[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1126912":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1126912,792,2,"多选题","下列预应力张拉施工规定中，正确的有( )。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","预应力筋的张拉控制应力必须符合设计规定",true,{"key":16,"text":17,"correct":14},"B","预应力筋采用应力控制方法张拉时，应以伸长值进行校核",{"key":19,"text":20,"correct":14},"C","伸长值应从初应力时开始量测",{"key":22,"text":23,"correct":14},"D","实际伸长值与理论伸长值的差值应符合设计要求",{"key":25,"text":26,"correct":27},"E","设计无规定时，实际伸长值与理论伸长值之差应控制在8%以内",false,"ABCD","2021\u002F2020版教材P44页 预应力筋张拉的基本规定：（1）预应力筋张拉控制应力必须符合设计规定（2）预应力筋采用应力控制方法张拉时，应以伸长值进行校核。实际伸长值与理论伸长值的差值应符合设计要求；设计无规定时，实际伸长值与理论伸长值的差值应控制在6%以内（3）伸长值应从初应力时量测",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]