[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-790-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":669},{"id":5,"name":6,"category":7,"favorite":8},790,"二建建筑工程实务","建筑工程",0,28,50,2588,[13,38,53,68,83,98,113,128,142,157,172,186,200,212,227,239,251,263,272,284,296,310,324,338,350,364,379,391,403,415,427,439,451,463,475,487,499,509,523,537,551,565,579,591,603,615,623,635,647,659],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1121427,2,"多选题","护栏、扶手玻璃的技术要求（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","承受水平荷载栏板玻璃应使用公称厚度不小于16.76mm钢化夹层玻璃",true,{"key":24,"text":25,"correct":22},"B","当护栏玻璃最低点离一侧距楼地面高度大于5m时，不得使用承受水平荷载的栏板玻璃",{"key":27,"text":28,"correct":29},"C","当护栏玻璃最低点离一侧距楼地面高度在3m或3m以下，可以使用公称厚度不小于12mm普通玻璃",false,{"key":31,"text":32,"correct":22},"D","护栏和扶手制作与安装应采用坚固、耐久材料，并能承受规范允许的水平荷载",{"key":34,"text":35,"correct":22},"E","栏和扶手安装必须牢固","ABDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1121428,"吊顶工程按施工工艺和采用材料的不同分为（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"暗龙骨吊顶",{"key":24,"text":45,"correct":22},"明龙骨吊顶",{"key":27,"text":47,"correct":29},"木龙骨吊顶",{"key":31,"text":49,"correct":29},"平面吊顶",{"key":34,"text":51,"correct":29},"造型吊顶","AB",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1121429,"明龙骨吊顶饰面板的安装方法有（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"搁置法",{"key":24,"text":60,"correct":22},"嵌入法",{"key":27,"text":62,"correct":22},"卡固法",{"key":31,"text":64,"correct":29},"钉固法",{"key":34,"text":66,"correct":29},"粘贴法","ABC",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1121430,"轻质隔墙特点是（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":22},"自重轻",{"key":24,"text":75,"correct":22},"墙身薄",{"key":27,"text":77,"correct":22},"拆装方便",{"key":31,"text":79,"correct":22},"节能环保",{"key":34,"text":81,"correct":29},"防开裂","ABCD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},1121431,"接触（ ）的龙骨、埋置的木楔和金属型材应作防腐处理。",[87,89,91,93,95],{"key":20,"text":88,"correct":29},"塑料",{"key":24,"text":90,"correct":22},"石",{"key":27,"text":92,"correct":22},"混凝土",{"key":31,"text":94,"correct":29},"钢铁",{"key":34,"text":96,"correct":22},"砖","BCE",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":112,"analysis":37},1121432,"活动隔墙安装按固定方式不同分为（ ）固定方式。",[102,104,106,108,110],{"key":20,"text":103,"correct":22},"悬吊导向",{"key":24,"text":105,"correct":29},"推拉导向",{"key":27,"text":107,"correct":22},"支承导向",{"key":31,"text":109,"correct":29},"平开导向",{"key":34,"text":111,"correct":29},"旋转导向","AC",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":127,"analysis":37},1121433,"建筑地面工程施工时，铺设材料温度的控制应符合下列要求（ ）。",[117,119,121,123,125],{"key":20,"text":118,"correct":22},"采用掺有水泥、石灰的拌合料铺设不应低于5℃",{"key":24,"text":120,"correct":22},"用石油沥青胶结料铺贴时，不应低于5℃",{"key":27,"text":122,"correct":22},"采用有机胶粘剂粘贴时，不宜低于10℃",{"key":31,"text":124,"correct":29},"采用砂、石材料铺设时，不应低于5℃",{"key":34,"text":126,"correct":22},"采用自流平、涂料铺设时，不应低于5℃，也不应高于30℃","ABCE",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":67,"analysis":37},1121434,"变形缝包括（ ）。",[132,134,136,138,140],{"key":20,"text":133,"correct":22},"沉降缝",{"key":24,"text":135,"correct":22},"伸缩缝",{"key":27,"text":137,"correct":22},"防震缝",{"key":31,"text":139,"correct":29},"温度缝",{"key":34,"text":141,"correct":29},"预留缝",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":156,"analysis":37},1121435,"（ ）等大面积水泥混凝土垫层应分区段浇筑。",[146,148,150,152,154],{"key":20,"text":147,"correct":22},"工业厂房",{"key":24,"text":149,"correct":22},"礼堂",{"key":27,"text":151,"correct":29},"客厅",{"key":31,"text":153,"correct":29},"卧室",{"key":34,"text":155,"correct":22},"门厅","ABE",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":171,"analysis":37},1121436,"水泥混凝土（ ）等与建筑物连接处应设缝处理。",[161,163,165,167,169],{"key":20,"text":162,"correct":22},"明沟",{"key":24,"text":164,"correct":29},"暗沟",{"key":27,"text":166,"correct":22},"散水",{"key":31,"text":168,"correct":29},"窗台",{"key":34,"text":170,"correct":22},"台阶","ACE",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":127,"analysis":37},1121437,"有防水要求的建筑地面工程，铺设前必须对（ ）进行密封处理。",[176,178,180,182,184],{"key":20,"text":177,"correct":22},"立管",{"key":24,"text":179,"correct":22},"套管",{"key":27,"text":181,"correct":22},"地漏",{"key":31,"text":183,"correct":29},"砖缝",{"key":34,"text":185,"correct":22},"楼板节点之间",{"id":187,"libraryId":5,"type":188,"typeLabel":189,"stem":190,"options":191,"answer":27,"analysis":37},1121438,1,"单选题","雨期基坑开挖，坡顶散水的宽度最小限值是( )m。",[192,194,196,198],{"key":20,"text":193,"correct":29},"0.8",{"key":24,"text":195,"correct":29},"1",{"key":27,"text":197,"correct":22},"1.5",{"key":31,"text":199,"correct":29},"1.6",{"id":201,"libraryId":5,"type":188,"typeLabel":189,"stem":202,"options":203,"answer":27,"analysis":37},1121439,"冬期施工混凝土配合比宜选择较小的配合比指标是( )。",[204,206,208,210],{"key":20,"text":205,"correct":29},"水灰比和坍落度",{"key":24,"text":207,"correct":29},"水灰比和外加剂掺量",{"key":27,"text":209,"correct":22},"水胶比和坍落度",{"key":31,"text":211,"correct":29},"水胶比和外加剂掺量",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":226,"analysis":37},1121440,"关于防水工程高温施工的说法，正确的有( )。",[216,218,220,222,224],{"key":20,"text":217,"correct":29},"防水材料应随用随配，配制好的混合料宜在3h内用完",{"key":24,"text":219,"correct":22},"大体积防水混凝土入模温度不应大于30℃",{"key":27,"text":221,"correct":22},"改性石油沥青密封材料施工环境气温不高于35℃",{"key":31,"text":223,"correct":22},"高聚物改性沥青防水卷材贮存环境最高气温不得超过45℃",{"key":34,"text":225,"correct":22},"自粘型卷材贮存叠放层数不应超过5层","BCDE",{"id":228,"libraryId":5,"type":188,"typeLabel":189,"stem":229,"options":230,"answer":27,"analysis":37},1121441,"关于涂装环境温度和相对湿度的说法正确的是( )。",[231,233,235,237],{"key":20,"text":232,"correct":29},"环境温度不宜高于50℃，相对湿度不应大于85%",{"key":24,"text":234,"correct":29},"环境温度不宜高于50℃，相对湿度不应大于95%",{"key":27,"text":236,"correct":22},"环境温度不宜高于38℃，相对湿度不应大于85%",{"key":31,"text":238,"correct":29},"环境温度不宜高于38℃，相对湿度不应大于95%",{"id":240,"libraryId":5,"type":188,"typeLabel":189,"stem":241,"options":242,"answer":27,"analysis":37},1121442,"高温天气施工，存放焊条的库房温度最大限值是( )℃。",[243,245,247,249],{"key":20,"text":244,"correct":29},"30",{"key":24,"text":246,"correct":29},"40",{"key":27,"text":248,"correct":22},"50",{"key":31,"text":250,"correct":29},"60",{"id":252,"libraryId":5,"type":188,"typeLabel":189,"stem":253,"options":254,"answer":24,"analysis":37},1121443,"雨期施工中，调整砌筑砂浆水灰比的最主要参数是( )。",[255,257,259,261],{"key":20,"text":256,"correct":29},"外加剂含水量",{"key":24,"text":258,"correct":22},"砂的含水量",{"key":27,"text":260,"correct":29},"掺和物含水量",{"key":31,"text":262,"correct":29},"石子的含水量",{"id":264,"libraryId":5,"type":188,"typeLabel":189,"stem":265,"options":266,"answer":24,"analysis":37},1121444,"雨期施工中，砌筑工程每天砌筑高度最大限值是( )m。",[267,268,270,271],{"key":20,"text":193,"correct":29},{"key":24,"text":269,"correct":22},"1.2",{"key":27,"text":197,"correct":29},{"key":31,"text":199,"correct":29},{"id":273,"libraryId":5,"type":188,"typeLabel":189,"stem":274,"options":275,"answer":31,"analysis":37},1121445,"某砌筑工程，冬期采用暖棚法施工，室内温度5℃，其养护时间是( )d。",[276,278,280,282],{"key":20,"text":277,"correct":29},"3",{"key":24,"text":279,"correct":29},"4",{"key":27,"text":281,"correct":29},"5",{"key":31,"text":283,"correct":22},"7",{"id":285,"libraryId":5,"type":188,"typeLabel":189,"stem":286,"options":287,"answer":31,"analysis":37},1121446,"冬期采用氯盐砂浆施工，墙体留置洞口距交接墙处不应小于( )mm。",[288,290,292,294],{"key":20,"text":289,"correct":29},"200",{"key":24,"text":291,"correct":29},"300",{"key":27,"text":293,"correct":29},"400",{"key":31,"text":295,"correct":22},"500",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":127,"analysis":37},1121447,"高温施工混凝土配合比调整的因素有( )。",[300,302,304,306,308],{"key":20,"text":301,"correct":22},"环境温度",{"key":24,"text":303,"correct":22},"湿度",{"key":27,"text":305,"correct":22},"风力",{"key":31,"text":307,"correct":29},"混凝土初凝时间",{"key":34,"text":309,"correct":22},"采取的温控措施",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":156,"analysis":37},1121448,"关于高温天气施工的说法，正确的有( )。",[314,316,318,320,322],{"key":20,"text":315,"correct":22},"混凝土坍落度不宜小于70mm",{"key":24,"text":317,"correct":22},"混凝土拌合物出机温度不宜大于30℃",{"key":27,"text":319,"correct":29},"普通混凝土浇筑入模温度不应高于38℃",{"key":31,"text":321,"correct":29},"涂饰工程施工现场环境温度不宜高于40℃",{"key":34,"text":323,"correct":22},"聚合物抹面胶浆拌合水温度不宜大于80℃，且不宜低于40℃",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":67,"analysis":37},1121449,"冬期施工，防水混凝土养护应采用( )等方法。",[328,330,332,334,336],{"key":20,"text":329,"correct":22},"蓄热法",{"key":24,"text":331,"correct":22},"暖棚法",{"key":27,"text":333,"correct":22},"掺化学外加剂法",{"key":31,"text":335,"correct":29},"电加热法",{"key":34,"text":337,"correct":29},"蒸汽直接加热法",{"id":339,"libraryId":5,"type":188,"typeLabel":189,"stem":340,"options":341,"answer":24,"analysis":37},1121450,"关于高温天气混凝土施工的说法，错误的是( )。",[342,344,346,348],{"key":20,"text":343,"correct":29},"入模温度宜低于35℃",{"key":24,"text":345,"correct":22},"宜在午间进行浇筑",{"key":27,"text":347,"correct":29},"应及时进行保湿养护",{"key":31,"text":349,"correct":29},"宜用白色涂装混凝土运输车",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":156,"analysis":37},1121451,"关于混凝土施工期间的测温项目与频次的说法，正确的有( )。",[354,356,358,360,362],{"key":20,"text":355,"correct":22},"室外气温测量最高、最低气温",{"key":24,"text":357,"correct":22},"环境温度每昼夜不少于4次",{"key":27,"text":359,"correct":29},"搅拌机棚温度每一工作班不少于3次",{"key":31,"text":361,"correct":29},"外加剂溶液温度每一工作班不少于2次",{"key":34,"text":363,"correct":22},"混凝土出机、浇筑、入模温度每一工作班不少于4次",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":378,"analysis":37},1121452,"关于普通碳素结构钢、低合金钢工作地点温度控制的说法，正确的有( )。",[368,370,372,374,376],{"key":20,"text":369,"correct":29},"普通碳素结构钢工作地点温度低于-25℃，不得剪切、冲孔",{"key":24,"text":371,"correct":29},"低合金钢工作地点温度低于-20℃时不得剪切、冲孔",{"key":27,"text":373,"correct":29},"普通碳素结构钢工作地点温度低于-18℃，不得进行冷矫正和冷弯曲",{"key":31,"text":375,"correct":22},"低合金结构钢工作地点温度低于-12℃时不得进行冷矫正和冷弯曲",{"key":34,"text":377,"correct":22},"工作地点温度低于-30℃时，不宜进行现场火焰切割作业","DE",{"id":380,"libraryId":5,"type":188,"typeLabel":189,"stem":381,"options":382,"answer":27,"analysis":37},1121453,"混凝土工程冬期施工采用蒸汽养护时，应优先选用( )。",[383,385,387,389],{"key":20,"text":384,"correct":29},"硅酸盐水泥",{"key":24,"text":386,"correct":29},"普通硅酸盐水泥",{"key":27,"text":388,"correct":22},"矿渣硅酸盐水泥",{"key":31,"text":390,"correct":29},"复合水泥",{"id":392,"libraryId":5,"type":188,"typeLabel":189,"stem":393,"options":394,"answer":20,"analysis":37},1121454,"建筑外墙外保温工程冬期施工最低温度不应低于( )。",[395,397,399,401],{"key":20,"text":396,"correct":22},"-5℃",{"key":24,"text":398,"correct":29},"0℃",{"key":27,"text":400,"correct":29},"5℃",{"key":31,"text":402,"correct":29},"10℃",{"id":404,"libraryId":5,"type":188,"typeLabel":189,"stem":405,"options":406,"answer":31,"analysis":37},1121455,"冬期施工混凝土搅拌时，当仅加热拌合水不能满足热工计算要求时，可直接加热的混凝土原材料是( )。",[407,409,411,413],{"key":20,"text":408,"correct":29},"水泥",{"key":24,"text":410,"correct":29},"外加剂",{"key":27,"text":412,"correct":29},"矿物掺合料",{"key":31,"text":414,"correct":22},"热骨料",{"id":416,"libraryId":5,"type":188,"typeLabel":189,"stem":417,"options":418,"answer":20,"analysis":37},1121456,"某防水工程，施工环境气温-8℃，应选择的防水材料是( )。",[419,421,423,425],{"key":20,"text":420,"correct":22},"高聚物改性沥青防水卷材",{"key":24,"text":422,"correct":29},"现喷硬泡聚氨酯",{"key":27,"text":424,"correct":29},"合成高分子防水涂料",{"key":31,"text":426,"correct":29},"改性石油沥青密封材料",{"id":428,"libraryId":5,"type":188,"typeLabel":189,"stem":429,"options":430,"answer":20,"analysis":37},1121457,"关于钢结构焊接加固的说法，正确的是( )。",[431,433,435,437],{"key":20,"text":432,"correct":22},"由对应类别合格的焊工施焊",{"key":24,"text":434,"correct":29},"施焊镇静钢板的厚度不大于30mm时，环境空气温度不应低于-20℃",{"key":27,"text":436,"correct":29},"施焊镇静钢板的厚度超过30mm时，温度不应低于-5℃",{"key":31,"text":438,"correct":29},"当施焊沸腾钢板时，环境空气温度应高于10℃",{"id":440,"libraryId":5,"type":188,"typeLabel":189,"stem":441,"options":442,"answer":31,"analysis":37},1121458,"关于建筑装饰装修工程高温施工环境温度控制的说法，正确的是( )。",[443,445,447,449],{"key":20,"text":444,"correct":29},"塑料门窗储存的环境温度应低于60℃",{"key":24,"text":446,"correct":29},"抹灰环境温度不宜高于50℃",{"key":27,"text":448,"correct":29},"粘贴饰面砖环境温度不宜高于45℃",{"key":31,"text":450,"correct":22},"涂饰工程施工现场环境温度不宜高于35℃",{"id":452,"libraryId":5,"type":188,"typeLabel":189,"stem":453,"options":454,"answer":24,"analysis":37},1121459,"关于冬期建筑装饰装修工程施工的说法，正确的是( )。",[455,457,459,461],{"key":20,"text":456,"correct":29},"室内抹灰，块料装饰工程施工与养护期间的温度不应低于0℃",{"key":24,"text":458,"correct":22},"油漆、刷浆、裱糊、玻璃工程，室外施工时，其最低环境温度不应低于5℃",{"key":27,"text":460,"correct":29},"室外喷、涂，刷油漆、高级涂料时，料浆使用温度宜保持5℃左右",{"key":31,"text":462,"correct":29},"塑料门窗当在不大于0℃的环境中存放时，与热源的距离不应小于0.5m",{"id":464,"libraryId":5,"type":188,"typeLabel":189,"stem":465,"options":466,"answer":31,"analysis":37},1121460,"高温施工混凝土配合比设计的原则是( )用量。",[467,469,471,473],{"key":20,"text":468,"correct":29},"低粗骨料",{"key":24,"text":470,"correct":29},"高拌合水",{"key":27,"text":472,"correct":29},"高细骨料",{"key":31,"text":474,"correct":22},"低水泥",{"id":476,"libraryId":5,"type":188,"typeLabel":189,"stem":477,"options":478,"answer":27,"analysis":37},1121461,"雨期CFG桩施工，槽底预留的保护层厚度最小限值是( )m。",[479,481,483,485],{"key":20,"text":480,"correct":29},"0.2",{"key":24,"text":482,"correct":29},"0.3",{"key":27,"text":484,"correct":22},"0.5",{"key":31,"text":486,"correct":29},"0.7",{"id":488,"libraryId":5,"type":188,"typeLabel":189,"stem":489,"options":490,"answer":20,"analysis":37},1121462,"室外的基坑可采用含有冻土块的土回填，冻土块粒径不得大于( )mm，含量不得超过( )，且应均匀分布。",[491,493,495,497],{"key":20,"text":492,"correct":22},"150;15%",{"key":24,"text":494,"correct":29},"150;30%",{"key":27,"text":496,"correct":29},"100:15%",{"key":31,"text":498,"correct":29},"100;30%",{"id":500,"libraryId":5,"type":188,"typeLabel":189,"stem":501,"options":502,"answer":20,"analysis":37},1121463,"冬期施工砌体采用氯盐砂浆施工,每日砌筑高度不宜超过( )m。",[503,504,506,507],{"key":20,"text":269,"correct":22},{"key":24,"text":505,"correct":29},"1.4",{"key":27,"text":197,"correct":29},{"key":31,"text":508,"correct":29},"1.8",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":67,"analysis":37},1121464,"关于冬期施工冻土回填的说法，正确的有( )。",[513,515,517,519,521],{"key":20,"text":514,"correct":22},"室外的基槽（坑）或管沟可采用含有冻土块的土回填",{"key":24,"text":516,"correct":22},"填方边坡的表层1m以内，不得采用含有冻土块的土填筑",{"key":27,"text":518,"correct":22},"室外管沟底以上500mm的范围内不得用含有冻土块的土回填",{"key":31,"text":520,"correct":29},"室内的基槽（坑）或管沟可采用含有冻土块的土回填",{"key":34,"text":522,"correct":29},"室内地面垫层下回填的土方，填料中可含有冻土块",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":127,"analysis":37},1121465,"关于冬期施工砌体工程的说法，正确的有( )。",[527,529,531,533,535],{"key":20,"text":528,"correct":22},"应编制冬期施工专项方案",{"key":24,"text":530,"correct":22},"不得使用遭水浸和受冻后表面结冰、污染的砖或砌块",{"key":27,"text":532,"correct":22},"砌筑砂浆宜采用普通硅酸盐水泥配制，不得使用无水泥拌制的砂浆",{"key":31,"text":534,"correct":29},"最低气温等于或低于-25℃时，砌体砂浆强度等级应较常温施工提高一级",{"key":34,"text":536,"correct":22},"暖棚法施工时，暖棚内的最低温度不应低干5℃",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":82,"analysis":37},1121466,"冬期施工不得采用掺氯盐砂浆砌筑的砌体有( )。",[541,543,545,547,549],{"key":20,"text":542,"correct":22},"对装饰工程有特殊要求的建筑物",{"key":24,"text":544,"correct":22},"配筋、钢埋件无可靠防腐处理措施的砌体",{"key":27,"text":546,"correct":22},"接近高压电线的建筑物（如变电所、发电站等）",{"key":31,"text":548,"correct":22},"经常处于地下水位变化范围内的结构",{"key":34,"text":550,"correct":29},"地下已设防水层的结构",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":36,"analysis":37},1121467,"关于砌体工程雨期施工的说法，正确的有( )。",[555,557,559,561,563],{"key":20,"text":556,"correct":22},"烧结类块体的相对含水率60%～70%",{"key":24,"text":558,"correct":22},"每天砌筑高度不得超过1.2m",{"key":27,"text":560,"correct":29},"根据石子的含水量变化随时调整水灰比",{"key":31,"text":562,"correct":22},"湿拌砂浆根据气候条件采取遮阳、保温、防雨雪等措施",{"key":34,"text":564,"correct":22},"蒸压加气混凝土砌块的相对含水率40%～50%",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":67,"analysis":37},1121468,"关于混凝土工程雨期施工的说法，正确的有( )。",[569,571,573,575,577],{"key":20,"text":570,"correct":22},"对粗、细骨料含水率实时监测，及时调整混凝土配合比",{"key":24,"text":572,"correct":22},"选用具有防雨水冲刷性能的模板脱模剂",{"key":27,"text":574,"correct":22},"雨后应检查地基面的沉降，并应对模板及支架进行检查",{"key":31,"text":576,"correct":29},"大雨、暴雨天气不宜进行混凝土露天浇筑。",{"key":34,"text":578,"correct":29},"梁板同时浇筑时应沿主梁方向浇筑",{"id":580,"libraryId":5,"type":188,"typeLabel":189,"stem":581,"options":582,"answer":20,"analysis":37},1121469,"冬期土方回填每层铺土厚度应比常温施工时减少( )。",[583,585,587,589],{"key":20,"text":584,"correct":22},"20%～25%",{"key":24,"text":586,"correct":29},"25%～30%",{"key":27,"text":588,"correct":29},"30%～35%",{"key":31,"text":590,"correct":29},"35%～40%",{"id":592,"libraryId":5,"type":188,"typeLabel":189,"stem":593,"options":594,"answer":31,"analysis":37},1121470,"冬期砂浆拌合水温、砂加热温度不宜超过( )℃。",[595,597,599,601],{"key":20,"text":596,"correct":29},"90，50",{"key":24,"text":598,"correct":29},"90，40",{"key":27,"text":600,"correct":29},"80，50",{"key":31,"text":602,"correct":22},"80，40",{"id":604,"libraryId":5,"type":188,"typeLabel":189,"stem":605,"options":606,"answer":27,"analysis":37},1121471,"冬期预应力钢筋张拉环境温度控制的最小限值是( )℃。",[607,609,611,613],{"key":20,"text":608,"correct":29},"-30",{"key":24,"text":610,"correct":29},"-20",{"key":27,"text":612,"correct":22},"-15",{"key":31,"text":614,"correct":29},"-5",{"id":616,"libraryId":5,"type":188,"typeLabel":189,"stem":617,"options":618,"answer":24,"analysis":37},1121472,"HRB335、HRB400钢筋冬期冷弯加工环境温度控制的最小限值是( )℃。",[619,620,621,622],{"key":20,"text":608,"correct":29},{"key":24,"text":610,"correct":22},{"key":27,"text":612,"correct":29},{"key":31,"text":614,"correct":29},{"id":624,"libraryId":5,"type":188,"typeLabel":189,"stem":625,"options":626,"answer":20,"analysis":37},1121473,"关于混凝土拌合物出机温度、入模温度最小限值的说法，正确的是( )℃。",[627,629,631,633],{"key":20,"text":628,"correct":22},"10，5",{"key":24,"text":630,"correct":29},"10，10",{"key":27,"text":632,"correct":29},"20，5",{"key":31,"text":634,"correct":29},"20，10",{"id":636,"libraryId":5,"type":188,"typeLabel":189,"stem":637,"options":638,"answer":27,"analysis":37},1121474,"雨期钢结构工程施工，焊接作业区的相对湿度最大限值是( )%。",[639,641,643,645],{"key":20,"text":640,"correct":29},"70",{"key":24,"text":642,"correct":29},"85",{"key":27,"text":644,"correct":22},"90",{"key":31,"text":646,"correct":29},"95",{"id":648,"libraryId":5,"type":188,"typeLabel":189,"stem":649,"options":650,"answer":20,"analysis":37},1121475,"关于混凝土或抹灰基层雨期涂刷涂料的基层含水率说法，正确的有( )。",[651,653,655,657],{"key":20,"text":652,"correct":22},"溶剂型不得大于8%;水性涂料不得大于10%;木质基层不得大于12%",{"key":24,"text":654,"correct":29},"溶剂型不得大于8%；水性涂料不得大于12%;木质基层不得大于10%",{"key":27,"text":656,"correct":29},"溶剂型不得大于10%;水性涂料不得大于10%;木质基层不得大于12%",{"key":31,"text":658,"correct":29},"溶剂型不得大于10%;水性涂料不得大于12%；木质基层不得大于10%",{"id":660,"libraryId":5,"type":188,"typeLabel":189,"stem":661,"options":662,"answer":20,"analysis":37},1121476,"施工期间最高气温超过30℃时，现场拌制砂浆使用完毕时间是( )h内。",[663,665,667,668],{"key":20,"text":664,"correct":22},"2",{"key":24,"text":666,"correct":29},"2.5",{"key":27,"text":277,"correct":29},{"key":31,"text":279,"correct":29},[670,673,676,679,682,685],{"id":188,"name":671,"category":7,"favorite":672},"领导干部任职前廉政法规知识测试题",92,{"id":674,"name":675,"category":7,"favorite":188},595,"建筑结构与设备",{"id":677,"name":678,"category":7,"favorite":188},715,"招标采购专业知识与法律法规",{"id":680,"name":681,"category":7,"favorite":188},848,"市政方向-通用基础",{"id":683,"name":684,"category":7,"favorite":8},534,"BIM工程师",{"id":686,"name":684,"category":7,"favorite":8},535]