[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1126975":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1126975,792,2,"多选题","关于钻孔桩钢筋笼与混凝土灌注施工要点，错误的有（）",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","钢筋笼制作、运输和吊装过程中应防止其变形",false,{"key":16,"text":17,"correct":18},"B","钢筋笼放入泥浆后5h内必须浇筑混凝土",true,{"key":20,"text":21,"correct":18},"C","宜采用预拌混凝土，其骨料粒径不宜大于45mm",{"key":23,"text":24,"correct":14},"D","浇筑时混凝土的温度不得低于5℃",{"key":26,"text":27,"correct":14},"E","当气温高于30℃时，应根据具体情况对混凝土采取缓凝措施","BC","P56-60 (1)钢筋笼加工应符合设计要求。钢筋笼制作、运输和吊装过程中应采取适当的加固措施，防止变形。 (2)灌注桩采用的水下灌注混凝土宜采用预拌混凝土，其骨料粒径不宜大于40mm。 (3)灌注桩各工序应连续施工，钢筋笼放入泥浆后4h内必须浇筑混凝土。 (4)当气温低于0℃时，浇筑混凝土应采取保温措施，浇筑时混凝土的温度不得低于5℃。当气温高于30℃时，应根据具体情况对混凝土采取缓凝措施。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]