[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1127142":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1127142,792,2,"多选题","设计蓄水深6m的圆形现浇预应力混凝土无盖水池进行满水试验，正确的做法有( )。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","分3次向水池中注水，每次水位上升2m",true,{"key":16,"text":17,"correct":14},"B","每次注水时间应不少于24h",{"key":19,"text":20,"correct":14},"C","水池渗水量过大时应停止注水，进行处理",{"key":22,"text":23,"correct":24},"D","本水池可不测定蒸发量",false,{"key":26,"text":27,"correct":14},"E","满水试验应在池体的防水层、防腐层施工之前进行","ABCE","2021\u002F2020版教材P131 (1)向池内注水宜分3次进行，每次注水为设计水深的1\u002F3，6m即为2m，A对。(2)注水时水位上升速度不宜超过2m\u002Fd。相邻两次注水的间隔时间不应小于24h。(3)当发现渗水量过大时，应停止注水。待做出妥善处理后方可继续注水，C对。(3)注水至设计水深24h后，开始测读水位测针的初读数。(4)测读水位的初读数与末读数之间的间隔时间应不少于24h，B对。(2)池体无盖时，需作蒸发量测定，D错。P106：(2)现浇钢筋混凝土池体的防水层、防腐层施工之前；E对。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]