[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1125512":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1125512,792,1,"单选题","燃气管道吹扫有气体吹扫或清管球清扫，下列选项中对于气体清扫表述正确的是( )。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","公称直径大于或等于100mm的钢质管道，宜采用气体进行清扫",false,{"key":16,"text":17,"correct":14},"B","吹扫压力不得大于管道的设计压力，且应不大于0.5MPa",{"key":19,"text":20,"correct":21},"C","吹扫气体流速不宜小于20m／s，吹扫口与地面的夹角应在30~45°之间",true,{"key":23,"text":24,"correct":14},"D","吹扫介质宜采用真空空气，严禁采用氧气和可燃性气体","2021\u002F2020版教材P173 一）管道吹扫1.管道吹扫应按下列要求选择气体吹扫或清管球清扫：（2）公称直径大于或等于100mm的钢质管道，宜采用清管球进行清扫，所以A选项错误2.管道吹扫应符合下列要求：（6）吹扫压力不得大于管道的设计压力，且应不大于0.3MPa，所以B选项错误（7）吹扫介质宜采用压缩空气，严禁采用氧气和可燃性气体，所以D选项错误3.气体吹扫应符合下列要求：（1）吹扫气体流速不宜小于20m\u002Fs（2）吹扫口与地面的夹角应在30°～45°之间.",{"id":6,"name":27,"category":28,"favorite":29},"二建市政工程实务","建筑工程",0]