[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1124388":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1124388,791,2,"多选题","防止瓦斯引燃引爆的主要措施有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","严禁携带烟草和点火物品下井",true,{"key":16,"text":17,"correct":14},"B","防止爆破引燃引爆瓦斯",{"key":19,"text":20,"correct":14},"C","防止机械摩擦火花引燃瓦斯",{"key":22,"text":23,"correct":24},"D","人井人员严禁穿纯棉衣服",false,{"key":26,"text":27,"correct":24},"E","井下应采用气焊和喷灯焊接","ABC","P237-241 防止瓦斯引燃引爆1.人井人员必须随身携带自救器、标识卡和矿灯，严禁携带烟草和点火物品，严禁穿化纤衣服。井下严禁使用灯泡取暖和使用电炉。井下和井口房内不得进行电焊、气焊和喷灯焊接作业。如果必须在井下主要硐室、主要进风井巷和井口房内行电焊、气焊和喷灯焊接工作，每次必须制定安全措施，由矿长批准并遵守《煤矿安全规程》（2 0 1 6年版）相关规定。2.加强放炮和火工品管理。炮眼封泥必须使用水炮泥。炮眼深度和炮眼的封泥长度应当符合《煤矿安全规程》（2 0 1 6年版）相关规定。采掘工作面，使用煤矿许用毫秒延期雷管时，最后一段的延期时间不得超过1 3 0 ms。只有在放炮地点附近20m以内风流中瓦斯浓度低于1%时，才允许药放炮。3.井下防爆电气设备的运行、维护和修理，必须符合防爆性能的各项技术要求。4.防止机械摩擦火花引燃瓦斯。5.避免高速移的物质产生的静放电现象。",{"id":6,"name":31,"category":32,"favorite":33},"二建矿业工程实务","建筑工程",0]