[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1127012":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1127012,792,2,"多选题","宜采用一级双排真空井点，布置在基坑两侧降水的前提条件有（）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","真空井点孔口至设计降水水位的深度不超过6.0M",true,{"key":16,"text":17,"correct":14},"B","基坑土质为粉质黏土、粉土、砂土",{"key":19,"text":20,"correct":14},"C","土层渗透系数0.01~20.0m\u002Fd",{"key":22,"text":23,"correct":24},"D","土层渗透系数0.1~20.0m\u002Fd",false,{"key":26,"text":27,"correct":14},"E","基坑宽度大于单井降水影响半径","ABCE","2021\u002F2020版教材P86~87页 3)降水井点围合区域宽度大于单井降水影响半径或采用隔水帷幕的工程。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]