[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1120828":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1120828,790,2,"多选题","围护结构的保温节能设计应采取如下措施( )。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","公共建筑每个朝向的窗墙面积比≤0.70",true,{"key":16,"text":17,"correct":14},"B","窗框采用塑料构件或断桥处理",{"key":19,"text":20,"correct":14},"C","采用双层中空玻璃或双层玻璃窗",{"key":22,"text":23,"correct":14},"D","对结构转角或交角等处采取保温措施",{"key":25,"text":26,"correct":27},"E","公共建筑透明幕墙的窗墙面积比≤0.80",false,"ABCD","2021\u002F2020版教材P7 （二）围护结构保温层的设置：2.围护结构和地面的保温设计控制窗墙面积比，公共建筑每个朝向的窗（包括透明幕墙）墙面积比不大于0.70；提高窗框的保温性能，采用塑料构件或断桥处理；采用双层中空玻璃或双层玻璃窗；结构转角或交角，外墙中钢筋混凝土柱、圈梁、楼板等处是热桥；热桥部分的温度值如果低于室内的露点温度，会造成表面结露；应在热桥部位采取保温措施。",{"id":6,"name":31,"category":32,"favorite":33},"二建建筑工程实务","建筑工程",0]