[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1125467":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},1125467,792,1,"单选题","某供热管网设计压力为0.4MPa，其严密性试验压力为( )MPa。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","0.42",false,{"key":16,"text":17,"correct":14},"B","0.46",{"key":19,"text":20,"correct":14},"C","0.50",{"key":22,"text":23,"correct":24},"D","0.60",true,"2021\u002F2020版教材P159 供热管道功能性试验的规定。一级管网及二级管网应进行强度试验和严密性试验。强度试验的试验压力为1.5倍设计压力，且不得低于0.6MPa，其目的是试验管道本身与安装时焊口的强度；严密性试验的试验压力为1.25倍设计压力，且不得低于0.6MPa，它是在各管段强度试验合格的基础上进行的，且应该是在管道安装内容全部完成（如零件、法兰等）以及施焊工序全部完成后进行。这种试验是对管道的一次全面检验。",{"id":6,"name":27,"category":28,"favorite":29},"二建市政工程实务","建筑工程",0]