[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1126679":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1126679,792,2,"多选题","设计蓄水深6m的圆形现浇预应力混凝土无盖水池进行满水试验，正确的做法有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","分3次向水池中注水，每次水位上升2m\u002Fd",true,{"key":16,"text":17,"correct":14},"B","每次注水间隔时间应不少于24h",{"key":19,"text":20,"correct":14},"C","水池渗水量过大时应停止注水，进行处理",{"key":22,"text":23,"correct":24},"D","本水池可不测定蒸发量",false,{"key":26,"text":27,"correct":14},"E","满水试验应在池体的防水层、防腐层施工之前进行","ABCE","现浇钢筋混凝土水池应在池体的防水层、防腐层施工之前进行水池满水试验。向池内注水分3次进行，每次注入为设计水深的1\u002F3注水，水位上升速度不超过2m\u002Fd，相邻两次充水的间隔时间，应不少于24h。每次注水后宜测读24h的水位下降值。在充水过程中和注水以后，应对池外观、沉降量进行检查，渗水量或沉降量过大时应停止充水，待作出妥善处理后方可继续注水。有盖水池的满水试验，对蒸发量可忽略不计。无盖水池的满水试验时应测蒸发量。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]