[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1127211":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1127211,792,2,"多选题","燃气管道穿越河底时，应符合( )等要求。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","稳管措施应根据施工经验确定",false,{"key":16,"text":17,"correct":18},"B","燃气管道宜采用钢管",true,{"key":20,"text":21,"correct":14},"C","燃气管道至规划河底的覆土厚度应根据管径大小确定",{"key":23,"text":24,"correct":18},"D","在埋设燃气管道位置的河流两岸上、下游应设立标志",{"key":26,"text":27,"correct":18},"E","燃气管道对接安装引起的误差不得大于3°，否则应设置弯管","BDE","2021\u002F2020版教材P164 城镇燃气管道工程施工与安装。（8）燃气管道穿越河底时，应符合下列要求：1）燃气管宜采用钢管2）燃气管道至规划河底的覆土厚度，应根据水流冲刷条件确定，对不通航河流不应小于0.5m；对通航的河流不应小于1.0m，还应考虑疏浚和投锚深度。3）稳管措施应根据计算确定4）在埋设燃气管道位置的河流两岸上、下游应设立标志。5）燃气管道对接安装引起的误差不得大于3°，否则应设置弯管，次高压燃气管道的弯管应考虑盲板力。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]