[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1125393":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},1125393,792,1,"单选题","构筑物水池满水试验，池内水位注至设计水位24h后，开始测读水位测针的初读数。水位观测的正确做法是（）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","测读水位末读数与初读数的时间间隔应不小于24h。水位测针读数精度应达到0．01mm",false,{"key":16,"text":17,"correct":14},"B","测读水位末读数与初读数的时间间隔可以根据现场情况而定。水位测针读数精度应达到0．1mm",{"key":19,"text":20,"correct":14},"C","测读水位末读数与初读数的时间间隔应不小于48h。水位测针读数精度应达到0．1mm",{"key":22,"text":23,"correct":24},"D","测读水位末读数与初读数的时间间隔应不小于24h。水位测针的读数精度应达到0．1mm",true,"P131-132 水位观测: (1)利用水位标尺测针观测、记录注水时的水位值。 (2)注水至设计水深进行渗水量测定时，应采用水位测针测定水位。水位测针的读数精确度应达0.1mm。 (3)注水至设计水深24h后，开始测读水位测针的初读数。 (4)测读水位的初读数与末读数之间的间隔时间应不少于24h。 (5)测定时间必须连续。测定的渗水量符合标准时，需连续测定两次以上；测定的渗水量超过允许标准，而以后的渗水量逐渐减少时，可继续延长观测。延长观测的时间应在渗水量符合标准时止。",{"id":6,"name":27,"category":28,"favorite":29},"二建市政工程实务","建筑工程",0]