[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-790-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":656},{"id":5,"name":6,"category":7,"favorite":8},790,"二建建筑工程实务","建筑工程",0,27,50,2588,[13,34,46,58,70,82,94,106,118,130,142,153,165,177,189,207,221,236,251,266,281,296,311,326,340,352,364,376,388,400,412,422,434,446,457,469,481,490,500,511,522,531,543,558,571,584,598,612,627,642],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1121377,1,"单选题","下列关于吊顶工程施工说法错误的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","吊顶工程的钢筋吊杆应进行防锈处理",false,{"key":24,"text":25,"correct":22},"B","当吊杆长度大于1.5m时，应设置反支撑",{"key":27,"text":28,"correct":22},"C","主龙骨接长应采取对接，相邻接头应错开",{"key":30,"text":31,"correct":32},"D","重型设备应安装在龙骨上",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1121378,"饰面板（砖）工程中不须进行复验的项目是（ ）",[38,40,42,44],{"key":20,"text":39,"correct":22},"外墙陶瓷面砖的吸水率",{"key":24,"text":41,"correct":32},"室内用大理石的放射性",{"key":27,"text":43,"correct":22},"水泥基粘结料的粘结强度",{"key":30,"text":45,"correct":22},"寒冷地区外墙陶瓷的抗冻性",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1121379,"整体面层施工后,养护时间不应小于（ ）天。",[50,52,54,56],{"key":20,"text":51,"correct":32},"7",{"key":24,"text":53,"correct":22},"14",{"key":27,"text":55,"correct":22},"21",{"key":30,"text":57,"correct":22},"28",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1121380,"关于建筑幕墙防雷构造要求的说法，正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"幕墙的铝合金立柱在不小于10m范围内采用柔性导线连通上、下柱",{"key":24,"text":65,"correct":32},"幕墙立柱预埋件用圆钢或扁钢与主体结构的均压环焊接连通",{"key":27,"text":67,"correct":22},"防雷连接的钢构件在完成后不需进行防锈油漆涂刷",{"key":30,"text":69,"correct":22},"在有镀膜层的构件上进行防雷连接应保护好所有的镀膜层",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},1121381,"关于玻璃幕墙的说话，正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"防火层可以与幕墙玻璃直接接触",{"key":24,"text":77,"correct":22},"同一玻璃幕墙单元可以跨越两个防火分区",{"key":27,"text":79,"correct":32},"幕墙的金属框架应与主体结构的防雷体系可靠连接",{"key":30,"text":81,"correct":22},"防火层承托板可以采用铝板",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},1121382,"金属门窗及塑料门窗应采用（ ）的方法安装。",[86,88,90,92],{"key":20,"text":87,"correct":22},"立口法",{"key":24,"text":89,"correct":22},"边安装边砌口",{"key":27,"text":91,"correct":22},"先安装后砌口",{"key":30,"text":93,"correct":32},"预留洞口",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1121383,"上人的吊杆，可以采用（ ）的吊杆。",[98,100,102,104],{"key":20,"text":99,"correct":22},"Φ6",{"key":24,"text":101,"correct":32},"Φ8",{"key":27,"text":103,"correct":22},"Φ10",{"key":30,"text":105,"correct":22},"Φ12",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1121384,"幕墙外表面的检查、清洗作业不得在（ ）级以上风力和大雨（雪）天气下进行。",[110,112,114,116],{"key":20,"text":111,"correct":22},"3",{"key":24,"text":113,"correct":32},"4",{"key":27,"text":115,"correct":22},"5",{"key":30,"text":117,"correct":22},"6",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},1121385,"下列关于隔墙工程施工技术的说法，正确的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"在抗震设防地区，条板隔墙安装长度超过6米时，应设计圈梁加固",{"key":24,"text":125,"correct":22},"骨架隔墙中的石膏板不应采用自攻螺钉固定",{"key":27,"text":127,"correct":22},"玻璃板隔墙应使用磨砂玻璃",{"key":30,"text":129,"correct":32},"玻璃板隔墙应使用安全玻璃",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":30,"analysis":33},1121386,"新建筑物的混凝土或抹灰基层，涂饰涂料前应涂刷（ ）封闭底漆。",[134,136,138,140],{"key":20,"text":135,"correct":22},"防水",{"key":24,"text":137,"correct":22},"防腐",{"key":27,"text":139,"correct":22},"抗酸",{"key":30,"text":141,"correct":32},"抗碱",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1121387,"采用湿作业法施工的饰面板工程、石材进行背涂处理的目的是（ ）。",[146,148,150,151],{"key":20,"text":147,"correct":22},"防潮",{"key":24,"text":149,"correct":32},"防碱",{"key":27,"text":137,"correct":22},{"key":30,"text":152,"correct":22},"防酸",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":30,"analysis":33},1121388,"寒冷地区木门窗框与墙体间的空隙应填充（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"水泥砂浆",{"key":24,"text":160,"correct":22},"水泥混合砂浆",{"key":27,"text":162,"correct":22},"防腐材料",{"key":30,"text":164,"correct":32},"保温材料",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":20,"analysis":33},1121389,"符合平板形预埋件加工要求的是（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":32},"直锚筋与锚板应采用T形焊",{"key":24,"text":172,"correct":22},"当锚筋直径≤20mm时，宜采用穿孔塞焊",{"key":27,"text":174,"correct":22},"当锚筋直径>20mm时，宜采用压力埋弧焊",{"key":30,"text":176,"correct":22},"预埋件都应采取有效的防腐处理，当采用热镀锌防腐处理时，锌膜厚度应大于20μm",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},1121390,"水磨石面层厚度除有特殊要求外，宜为（ ）mm，且按石粒粒径确定。",[181,183,185,187],{"key":20,"text":182,"correct":22},"5～7",{"key":24,"text":184,"correct":32},"12～18",{"key":27,"text":186,"correct":22},"20",{"key":30,"text":188,"correct":22},"60",{"id":190,"libraryId":5,"type":191,"typeLabel":192,"stem":193,"options":194,"answer":206,"analysis":33},1121391,2,"多选题","幕墙面板安装和嵌缝的质量控制要点有（ ）。",[195,197,199,201,203],{"key":20,"text":196,"correct":32},"采用空缝设计的幕墙面板，必须有防水措施",{"key":24,"text":198,"correct":32},"硅酮耐候密封胶不宜在夜晚、雨天打胶",{"key":27,"text":200,"correct":32},"板块安装完成后，在嵌缝前应对槽壁和槽底进行清洁，密封胶与槽壁应两面黏结，不应三面黏结",{"key":30,"text":202,"correct":32},"玻璃、金属板和石材幕墙面板安装的固定点间距和紧固件的品种、质量都应符合设计和规范要求",{"key":204,"text":205,"correct":22},"E","明框玻璃幕墙嵌缝的橡胶条应按设计选用优质产品.其长度宜比框内槽口长2%～3%，并黏结牢固，镶嵌平整","ABCD",{"id":208,"libraryId":5,"type":191,"typeLabel":192,"stem":209,"options":210,"answer":206,"analysis":33},1121392,"建筑幕墙防火构造的要求包括（ ）。",[211,213,215,217,219],{"key":20,"text":212,"correct":32},"同一幕墙玻璃单元不应跨越两个防火分区",{"key":24,"text":214,"correct":32},"防火层不应与幕墙玻璃直接接触，防火材料朝玻璃面处宜采用装饰材料覆盖",{"key":27,"text":216,"correct":32},"当建筑设计要求防火分区分隔有通透效果时，可采用单片防火玻璃或由其加工成的中空、夹层防火玻璃",{"key":30,"text":218,"correct":32},"无窗槛墙的幕墙，应在每层楼板的外沿设置耐火极限不低于1.0h、高度不低于0.8m的不燃烧实体裙墙或防火玻璃墙",{"key":204,"text":220,"correct":22},"幕墙与各层楼板、隔墙外沿间的缝隙，应采用不燃材料或难燃材料封堵，填充材料可采用岩棉或矿棉，其厚度不应小于80mm",{"id":222,"libraryId":5,"type":191,"typeLabel":192,"stem":223,"options":224,"answer":235,"analysis":33},1121393,"建筑地面变形缝应按设计要求设置，并应符合（ ）等要求。",[225,227,229,231,233],{"key":20,"text":226,"correct":32},"沉降缝、伸缩缝应贯通建筑地面的各构造层",{"key":24,"text":228,"correct":32},"室内地面的水泥混凝土垫层，应设置纵向和横向伸缩缝",{"key":27,"text":230,"correct":22},"水泥混凝土垫层的平头缝缝间应设置隔离材料，浇筑时不得互相紧贴",{"key":30,"text":232,"correct":22},"毛地板铺设时，与墙之间不应留有缝隙",{"key":204,"text":234,"correct":32},"实木地板面层铺设时，面板与墙之间应留8～12mm缝隙","ABE",{"id":237,"libraryId":5,"type":191,"typeLabel":192,"stem":238,"options":239,"answer":250,"analysis":33},1121394,"下列墙面饰面砖粘贴工程的施工方法正确的有（ ）。",[240,242,244,246,248],{"key":20,"text":241,"correct":22},"水泥砂浆应满铺在饰面砖背面，一面墙一次粘贴到顶",{"key":24,"text":243,"correct":32},"粘贴前应进行放线定位和排砖，非整砖应排放在次要部位或阴角处",{"key":27,"text":245,"correct":32},"每面墙不宜有两列（行）以上非整砖，非整砖宽度不宜小于整砖的1／3",{"key":30,"text":247,"correct":32},"粘贴前应进行挑选，并浸水2h以上，晾干表面水分",{"key":204,"text":249,"correct":22},"在墙面突出物处，可用非整砖拼凑粘贴","BCD",{"id":252,"libraryId":5,"type":191,"typeLabel":192,"stem":253,"options":254,"answer":265,"analysis":33},1121395,"建筑幕墙防火构造的正确技术要求有（ ）。",[255,257,259,261,263],{"key":20,"text":256,"correct":32},"幕墙与各层楼板之间的水平防火带应采用岩棉或矿棉等材料填充，其厚度不应小于100mm",{"key":24,"text":258,"correct":22},"防火层应用厚度不小于1.0mm的镀锌钢板承托",{"key":27,"text":260,"correct":22},"防火层的填充材料应与玻璃紧密接触，不得留有缝隙",{"key":30,"text":262,"correct":32},"同一幕墙玻璃单元不应跨越两个防火区",{"key":204,"text":264,"correct":32},"无窗槛墙的幕墙，应在楼板外沿设置耐火极限不低于1.0h、高度不低于0.8m的不燃实体裙墙","ADE",{"id":267,"libraryId":5,"type":191,"typeLabel":192,"stem":268,"options":269,"answer":280,"analysis":33},1121396,"建筑地面工程施工时，下列关于环境温度及其所铺设材料温度的控制要求正确的是（ ）。",[270,272,274,276,278],{"key":20,"text":271,"correct":32},"采用砂、石材料铺设时，不应低于0℃",{"key":24,"text":273,"correct":22},"采用石灰拌合料铈设时，不应低于0℃",{"key":27,"text":275,"correct":32},"采用水泥拌合料铺设时，不应低于5℃",{"key":30,"text":277,"correct":32},"采用油沥青腔结料时，不应低于5℃",{"key":204,"text":279,"correct":32},"采用有机胶粘剂粘贴时，不宜低于10℃","ACDE",{"id":282,"libraryId":5,"type":191,"typeLabel":192,"stem":283,"options":284,"answer":295,"analysis":33},1121397,"下列关于地面工程施工方法，正确的是（ ）。",[285,287,289,291,293],{"key":20,"text":286,"correct":22},"建筑地面的沉降缝与结构的沉降缝应错开",{"key":24,"text":288,"correct":22},"木地板木龙骨应用沥青做防腐处理",{"key":27,"text":290,"correct":32},"木地板下面的木格栅与墙之间留20mm缝隙",{"key":30,"text":292,"correct":32},"实木地板铺设面板与墙之间留8-12mm缝隙",{"key":204,"text":294,"correct":32},"水泥混凝土散水明沟与建筑物连接处应设置沉降缝","CDE",{"id":297,"libraryId":5,"type":191,"typeLabel":192,"stem":298,"options":299,"answer":310,"analysis":33},1121398,"下列关于吊顶工程施工方法的叙述，正确的有（ ）。",[300,302,304,306,308],{"key":20,"text":301,"correct":32},"吊顶工程的木吊杆.木龙骨和木饰面板必须进行防火处理",{"key":24,"text":303,"correct":32},"吊顶工程中的预埋件.钢筋吊杆和型钢吊杆应进行防锈处理",{"key":27,"text":305,"correct":32},"吊顶灯具.风口及检修口等应设附加吊杆",{"key":30,"text":307,"correct":22},"主龙骨应吊挂在次龙骨上",{"key":204,"text":309,"correct":32},"安装面板前应完成吊顶内管道和设备的调试及验收","ABCE",{"id":312,"libraryId":5,"type":191,"typeLabel":192,"stem":313,"options":314,"answer":325,"analysis":33},1121399,"框支承玻璃幕墙的安装，立柱与主体结构连接采用螺栓连接时必须具有（ ）。",[315,317,319,321,323],{"key":20,"text":316,"correct":32},"一定的适应位移能力",{"key":24,"text":318,"correct":32},"可靠的防松措施",{"key":27,"text":320,"correct":22},"绝缘措施",{"key":30,"text":322,"correct":32},"防滑措施",{"key":204,"text":324,"correct":22},"防锈措施","ABD",{"id":327,"libraryId":5,"type":191,"typeLabel":192,"stem":328,"options":329,"answer":265,"analysis":33},1121400,"密封胶的施工不宜在（ ）打胶。",[330,332,334,336,338],{"key":20,"text":331,"correct":32},"夜晚",{"key":24,"text":333,"correct":22},"风天",{"key":27,"text":335,"correct":22},"白天",{"key":30,"text":337,"correct":32},"雪天",{"key":204,"text":339,"correct":32},"雨天",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":24,"analysis":33},1121401,"采用单层条板做分户墙时，其厚度不应小于（ ）。",[344,346,348,350],{"key":20,"text":345,"correct":22},"100mm",{"key":24,"text":347,"correct":32},"120mm",{"key":27,"text":349,"correct":22},"130mm",{"key":30,"text":351,"correct":22},"140mm",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":20,"analysis":33},1121402,"开槽长度不得大于隔墙长度的（ ）。",[356,358,360,362],{"key":20,"text":357,"correct":32},"1\u002F2",{"key":24,"text":359,"correct":22},"1\u002F3",{"key":27,"text":361,"correct":22},"1\u002F4",{"key":30,"text":363,"correct":22},"1\u002F5",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":24,"analysis":33},1121403,"条板隔墙上需要吊挂重物和设备时，不得单点固定，并应在设计时考虑加固措施，两点间距应大于（ ）mm。",[368,370,372,374],{"key":20,"text":369,"correct":22},"150",{"key":24,"text":371,"correct":32},"300",{"key":27,"text":373,"correct":22},"500",{"key":30,"text":375,"correct":22},"600",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":24,"analysis":33},1121404,"玻璃板隔墙框架安装后，将其槽口清理干净，垫好防振（ ）垫块，再安装玻璃。",[380,382,384,386],{"key":20,"text":381,"correct":22},"木材",{"key":24,"text":383,"correct":32},"橡胶",{"key":27,"text":385,"correct":22},"塑料",{"key":30,"text":387,"correct":22},"金属",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":20,"analysis":33},1121405,"建筑地面工程施工时，采用砂、石材料铺设时，铺设材料温度不应低于（ ）。",[392,394,396,398],{"key":20,"text":393,"correct":32},"0℃",{"key":24,"text":395,"correct":22},"5℃",{"key":27,"text":397,"correct":22},"10℃",{"key":30,"text":399,"correct":22},"15℃",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":27,"analysis":33},1121406,"水泥混凝土垫层的厚度不应小于（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":22},"20mm",{"key":24,"text":407,"correct":22},"40mm",{"key":27,"text":409,"correct":32},"60mm",{"key":30,"text":411,"correct":22},"80mm",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":24,"analysis":33},1121407,"水泥砂浆面层的厚度应符合设计要求，且不应小于（ ）。",[416,418,419,421],{"key":20,"text":417,"correct":22},"10mm",{"key":24,"text":405,"correct":32},{"key":27,"text":420,"correct":22},"30mm",{"key":30,"text":407,"correct":22},{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":27,"analysis":33},1121408,"室内地面的水泥混凝土垫层，纵向缩缝间距不得大于（ ）。",[426,428,430,432],{"key":20,"text":427,"correct":22},"2m",{"key":24,"text":429,"correct":22},"4m",{"key":27,"text":431,"correct":32},"6m",{"key":30,"text":433,"correct":22},"8m",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":27,"analysis":33},1121409,"厕浴间和有防水要求的建筑地面必须设置防水隔离层。楼层结构必须采用现浇混凝土或整块预制混凝土板，混凝土强度等级不应小于（ ）。",[438,440,442,444],{"key":20,"text":439,"correct":22},"C10",{"key":24,"text":441,"correct":22},"C15",{"key":27,"text":443,"correct":32},"C20",{"key":30,"text":445,"correct":22},"C25",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":27,"analysis":33},1121410,"楼板四周除门洞外应做混凝土翻边，高度不应小于（ ），宽同墙厚，混凝土强度等级不应小于C20。",[450,451,453,455],{"key":20,"text":345,"correct":22},{"key":24,"text":452,"correct":22},"150mm",{"key":27,"text":454,"correct":32},"200mm",{"key":30,"text":456,"correct":22},"250mm",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":30,"analysis":33},1121411,"不发火（防爆的）面层中的碎石不发生火性必须合格；砂应质地坚硬、表面粗糙，其粒径宜为0.15～5mm，含泥量不应大于（ ），有机物含量不应大于0.5%。",[461,463,465,467],{"key":20,"text":462,"correct":22},"1.5%",{"key":24,"text":464,"correct":22},"2%",{"key":27,"text":466,"correct":22},"2.5%",{"key":30,"text":468,"correct":32},"3%",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":20,"analysis":33},1121412,"凡是两种不同金属的接触面之间，除不锈钢外，都应加（ ），以防止产生双金属腐蚀。",[473,475,477,479],{"key":20,"text":474,"correct":32},"防腐隔离柔性垫片",{"key":24,"text":476,"correct":22},"弹簧垫片",{"key":27,"text":478,"correct":22},"不锈钢垫片",{"key":30,"text":480,"correct":22},"胶木垫片",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":33},1121413,"明框玻璃幕墙的玻璃面板安装时，构件框槽底部应设两块橡胶块，放置宽度与槽宽相同、长度不小于（ ），玻璃四周嵌入量及空隙应符合要求，左右空隙宜一致。",[485,487,488,489],{"key":20,"text":486,"correct":22},"50mm",{"key":24,"text":345,"correct":32},{"key":27,"text":452,"correct":22},{"key":30,"text":454,"correct":22},{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":27,"analysis":33},1121414,"玻璃幕墙开启窗的开启角度不宜大于30°，开启距离不宜大于（ ）。",[494,495,496,498],{"key":20,"text":345,"correct":22},{"key":24,"text":454,"correct":22},{"key":27,"text":497,"correct":32},"300mm",{"key":30,"text":499,"correct":22},"400mm",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":30,"analysis":33},1121415,"推拉门窗在门窗框安装固定后，推拉扇开关力应不大于（ ）N。",[504,506,507,509],{"key":20,"text":505,"correct":22},"40",{"key":24,"text":188,"correct":22},{"key":27,"text":508,"correct":22},"100",{"key":30,"text":510,"correct":32},"50",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":27,"analysis":33},1121416,"塑料门窗固定片之间的间距应符合设计要求，并不得大于（ ）。",[515,516,518,520],{"key":20,"text":499,"correct":22},{"key":24,"text":517,"correct":22},"500mm",{"key":27,"text":519,"correct":32},"600mm",{"key":30,"text":521,"correct":22},"700mm",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},1121417,"条板隔墙开槽应在隔墙安装（ ）d后进行。",[526,527,528,530],{"key":20,"text":115,"correct":22},{"key":24,"text":51,"correct":32},{"key":27,"text":529,"correct":22},"10",{"key":30,"text":53,"correct":22},{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":27,"analysis":33},1121418,"安装石材幕墙的石材面板时，石板与金属挂件之间应采用（ ） 粘结。",[535,537,539,541],{"key":20,"text":536,"correct":22},"硅酮结构密封胶",{"key":24,"text":538,"correct":22},"云石胶",{"key":27,"text":540,"correct":32},"环氧树脂胶粘剂",{"key":30,"text":542,"correct":22},"聚硫胶",{"id":544,"libraryId":5,"type":191,"typeLabel":192,"stem":545,"options":546,"answer":557,"analysis":33},1121419,"粘贴墙面砖表面质量应（ ）。",[547,549,551,553,555],{"key":20,"text":548,"correct":32},"平整",{"key":24,"text":550,"correct":32},"接缝平直",{"key":27,"text":552,"correct":32},"缝宽均匀一致",{"key":30,"text":554,"correct":22},"颜色一致",{"key":204,"text":556,"correct":22},"墙地砖对缝","ABC",{"id":559,"libraryId":5,"type":191,"typeLabel":192,"stem":560,"options":561,"answer":206,"analysis":33},1121420,"饰面板（砖）工程应对下列材料及其性能指标进行复验（ ）。",[562,564,566,567,569],{"key":20,"text":563,"correct":32},"室内用瓷质饰面砖的放射性",{"key":24,"text":565,"correct":32},"严寒及寒冷地区外墙 陶瓷饰面砖的拉伸粘结强度",{"key":27,"text":39,"correct":32},{"key":30,"text":568,"correct":32},"严寒及寒冷地区外墙陶瓷饰面砖的抗冻性",{"key":204,"text":570,"correct":22},"外墙陶瓷面砖的粘贴强度",{"id":572,"libraryId":5,"type":191,"typeLabel":192,"stem":573,"options":574,"answer":265,"analysis":33},1121421,"开启窗周边缝隙宜采用（ ）、制品密封。",[575,577,579,580,582],{"key":20,"text":576,"correct":32},"氯丁橡胶",{"key":24,"text":578,"correct":22},"结构胶",{"key":27,"text":538,"correct":22},{"key":30,"text":581,"correct":32},"三元乙丙橡胶",{"key":204,"text":583,"correct":32},"硅橡胶密封条",{"id":585,"libraryId":5,"type":191,"typeLabel":192,"stem":586,"options":587,"answer":235,"analysis":33},1121422,"密封胶嵌缝时，下面那些做法是正确的（ ）。",[588,590,592,594,596],{"key":20,"text":589,"correct":32},"嵌缝前应将板缝清洁干净",{"key":24,"text":591,"correct":32},"严禁使用过期的密封胶",{"key":27,"text":593,"correct":22},"硅酮结构密封胶宜作为硅酮耐候密封胶使用",{"key":30,"text":595,"correct":22},"同一个工程可以使用不同品牌的硅酮结构密封胶",{"key":204,"text":597,"correct":32},"同一个工程应使用同一品牌的硅酮耐候密封胶",{"id":599,"libraryId":5,"type":191,"typeLabel":192,"stem":600,"options":601,"answer":611,"analysis":33},1121423,"建筑幕墙防火构造要求正确的有（ ）。",[602,604,606,608,609],{"key":20,"text":603,"correct":22},"防火层应采用厚度不小于1.0mm的镀锌钢板承托",{"key":24,"text":605,"correct":32},"应采用岩棉或矿棉不燃材料填充封堵，其厚度不应小于100mm",{"key":27,"text":607,"correct":22},"承托板与主体结构、幕墙结构及承托板之间的缝隙应采用密封胶密封",{"key":30,"text":212,"correct":32},{"key":204,"text":610,"correct":32},"防火层不应与幕墙玻璃直接接触","BDE",{"id":613,"libraryId":5,"type":191,"typeLabel":192,"stem":614,"options":615,"answer":626,"analysis":33},1121424,"木门窗框安装正确的是（ ）。",[616,618,620,622,624],{"key":20,"text":617,"correct":32},"复查洞口标高、尺寸及木砖位置",{"key":24,"text":619,"correct":32},"将门窗框用木楔临时固定在门窗洞口内相应位置",{"key":27,"text":621,"correct":22},"用砸扁钉帽的钉子钉牢在木砖上，钉帽要冲入木框内2～3mm",{"key":30,"text":623,"correct":32},"木门窗框镶贴脸",{"key":204,"text":625,"correct":32},"木门窗与墙体间填嵌缝隙","ABDE",{"id":628,"libraryId":5,"type":191,"typeLabel":192,"stem":629,"options":630,"answer":641,"analysis":33},1121425,"当门窗与墙体固定时，固定方法错误的是（ ）。",[631,633,635,637,639],{"key":20,"text":632,"correct":22},"混凝土墙洞口采用射钉或膨胀螺钉固定",{"key":24,"text":634,"correct":32},"砖墙洞口应用射钉或膨胀螺钉固定，不得固定在砖缝处。",{"key":27,"text":636,"correct":32},"轻质砌块或加气混凝土洞口可用射钉或膨胀螺钉固定",{"key":30,"text":638,"correct":22},"设有预埋铁件的洞口应采用焊接的方法固定",{"key":204,"text":640,"correct":22},"窗下框与墙体也采用固定片固定","BC",{"id":643,"libraryId":5,"type":191,"typeLabel":192,"stem":644,"options":645,"answer":310,"analysis":33},1121426,"裱糊施工技术要求（ ）。",[646,648,650,652,654],{"key":20,"text":647,"correct":32},"裱糊前，应按壁纸、墙布的品种、花色、规格进行选配、拼花、裁切、编号，裱糊时应按编号顺序粘贴",{"key":24,"text":649,"correct":32},"裱糊使用的胶粘剂应按壁纸或墙布的品种选配，应具备防霉、耐久等性能",{"key":27,"text":651,"correct":32},"各幅拼接应横平竖直，拼接处花纹、图案应吻合，不离缝，不搭接，不显拼缝",{"key":30,"text":653,"correct":22},"裱糊时，阴阳角处应无接缝，应包角压实",{"key":204,"text":655,"correct":32},"壁纸、墙布应粘贴牢固，不得有漏贴补贴、脱层、空鼓和翘边",[657,660,663,666,669,672],{"id":15,"name":658,"category":7,"favorite":659},"领导干部任职前廉政法规知识测试题",92,{"id":661,"name":662,"category":7,"favorite":15},595,"建筑结构与设备",{"id":664,"name":665,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":667,"name":668,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":670,"name":671,"category":7,"favorite":8},534,"BIM工程师",{"id":673,"name":671,"category":7,"favorite":8},535]