[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1121389":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},1121389,790,1,"单选题","符合平板形预埋件加工要求的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","直锚筋与锚板应采用T形焊",true,{"key":16,"text":17,"correct":18},"B","当锚筋直径≤20mm时，宜采用穿孔塞焊",false,{"key":20,"text":21,"correct":18},"C","当锚筋直径>20mm时，宜采用压力埋弧焊",{"key":23,"text":24,"correct":18},"D","预埋件都应采取有效的防腐处理，当采用热镀锌防腐处理时，锌膜厚度应大于20μm","2021\u002F2020版教材P116 （一）预埋件制作的技术要求： （1）锚板宜采用Q235级钢，锚筋应采用HPB300、HRB335或HRB400级热轧钢筋，严禁使用冷加工钢筋。 （2）直锚筋与锚板应采用T形焊。当锚筋直径不大于20mm时，宜采用压力埋弧焊；当锚筋直径大于20mm时，宜采用穿孔塞焊。不允许把锚筋弯成∏形或L形与锚板焊接。当采用手工焊时，焊缝高度不宜小于6mm和0.5d（HPB235级钢筋）或0.6d（HRB335级、HRB400级钢筋），d为锚筋直径。 （3）预埋件都应采取有效的防腐处理，当采用热镀锌防腐处理时，锌膜厚度应大于40Um",{"id":6,"name":27,"category":28,"favorite":29},"二建建筑工程实务","建筑工程",0]