[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1121392":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1121392,790,2,"多选题","建筑幕墙防火构造的要求包括（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","同一幕墙玻璃单元不应跨越两个防火分区",true,{"key":16,"text":17,"correct":14},"B","防火层不应与幕墙玻璃直接接触，防火材料朝玻璃面处宜采用装饰材料覆盖",{"key":19,"text":20,"correct":14},"C","当建筑设计要求防火分区分隔有通透效果时，可采用单片防火玻璃或由其加工成的中空、夹层防火玻璃",{"key":22,"text":23,"correct":14},"D","无窗槛墙的幕墙，应在每层楼板的外沿设置耐火极限不低于1.0h、高度不低于0.8m的不燃烧实体裙墙或防火玻璃墙",{"key":25,"text":26,"correct":27},"E","幕墙与各层楼板、隔墙外沿间的缝隙，应采用不燃材料或难燃材料封堵，填充材料可采用岩棉或矿棉，其厚度不应小于80mm",false,"ABCD","2021\u002F2020版教材P120 七、建筑幕墙防火构造要求（1）幕墙与各层楼板、隔墙外沿的缝隙，应采用不燃材料或难燃材料封堵，填充材料可采用岩棉或矿棉，其厚度不应小于100mm",{"id":6,"name":31,"category":32,"favorite":33},"二建建筑工程实务","建筑工程",0]