[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1126852":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1126852,792,2,"多选题","关于混凝土结构水处理构筑物质量验收主控项目的说法，正确的有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","水处理构筑物结构类型、结构尺寸应符合设计要求",true,{"key":16,"text":17,"correct":14},"B","预埋件、预留孔洞、止水带等规格、尺寸应符合设计要求",{"key":19,"text":20,"correct":14},"C","混凝土强度、抗渗、抗冻性能符合设计要求",{"key":22,"text":23,"correct":24},"D","混凝土结构外观无一般质量缺陷",false,{"key":26,"text":27,"correct":14},"E","构筑物外壁不得渗水","ABCE","P279-281 混凝土结构水处理构筑物质量验收主控项目： (1)水处理构筑物结构类型、结构尺寸以及预埋件、预留孔洞、止水带等规格、尺寸应符合设计要求。 (2)混凝土强度符合设计要求; 混凝土抗渗、抗冻性能符合设计要求。 (3)混凝土结构外观无严重质量缺陷。 (4)构筑物外壁不得渗水。 (5)构筑物各部位以及预埋件、预留孔洞、止水带等的尺寸、位置、高程、线形等的偏差，不得影响结构性能和水处理工艺的平面布置、设备安装、水力条件。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]