[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1125468":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},1125468,792,1,"单选题","一级管网及二级管网应进行强度试验和严密性试验。强度试验压力应为( )倍的设计压力，严密性试验压力应为( )倍设计压力，且不得低于（）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","1.25；1.5；0.6MPa",false,{"key":16,"text":17,"correct":14},"B","1.5；1.25；0.4MPa",{"key":19,"text":20,"correct":14},"C","1.5；1.25；0.5MPa",{"key":22,"text":23,"correct":24},"D","1.5；1.25；0.6MPa",true,"2021\u002F2020版教材P159 一供热管道功能性试验的规定一级管网及二级管网强度试验压力应为1.5倍的设计压力，严密性试验压力应为1.25倍设计压力，且不得低于0.6MPa。",{"id":6,"name":27,"category":28,"favorite":29},"二建市政工程实务","建筑工程",0]