[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1121425":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1121425,790,2,"多选题","当门窗与墙体固定时，固定方法错误的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","混凝土墙洞口采用射钉或膨胀螺钉固定",false,{"key":16,"text":17,"correct":18},"B","砖墙洞口应用射钉或膨胀螺钉固定，不得固定在砖缝处。",true,{"key":20,"text":21,"correct":18},"C","轻质砌块或加气混凝土洞口可用射钉或膨胀螺钉固定",{"key":23,"text":24,"correct":14},"D","设有预埋铁件的洞口应采用焊接的方法固定",{"key":26,"text":27,"correct":14},"E","窗下框与墙体也采用固定片固定","BC","2021\u002F2020版教材P113 “（2）门窗框固定： 当门窗与墙体固定时，应先固定上框，后固定边框。固定方法如下： 1）混凝土墙洞口采用射钉或膨胀螺钉固定； 2）砖墙洞口应用膨胀螺钉固定，不得固定在砖缝处，并严禁用射钉固定； 3）轻质砌块或加气混凝土洞口可在预埋混凝土块上用射钉或膨胀螺钉固定； 4）设有预埋铁件的洞口应采用焊接的方法固定，也可先在预埋件上按紧固件规格打基孔，然后用紧固件固定； 5）窗下框与墙体也采用固定片固定，但应按照设计要求，处理好室内窗台板与室外窗台的节点处理，防止窗台渗水。",{"id":6,"name":31,"category":32,"favorite":33},"二建建筑工程实务","建筑工程",0]