[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1126586":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1126586,792,2,"多选题","关于灌注桩水下混凝土灌注用导管要求的说法，正确的有( )。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","导管直径宜为20～30cm，节长宜为3m",false,{"key":16,"text":17,"correct":14},"B","导管不得漏水，试压的压力宜为孔底静水压力的1.2倍",{"key":19,"text":20,"correct":21},"C","导管采用法兰盘接头宜加锥形活套",true,{"key":23,"text":24,"correct":21},"D","导管轴线偏差不宜超过孔深的0.5%，且不宜大于10cm",{"key":26,"text":27,"correct":21},"E","采用螺旋丝扣型接头时必须有防止松脱装置","CDE","导管应符合下列要求： （1）导管直径宜为20～30cm，节长宜为2m； （2）导管不得漏水，使用前应试拼、试压，试验压力为孔内水深1.5倍压力； （3）导管轴线偏差不宜超过孔深的0.5%，且不宜大于10cm （4）导管采用法兰盘接头宜加锥形活套，采用螺旋丝扣型接头时必须有防止松脱装置。",{"id":6,"name":31,"category":32,"favorite":33},"二建市政工程实务","建筑工程",0]