[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1127103":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1127103,792,2,"多选题","用高压喷射法加固地基时，应根据现场试验结果确定其适用程度的土层有（）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","湿陷性黄土",true,{"key":16,"text":17,"correct":18},"B","素填土",false,{"key":20,"text":21,"correct":14},"C","有机质土",{"key":23,"text":24,"correct":18},"D","碎石土",{"key":26,"text":27,"correct":14},"E","硬黏土","ACE","P89-93 高压喷射注浆法对淤泥、淤泥质土、黏性土(流塑、软塑和可塑)、粉土、砂土、黄土、素填土和碎石土等地基处理都有良好的处理效果。但是对于硬黏性土，含有较多的块石或大量植物根茎的地基，因喷射流可能受到阻碍或削弱，使冲击破碎力急剧下降，切削范围小或影响效果。而对于含有过多有机质的土层，其处理效果取决于固结体的化学稳定性。鉴于上述几种土的组成复杂、差异悬殊，高压喷射注浆处理的效果差别较大，应根据现场试验结果确定其适用程度。对于湿陷性黄土地基，也应预先进行现场试验。对于硬黏土，有机土，湿陷性黄土地基，应预先进行现场试验，确定是否有效。 注：题干是问的应根据现场试验结果确定其适用程度的土层。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]