[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1124562":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},1124562,792,1,"单选题","关于真空井点施工安装的说法，正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","井点管的成孔达到设计孔深后，应减小泵量、冲洗钻孔、稀释泥浆",false,{"key":16,"text":17,"correct":18},"B","井点管安装到位后，向孔内投放的滤料粒径宜为0.4mm~0.6mm",true,{"key":20,"text":21,"correct":14},"C","井点管严禁与水泵连接安装，抽水系统不应漏水、漏气",{"key":23,"text":24,"correct":14},"D","真空井点布设完成后立即开始进行降水作业","真空井点施工安装应符合下列规定： （1）井点管的成孔达到上条要求及设计孔深后，应加大泵量、冲洗钻孔、稀释泥浆，返清水3min~5min后，方可向孔内安放井点管； （2）井点管安装到位后，应向孔内投放滤料，滤料粒径宜为0.4mm~0.6mm。孔内投入的滤料数量，宜大于计算值5％～15%，滤料填至地面以下1m~2m后应用黏土填满压实； （3）井点管、集水总管应与水泵连接安装，抽水系统不应漏水、漏气； （4）形成完整的真空井点抽水系统后，应进行试运行。",{"id":6,"name":27,"category":28,"favorite":29},"二建市政工程实务","建筑工程",0]