[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1125503":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},1125503,792,1,"单选题","采用阴极保护的埋地钢管与随桥燃气管道之间应设置( )装置。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","绝缘",true,{"key":16,"text":17,"correct":18},"B","接地",false,{"key":20,"text":21,"correct":18},"C","消磁",{"key":23,"text":24,"correct":18},"D","绝热","2021\u002F2020版教材P164 燃气管道随桥梁敷设宜采取的安全防护措施。燃气管道随桥梁敷设，宜采取如下安全防护措施：(1)敷设于桥梁上的燃气管道应采用加厚的无缝钢管或焊接钢管，尽量减少焊缝，对焊缝进行100%无损探伤。(2)跨越通航河流的燃气管道管底高程，应符合通航净空的要求，管架外侧应设置护桩。(3)在确定管道位置时，应与随桥敷设的其他可燃气体管道保持一定间距。(4)管道应设置必要的补偿和减震措施。(5)过河架空的燃气管道向下弯曲时，向下弯曲部分与水平管夹角宜采用45°形式。(6)对管道应做较高等级的防腐保护。(7)采用阴极保护的埋地钢管与随桥管道之间应设置绝缘装置。",{"id":6,"name":27,"category":28,"favorite":29},"二建市政工程实务","建筑工程",0]