[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1127064":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1127064,792,2,"多选题","小导管注浆是浅埋暗挖隧道超前支护的一种措施，其应用条件有( )。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","在软弱、破碎地层中凿孔后易塌孔，且施作超前锚杆比较困难或者结构断面较大时",true,{"key":16,"text":17,"correct":14},"B","在软弱、破碎地层中凿孔时，若条件允许，可在地面进行超前注浆加固",{"key":19,"text":20,"correct":14},"C","超前小导管支护必须配合钢拱架使用",{"key":22,"text":23,"correct":14},"D","在软弱、破碎地层中凿孔时，可在导洞内对隧道周边进行径向注浆加固",{"key":25,"text":26,"correct":27},"E","在软弱、破碎地层中凿孔时，可在导洞内对隧道周边进行环向注浆加固",false,"ABCD","2021\u002F2020版教材P114页 在软弱、破碎地层中成孔困难或易塌孔，且施作超前锚杆比较困难或者结构断面较大时，宜采取超前小导管注浆和超前预加固处理方法。小导管支护和超前加固必须配合钢拱架使用。在条件允许时，应配合地面超前注浆加固；有导洞时，可在导洞内对隧道周边进行径向注浆加固。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]