[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1121247":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1121247,790,2,"多选题","地下工程防水混凝土应连续浇筑，宜少留施工缝，当需要留设施工缝时其留置位置正确的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","墙体水平施工工缝应留在底板与侧墙的交接处",false,{"key":16,"text":17,"correct":14},"B","墙体有预留孔洞时，施工缝距孔洞边缘不宜大于300mm",{"key":19,"text":20,"correct":21},"C","顶板、底板不宜留施工缝",true,{"key":23,"text":24,"correct":21},"D","垂直施工缝宜于变形缝相结合",{"key":26,"text":27,"correct":14},"E","板墙结合的水平施工缝可留在板墙接缝处","CD","2021\u002F2020版教材P88 该题主要考察的是：施工缝留设要求，墙体水平施工缝不应留在剪力最大处或底板与侧墙的交接处，应留在高出底板表面不小于300mm的墙体上。拱（板）墙结合的水平施工缝，宜留在拱（板）墙接缝线以下 150-300mm处。墙体有预留孔洞时，施工缝距孔洞边缘不应小于300mm。垂直施工缝应避开地下水和裂隙水较多的地段，并宜与变形缝相结合。",{"id":6,"name":31,"category":32,"favorite":33},"二建建筑工程实务","建筑工程",0]