门应整齐.美观，便于操作",{"key":30,"text":280,"correct":22},"阀门吊装应平稳，用阀门手轮作为吊装的承重点",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":30,"analysis":33},1124698,"形式较复杂，使用在重要场合的支架是（ ）。",[285,286,288,289],{"key":20,"text":254,"correct":22},{"key":24,"text":287,"correct":22},"滑动支架",{"key":27,"text":250,"correct":22},{"key":30,"text":290,"correct":32},"弹簧支架",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":30,"analysis":33},1124699,"固定支架安装的表述中，错误的是（ ）。",[295,297,299,301],{"key":20,"text":296,"correct":22},"固定支架.导向支架等型钢支架的根部，应做防水护墩",{"key":24,"text":298,"correct":22},"固定支架卡板和支架结构接触面应贴实，但不得焊接，以免形成“死点”",{"key":27,"text":300,"correct":22},"管道与固定支架.滑托等焊接时，不得损伤管道母材",{"key":30,"text":302,"correct":32},"有轴向补偿器的管段，补偿器安装前，管道和固定支架之间可以先进行固定",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":20,"analysis":33},1124700,"当阀门与管道以法兰或螺纹方式连接时，阀门应在（ ）状态下安装。",[307,309,311,313],{"key":20,"text":308,"correct":32},"关闭",{"key":24,"text":310,"correct":22},"打开1／3",{"key":27,"text":312,"correct":22},"半开",{"key":30,"text":314,"correct":22},"全开",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":20,"analysis":33},1124701,"滑动支架支撑表面的标高可采用（ ）调整。",[319,321,323,325],{"key":20,"text":320,"correct":32},"加设不大于两层金属垫板",{"key":24,"text":322,"correct":22},"加设不大于两层硬木垫板",{"key":27,"text":324,"correct":22},"加设不大于一层金属垫板",{"key":30,"text":326,"correct":22},"加设不大于一层硬木垫板",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":24,"analysis":33},1124702,"一次热网与二次热网用换热器相连，一次管网热媒损失小，但中间设备多,使用较广泛的是（ ）系统。",[331,333,335,337],{"key":20,"text":332,"correct":22},"开式",{"key":24,"text":334,"correct":32},"闭式",{"key":27,"text":336,"correct":22},"低温",{"key":30,"text":338,"correct":22},"高温",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":33},1124703,"关于热力管网中补偿器作用的说法，不正确的是（ ）。",[343,345,347,349],{"key":20,"text":344,"correct":22},"释放温度变形",{"key":24,"text":346,"correct":32},"便于设备及管件的拆装维护",{"key":27,"text":348,"correct":22},"消除温度应力",{"key":30,"text":350,"correct":22},"确保管网运行安全",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":33},1124704,"供热管道分类中，从热源到换热站的管道系统称为（ ）。",[355,357,359,361],{"key":20,"text":356,"correct":32},"一级管网",{"key":24,"text":358,"correct":22},"二级管网",{"key":27,"text":360,"correct":22},"供水管",{"key":30,"text":362,"correct":22},"开式系统",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":30,"analysis":33},1124705,"蒸汽冲洗管道表述错误的是（ ）。",[367,369,371,373],{"key":20,"text":368,"correct":22},"蒸汽吹洗的排汽管应引出室外，管口不得朝下并设临时固定支架",{"key":24,"text":370,"correct":22},"吹洗出口管在有条件情况下，以斜上方45°为宜，距出口100m范围内，不得有人工作或有怕烫建筑物",{"key":27,"text":372,"correct":22},"蒸汽吹洗前应缓慢升温进行暖管，暖管速度不宜过快",{"key":30,"text":374,"correct":32},"暖管时阀门应迅速打开",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":24,"analysis":33},1124706,"支、吊架安装的规定表述中，错误的是（ ）。",[379,381,383,385],{"key":20,"text":380,"correct":22},"支架结构接触面应洁净.平整",{"key":24,"text":382,"correct":32},"临时性的支.吊架应做出明显标记，并应在管道安装过程中进行拆除",{"key":27,"text":384,"correct":22},"支.吊架的焊接，焊缝不得有漏焊.缺焊.咬边或裂纹等缺陷",{"key":30,"text":386,"correct":22},"管道支架支承面的标高可采用加设金属垫板的方式进行调整",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":20,"analysis":33},1124708,"热水热网按热媒温度可分为两类，其中热媒温度（ ）℃属于高温热水管网。",[391,393,395,397],{"key":20,"text":392,"correct":32},"＞100",{"key":24,"text":394,"correct":22},"≥100",{"key":27,"text":396,"correct":22},"＞95",{"key":30,"text":398,"correct":22},"≥95",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":24,"analysis":33},1124709,"换热站内所有系统均应进行严密性试验，试验压力是设计压力的（ ）倍，且不得低于（ ）MPa。",[403,405,407,409],{"key":20,"text":404,"correct":22},"1.25；0.5",{"key":24,"text":406,"correct":32},"1.25；0.6",{"key":27,"text":408,"correct":22},"1.5；0.5",{"key":30,"text":410,"correct":22},"1.5；0.6",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":24,"analysis":33},1124710,"燃气管道进行严密性试验时，设计输气压力为0.1MPa，试验压力应为（ ）。",[415,417,419,421],{"key":20,"text":416,"correct":22},"20kPa",{"key":24,"text":418,"correct":32},"0.115 MPa",{"key":27,"text":420,"correct":22},"0.1MPa",{"key":30,"text":422,"correct":22},"0.6MPa",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":27,"analysis":33},1124711,"埋设在车行道下的地下燃气管道的最小覆土厚度不得小于（ ）。",[427,429,431,433],{"key":20,"text":428,"correct":22},"0. 3m",{"key":24,"text":430,"correct":22},"0. 6m",{"key":27,"text":432,"correct":32},"0. 9m",{"key":30,"text":434,"correct":22},"1. 2m",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":33},1124712,"燃气管道的吹扫压力不得大于管道的设计压力，且应不大于（ ）MPa。",[439,441,443,445],{"key":20,"text":440,"correct":22},"0.1",{"key":24,"text":442,"correct":32},"0.3",{"key":27,"text":444,"correct":22},"0.5",{"key":30,"text":446,"correct":22},"1.0",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":24,"analysis":33},1124713,"燃气管道穿越不通航河流河底时，根据水流冲刷条件确定管道至规划河底的覆土厚度不应小于（ ）m。",[451,452,453,455],{"key":20,"text":442,"correct":22},{"key":24,"text":444,"correct":32},{"key":27,"text":454,"correct":22},"0.8",{"key":30,"text":446,"correct":22},{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":24,"analysis":33},1124714,"地下燃气管道埋设在非车行道（含人行道）下时，最小覆土厚度为（ ）m。",[460,461,463,464],{"key":20,"text":442,"correct":22},{"key":24,"text":462,"correct":32},"0.6",{"key":27,"text":454,"correct":22},{"key":30,"text":465,"correct":22},"0.9",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":24,"analysis":33},1124715,"地下燃气管道与直埋热力管的水平净距不得小于（ ）m。",[470,471,472,473],{"key":20,"text":444,"correct":22},{"key":24,"text":446,"correct":32},{"key":27,"text":167,"correct":22},{"key":30,"text":474,"correct":22},"1.5",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":24,"analysis":33},1124716,"对绝缘法兰进行绝缘试验检查时，绝缘电阻不得小于（ ）MΩ。",[479,480,481,483],{"key":20,"text":444,"correct":22},{"key":24,"text":446,"correct":32},{"key":27,"text":482,"correct":22},"2.0",{"key":30,"text":484,"correct":22},"2.5",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},1124717,"埋地燃气管道，当设计输气压力为1.0MPa，其严密性试验压力为（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"1.0MPa",{"key":24,"text":492,"correct":32},"1.15MPa",{"key":27,"text":494,"correct":22},"1.5MPa",{"key":30,"text":496,"correct":22},"1.2MPa",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":20,"analysis":33},1124718,"警示带的字体不宜小于（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":32},"100mm×100mm",{"key":24,"text":504,"correct":22},"150mm×150mm",{"key":27,"text":506,"correct":22},"200mm×200mm",{"key":30,"text":508,"correct":22},"250mm×250mm",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},1124719,"沥青涂料涂刷温度不得低于（ ）℃。",[513,515,517,519],{"key":20,"text":514,"correct":32},"180",{"key":24,"text":516,"correct":22},"200",{"key":27,"text":518,"correct":22},"220",{"key":30,"text":520,"correct":22},"240",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":24,"analysis":33},1124720,"高压旋喷桩加固体的有效直径或范围应根据现场试验或工程经验确定。当用于止水帷幕时，加固体的搭接应大于（ ）cm。",[525,526,527,528],{"key":20,"text":181,"correct":22},{"key":24,"text":183,"correct":32},{"key":27,"text":185,"correct":22},{"key":30,"text":529,"correct":22},"40",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":27,"analysis":33},1124721,"燃气管道作水压强度试验时，当压力达到规定值后，应稳压（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":22},"3h",{"key":24,"text":537,"correct":22},"2h",{"key":27,"text":539,"correct":32},"1h",{"key":30,"text":541,"correct":22},"4h",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":27,"analysis":33},1124722,"燃气管道中，防腐前钢管表面的处理等级不低于（ ）级。",[546,548,550,552],{"key":20,"text":547,"correct":22},"Sa1",{"key":24,"text":549,"correct":22},"Sa2",{"key":27,"text":551,"correct":32},"Sa2.5",{"key":30,"text":553,"correct":22},"Sa3",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":30,"analysis":33},1124723,"下列不属于燃气管道性能要求的是（ ）。",[558,560,562,564],{"key":20,"text":559,"correct":22},"不透气性",{"key":24,"text":561,"correct":22},"冲击韧性",{"key":27,"text":563,"correct":22},"延伸率",{"key":30,"text":565,"correct":32},"抗冻性",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":20,"analysis":33},1124724,"干管及支管的末端连接城市或大型工业企业，作为供应区气源点的是（ ）管道。",[570,572,574,576],{"key":20,"text":571,"correct":32},"长距离输气",{"key":24,"text":573,"correct":22},"城市燃气",{"key":27,"text":575,"correct":22},"工业企业燃气",{"key":30,"text":577,"correct":22},"炉前燃气",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":20,"analysis":33},1124725,"输气压力为1.2MPa燃气管道为（ ）燃气管道。",[582,584,586,588],{"key":20,"text":583,"correct":32},"次高压A",{"key":24,"text":585,"correct":22},"次高压B",{"key":27,"text":587,"correct":22},"高压A",{"key":30,"text":589,"correct":22},"高压B",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":20,"analysis":33},1124726,"关于燃气管道利用道路桥梁跨越河流的要求，错误的是（ ）。",[594,596,598,600],{"key":20,"text":595,"correct":32},"次高压B管道可以随桥跨越河流",{"key":24,"text":597,"correct":22},"管道应设置必要的补偿和减震措施",{"key":27,"text":599,"correct":22},"敷设于桥梁上的燃气管道应对焊缝进行100%无损探伤",{"key":30,"text":601,"correct":22},"对管道应做较高等级的防腐保护",[603,606,609,612,615,618],{"id":15,"name":604,"category":7,"favorite":605},"领导干部任职前廉政法规知识测试题",92,{"id":607,"name":608,"category":7,"favorite":15},595,"建筑结构与设备",{"id":610,"name":611,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":613,"name":614,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":616,"name":617,"category":7,"favorite":8},534,"BIM工程师",{"id":619,"name":617,"category":7,"favorite":8},535]