[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-787-43":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":715},{"id":5,"name":6,"category":7,"favorite":8},787,"二建机电工程实务","建筑工程",0,43,50,2160,[13,38,53,68,82,97,112,124,136,151,166,178,192,207,222,237,252,267,281,295,308,323,338,352,367,382,396,410,422,436,450,465,480,494,507,521,535,549,564,578,586,595,604,618,632,646,660,673,687,701],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1114007,2,"多选题","可作为建筑物防雷的自然接地体有（）。2012",[19,23,26,29,33],{"key":20,"text":21,"correct":22},"A","电缆保护钢管",false,{"key":24,"text":25,"correct":22},"B","埋地敷设的金属管道",{"key":27,"text":28,"correct":22},"C","金属电缆桥架",{"key":30,"text":31,"correct":32},"D","混凝土桩基中的钢筋",true,{"key":34,"text":35,"correct":32},"E","建筑物底板内的钢筋","DE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1114008,"当不允许在钢结构上做接地线焊接时,一般采用（）做接地线跨接。2018",[42,44,46,48,50],{"key":20,"text":43,"correct":32},"扁钢",{"key":24,"text":45,"correct":22},"圆钢",{"key":27,"text":47,"correct":22},"铜排",{"key":30,"text":49,"correct":22},"铜杆",{"key":34,"text":51,"correct":32},"两端焊（压）铜接头的导线","AE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1114009,"关于照明配电箱的安装技术要求，正确的有（）。2016",[57,59,61,63,65],{"key":20,"text":58,"correct":32},"插座为单独回路时的插座数量不宜超过10个",{"key":24,"text":60,"correct":32},"零线和保护接地线应在汇流排上连接",{"key":27,"text":62,"correct":22},"配电箱内应标明用电回路的名称和功率",{"key":30,"text":64,"correct":32},"每个单相分支回路的灯具数量不宜超过25个",{"key":34,"text":66,"correct":22},"每个三相分支回路的电流不宜超过16A","ABD",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":67,"analysis":37},1114010,"下列室内配线施工中，属于镀锌钢管明配的工序有（）2014",[72,74,76,78,80],{"key":20,"text":73,"correct":32},"测量定位",{"key":24,"text":75,"correct":32},"支架安装",{"key":27,"text":77,"correct":22},"钢管预埋",{"key":30,"text":79,"correct":32},"钢管连接",{"key":34,"text":81,"correct":22},"管内穿线",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":96,"analysis":37},1114011,"建筑防雷接地装置有（）。2011",[86,88,90,92,94],{"key":20,"text":87,"correct":32},"人工接地体",{"key":24,"text":89,"correct":32},"自然接地体",{"key":27,"text":91,"correct":22},"避雷针",{"key":30,"text":93,"correct":22},"避雷带",{"key":34,"text":95,"correct":22},"避雷网","AB",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":111,"analysis":37},1114012,"水平埋设的金属接地体一般采用（）等。",[101,103,105,107,109],{"key":20,"text":102,"correct":22},"镀锌角钢",{"key":24,"text":104,"correct":22},"镀锌钢管",{"key":27,"text":106,"correct":32},"镀锌圆钢",{"key":30,"text":108,"correct":32},"镀锌扁钢",{"key":34,"text":110,"correct":22},"镀锌槽钢","CD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":123,"analysis":37},1114013,"建筑强电井内的接地支线通常采用（）。",[116,118,119,120,121],{"key":20,"text":117,"correct":32},"铜线",{"key":24,"text":47,"correct":32},{"key":27,"text":43,"correct":32},{"key":30,"text":49,"correct":22},{"key":34,"text":122,"correct":22},"角钢","ABC",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":123,"analysis":37},1114014,"防雷装置的引下线主要由明敷于建筑物表面由上而下的（）构成。 2010",[128,129,130,132,134],{"key":20,"text":45,"correct":32},{"key":24,"text":43,"correct":32},{"key":27,"text":131,"correct":32},"裸导线",{"key":30,"text":133,"correct":22},"线槽",{"key":34,"text":135,"correct":22},"钢管",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":150,"analysis":37},1114015,"下列工序，属于成套电气照明灯具的施工序有（）。2015",[140,142,144,146,148],{"key":20,"text":141,"correct":32},"灯具检查",{"key":24,"text":143,"correct":22},"灯具组装",{"key":27,"text":145,"correct":32},"灯具安装",{"key":30,"text":147,"correct":32},"灯具接线",{"key":34,"text":149,"correct":32},"灯具送电","ACDE",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":165,"analysis":37},1114016,"关于管道内导线敷设的要求，正确的有（ ）。2019",[155,157,159,161,163],{"key":20,"text":156,"correct":22},"导线在管内敷设可有一个接头",{"key":24,"text":158,"correct":32},"线路绝缘电阻不应小于0.5MΩ",{"key":27,"text":160,"correct":32},"管内导线的总数不应多于8 根",{"key":30,"text":162,"correct":32},"中性线的导线绝缘层为淡蓝色",{"key":34,"text":164,"correct":22},"同一回路导线应穿同一导管内","BCD",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":123,"analysis":37},1114017,"下列防雷接地的分项工程，属于接闪器的有（）。2017",[170,171,172,174,176],{"key":20,"text":91,"correct":32},{"key":24,"text":93,"correct":32},{"key":27,"text":173,"correct":32},"均压环",{"key":30,"text":175,"correct":22},"接地干线",{"key":34,"text":177,"correct":22},"引下线",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":165,"analysis":37},1114018,"（2020年真题）关于导管内穿线和槽盒布线的说法正确的与（ ）。",[182,184,186,188,190],{"key":20,"text":183,"correct":22},"同一交流回路导线可穿入不同金属导管内",{"key":24,"text":185,"correct":32},"不同电压等级的导线不能穿在同一导管内",{"key":27,"text":187,"correct":32},"导管内的导线接头应设置在专用的接线盒内",{"key":30,"text":189,"correct":32},"同一槽盒内不宜同时敷设绝缘导线和电缆",{"key":34,"text":191,"correct":22},"垂直安装的槽盒内导线敷设不用分段固定",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":206,"analysis":37},1114019,"下列装置，属于蒸气压缩式制冷机组成部分的有（）。2015",[196,198,200,202,204],{"key":20,"text":197,"correct":32},"蒸发器",{"key":24,"text":199,"correct":22},"发生器",{"key":27,"text":201,"correct":32},"膨胀阀",{"key":30,"text":203,"correct":32},"冷凝器",{"key":34,"text":205,"correct":22},"分水器","ACD",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":221,"analysis":37},1114020,"符合风管安装就位程序的是（）。",[211,213,215,217,219],{"key":20,"text":212,"correct":22},"先下层后上层",{"key":24,"text":214,"correct":32},"先上层后下层",{"key":27,"text":216,"correct":32},"先立管后水平管",{"key":30,"text":218,"correct":22},"先水平管后立管",{"key":34,"text":220,"correct":22},"先大管后小管","BC",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":236,"analysis":37},1114021,"洁净空调系统满足洁净室空气要求的有（）。2016",[226,228,230,232,234],{"key":20,"text":227,"correct":32},"空气洁净度",{"key":24,"text":229,"correct":22},"室内负压",{"key":27,"text":231,"correct":32},"噪声标准",{"key":30,"text":233,"correct":22},"气流速度",{"key":34,"text":235,"correct":32},"温度、湿度","ACE",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":251,"analysis":37},1114022,"关于通风与空调系统进行试运行与调试的说法，正确的有（）。2017",[241,243,245,247,249],{"key":20,"text":242,"correct":22},"设备单机试运转前进行口头安全技术交底",{"key":24,"text":244,"correct":32},"通风系统的联系试运行应不少于2h",{"key":27,"text":246,"correct":32},"空调系统带冷（热）源的连续运行运行应不少于8h",{"key":30,"text":248,"correct":32},"系统总风量实测值与设计风量的偏差允许值不应大于10%",{"key":34,"text":250,"correct":32},"空调冷（热）水总流量测试结果与设计流量的偏差不应大于10%","BCDE",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":266,"analysis":37},1114023,"下列洁净空调系统金属风管必须涂密封胶的位置有（）。2018",[256,258,260,262,264],{"key":20,"text":257,"correct":22},"法兰焊接处",{"key":24,"text":259,"correct":32},"咬口缝",{"key":27,"text":261,"correct":32},"翻边处",{"key":30,"text":263,"correct":22},"焊接缝",{"key":34,"text":265,"correct":32},"铆钉处","BCE",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":111,"analysis":37},1114024,"通风空调工程中，系统调试的主要内容包括（）。2011",[271,273,275,277,279],{"key":20,"text":272,"correct":22},"风管严密性试验",{"key":24,"text":274,"correct":22},"风管漏光试验",{"key":27,"text":276,"correct":32},"单机试运转",{"key":30,"text":278,"correct":32},"无生产负荷联合试运转及调试",{"key":34,"text":280,"correct":22},"风管漏风试验",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":221,"analysis":37},1114025,"通风空调柜形风管制作时，应设导流叶片的管件是（）。2010",[285,287,289,291,293],{"key":20,"text":286,"correct":22},"风机出口的变径管",{"key":24,"text":288,"correct":32},"内斜线弯头",{"key":27,"text":290,"correct":32},"内弧型弯头",{"key":30,"text":292,"correct":22},"消声器进风口",{"key":34,"text":294,"correct":22},"风机进口的变径管",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":251,"analysis":37},1114026,"风管制作安装完成后必须对风管的（）进行严密性检验。2012",[299,301,302,304,306],{"key":20,"text":300,"correct":22},"板材",{"key":24,"text":259,"correct":32},{"key":27,"text":303,"correct":32},"铆接孔",{"key":30,"text":305,"correct":32},"法兰翻边",{"key":34,"text":307,"correct":32},"管段接缝",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":322,"analysis":37},1114027,"防、排烟系统或输送温度高于70℃的空气或烟气，应采用（）。",[312,314,316,318,320],{"key":20,"text":313,"correct":22},"软聚氯乙烯板",{"key":24,"text":315,"correct":22},"耐酸橡胶板",{"key":27,"text":317,"correct":32},"耐热橡胶板",{"key":30,"text":319,"correct":32},"不燃的耐温材料",{"key":34,"text":321,"correct":32},"防火材料","CDE",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":337,"analysis":37},1114028,"通风与空调施工中，安装单位应承担的协调配合工作有（）2013",[327,329,331,333,335],{"key":20,"text":328,"correct":32},"向设备供应商提供设备到货时间",{"key":24,"text":330,"correct":22},"与装饰单位协调风口开设位置",{"key":27,"text":332,"correct":32},"向电气单位提供设备的电气参数",{"key":30,"text":334,"correct":22},"复核及整改土建施工完毕的预留孔洞尺寸",{"key":34,"text":336,"correct":22},"负责各机电专业管线综合布置的确定","AC",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":165,"analysis":37},1114029,"关于变风量空调系统非设计满负荷条件下联合调试的要求，正确的有（ ）。2019",[342,344,346,348,350],{"key":20,"text":343,"correct":22},"系统总风量实测值与设计风量的偏差不应大于10%",{"key":24,"text":345,"correct":32},"系统空气处理机组应能在设计参数范围内对风机实现变频调速",{"key":27,"text":347,"correct":32},"空气处理机组新风量实测值与设计新风量的允许偏差为0~+10%",{"key":30,"text":349,"correct":32},"空调冷（热）水系统、冷却水系统总流量与设计流量的偏差不应大于10%",{"key":34,"text":351,"correct":22},"各变风量末端装置的最大风量调试结果与设计风量的偏差不应大于-5%~+15%",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":366,"analysis":37},1114030,"（2020年真题）关于洁净室空调风管制作的说法，正确的有（ ）。",[356,358,360,362,364],{"key":20,"text":357,"correct":22},"洁净度为N1级至N5级按中压系统风管制作",{"key":24,"text":359,"correct":32},"空调管道清洗后立即安装的风管可以不封口",{"key":27,"text":361,"correct":22},"内表面清洗干净且检查合格的风管可不封口",{"key":30,"text":363,"correct":32},"镀锌钢板风管的镀锌层损坏时应做防腐处理",{"key":34,"text":365,"correct":32},"矩形风管长度为800mm时不得有纵向拼接缝","BDE",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":381,"analysis":37},1114031,"安全防范系统的入侵报警探测器安装后,应对探测器的（）进行检查。2012",[371,373,375,377,379],{"key":20,"text":372,"correct":32},"防拆报警功能",{"key":24,"text":374,"correct":32},"短路报警功能",{"key":27,"text":376,"correct":32},"电源线被剪断报警功能",{"key":30,"text":378,"correct":32},"信号线开路报警功能",{"key":34,"text":380,"correct":22},"传输速度低报警功能","ABCD",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":165,"analysis":37},1114032,"设备的质量检测重点应包括（）。",[386,388,390,392,394],{"key":20,"text":387,"correct":22},"外观质量",{"key":24,"text":389,"correct":32},"安全性",{"key":27,"text":391,"correct":32},"可靠性",{"key":30,"text":393,"correct":32},"电磁兼容性",{"key":34,"text":395,"correct":22},"接口方式",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":409,"analysis":37},1114033,"建筑智能化系统的关键在与解决各系统之间的（）问题。",[400,402,403,405,407],{"key":20,"text":401,"correct":22},"数据格式",{"key":24,"text":395,"correct":22},{"key":27,"text":404,"correct":32},"互联",{"key":30,"text":406,"correct":22},"通信协议",{"key":34,"text":408,"correct":32},"互操作性","CE",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":111,"analysis":37},1114034,"建筑设备监控系统可以通过（）共享其他系统的数据，实现各系统的交互。2010",[414,416,418,419,420],{"key":20,"text":415,"correct":22},"反馈装置",{"key":24,"text":417,"correct":22},"监控元件",{"key":27,"text":406,"correct":32},{"key":30,"text":395,"correct":32},{"key":34,"text":421,"correct":22},"检测工具",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":266,"analysis":37},1114035,"下列关于建筑智能化工程系统检测的说法,正确的有（）。2018",[426,428,430,432,434],{"key":20,"text":427,"correct":22},"施工单位应组织项目检测小组",{"key":24,"text":429,"correct":32},"项目检测小组应指定检测负责人",{"key":27,"text":431,"correct":32},"检测前应提交试运行记录",{"key":30,"text":433,"correct":22},"检测的一般项目有一项不合格,系统检测结论为不合格",{"key":34,"text":435,"correct":32},"被集成系统接口检测不合格,集成系统的检测结果也为不合格",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":266,"analysis":37},1114036,"建筑智能化监控设备中，电动阀门驱动器参数必须满足设计要求的有（）。2011",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"尺寸",{"key":24,"text":443,"correct":32},"行程",{"key":27,"text":445,"correct":32},"压力",{"key":30,"text":447,"correct":22},"重量",{"key":34,"text":449,"correct":32},"最大关紧力",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":464,"analysis":37},1114037,"消防工程验收时，施工单位应提交的资料有（）。2011",[454,456,458,460,462],{"key":20,"text":455,"correct":32},"竣工图",{"key":24,"text":457,"correct":32},"隐蔽工程记录",{"key":27,"text":459,"correct":22},"安全记录",{"key":30,"text":461,"correct":32},"设备开箱记录",{"key":34,"text":463,"correct":32},"验收记录","ABDE",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":479,"analysis":37},1114038,"发生火灾报警后，需消防联动控制的有（）2014",[469,471,473,475,477],{"key":20,"text":470,"correct":32},"防火卷帘门",{"key":24,"text":472,"correct":22},"火灾探测器",{"key":27,"text":474,"correct":22},"消火栓按钮",{"key":30,"text":476,"correct":32},"防排烟风机",{"key":34,"text":478,"correct":32},"电梯","ADE",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":123,"analysis":37},1114039,"建筑消防产品的验收资料应包括（）。2010",[484,486,488,490,492],{"key":20,"text":485,"correct":32},"合格证书",{"key":24,"text":487,"correct":32},"认证书",{"key":27,"text":489,"correct":32},"检测报告",{"key":30,"text":491,"correct":22},"开箱记录",{"key":34,"text":493,"correct":22},"调试记录",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":123,"analysis":37},1114040,"建筑消防设施的合格证明文件有（）。2012",[498,500,501,503,505],{"key":20,"text":499,"correct":32},"产品合格证",{"key":24,"text":487,"correct":32},{"key":27,"text":502,"correct":32},"检验报告",{"key":30,"text":504,"correct":22},"使用说明书",{"key":34,"text":506,"correct":22},"外壳防护等级证明",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":322,"analysis":37},1114041,"电梯井道内应设置永久性电气照明均要求有（）。",[511,513,515,517,519],{"key":20,"text":512,"correct":22},"照明电压采用20V电压",{"key":24,"text":514,"correct":22},"照度不得小于20Lx",{"key":27,"text":516,"correct":32},"井道最高点0.5m内装一盏灯",{"key":30,"text":518,"correct":32},"井道最低点内0.5m装一盏灯",{"key":34,"text":520,"correct":32},"中间灯间距不超过7m",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":381,"analysis":37},1114042,"比较各施工方案技术的先进性，应包括的内容有（）。2018",[525,527,529,531,533],{"key":20,"text":526,"correct":32},"技术水平",{"key":24,"text":528,"correct":32},"技术创新程度",{"key":27,"text":530,"correct":32},"技术效率",{"key":30,"text":532,"correct":32},"实施的安全性",{"key":34,"text":534,"correct":22},"实施的地域性",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":206,"analysis":37},1114043,"下列施工作业内容中，需要编制施工方案的有（）。2017",[539,541,543,545,547],{"key":20,"text":540,"correct":32},"大型设备吊装",{"key":24,"text":542,"correct":22},"支架制作安装",{"key":27,"text":544,"correct":32},"压力管道焊接",{"key":30,"text":546,"correct":32},"设备试运行",{"key":34,"text":548,"correct":22},"灯具安装接线",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":563,"analysis":37},1114044,"在工程项目施工中，施工机具的选择要求有（ ）。2017",[553,555,557,559,561],{"key":20,"text":554,"correct":32},"满足施工方案的需要",{"key":24,"text":556,"correct":32},"适合工程的具体特点",{"key":27,"text":558,"correct":32},"保证施工质量的要求",{"key":30,"text":560,"correct":22},"小型设备超负荷运转",{"key":34,"text":562,"correct":32},"兼顾市场拓展的需要","ABCE",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":236,"analysis":37},1114045,"国家安全生产监督机构规定的特种作业人员有（ ）。2018",[568,570,572,574,576],{"key":20,"text":569,"correct":32},"焊工",{"key":24,"text":571,"correct":22},"司炉工",{"key":27,"text":573,"correct":32},"电工",{"key":30,"text":575,"correct":22},"水处理工",{"key":34,"text":577,"correct":32},"起重工",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":580,"answer":563,"analysis":37},1114046,[581,582,583,584,585],{"key":20,"text":554,"correct":32},{"key":24,"text":556,"correct":32},{"key":27,"text":558,"correct":32},{"key":30,"text":560,"correct":22},{"key":34,"text":562,"correct":32},{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":563,"analysis":37},1114047,"在工程项目施工中，施工机具的选择要求有（）。2017",[590,591,592,593,594],{"key":20,"text":554,"correct":32},{"key":24,"text":556,"correct":32},{"key":27,"text":558,"correct":32},{"key":30,"text":560,"correct":22},{"key":34,"text":562,"correct":32},{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":236,"analysis":37},1114048,"国家安全生产监督机构规定的特种作业人员有（）。2018",[599,600,601,602,603],{"key":20,"text":569,"correct":32},{"key":24,"text":571,"correct":22},{"key":27,"text":573,"correct":32},{"key":30,"text":575,"correct":22},{"key":34,"text":577,"correct":32},{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":479,"analysis":37},1114049,"下列沟通协调内容中，属于施工资源配备协调的有（）。2017",[608,610,612,614,616],{"key":20,"text":609,"correct":32},"设备材料有序供应",{"key":24,"text":611,"correct":22},"专业管线综合布置",{"key":27,"text":613,"correct":22},"施工垃圾分类堆放",{"key":30,"text":615,"correct":32},"施工机具优化配置",{"key":34,"text":617,"correct":32},"工程资金合理分配",{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":150,"analysis":37},1114050,"工程项目索赔发生的原因中，属于不可抗力因素的有（）。2018",[622,624,626,628,630],{"key":20,"text":623,"correct":32},"台风",{"key":24,"text":625,"correct":22},"物价变化",{"key":27,"text":627,"correct":32},"地震",{"key":30,"text":629,"correct":32},"洪水",{"key":34,"text":631,"correct":32},"战争",{"id":633,"libraryId":5,"type":15,"typeLabel":16,"stem":634,"options":635,"answer":52,"analysis":37},1114051,"下列场容管理措施中，不符合要求的有（）。2018",[636,638,640,642,644],{"key":20,"text":637,"correct":32},"施工现场围挡的高度1.5m",{"key":24,"text":639,"correct":22},"施工现场地平整，有排水措施",{"key":27,"text":641,"correct":22},"施工地点和周围清洁整齐，做到随时清理，工完场清",{"key":30,"text":643,"correct":22},"严禁损坏污染成品、堵塞通道",{"key":34,"text":645,"correct":32},"在下风口设置紧急出口",{"id":647,"libraryId":5,"type":15,"typeLabel":16,"stem":648,"options":649,"answer":337,"analysis":37},1114052,"降低项目施工成本的组织措施有（）。2018",[650,652,654,656,658],{"key":20,"text":651,"correct":32},"将成本责任分解到各岗位",{"key":24,"text":653,"correct":22},"选择最佳施工方案",{"key":27,"text":655,"correct":32},"确定合理的工作流程",{"key":30,"text":657,"correct":22},"制定资金使用计划",{"key":34,"text":659,"correct":22},"采取必要的风险对策",{"id":661,"libraryId":5,"type":15,"typeLabel":16,"stem":662,"options":663,"answer":165,"analysis":37},1114053,"下列竣工技术资料中，属于施工记录资料的有（）。2018",[664,665,667,669,671],{"key":20,"text":455,"correct":22},{"key":24,"text":666,"correct":32},"图纸会审记录",{"key":27,"text":668,"correct":32},"质量事故处理报告及记录",{"key":30,"text":670,"correct":32},"隐蔽工程验收记录",{"key":34,"text":672,"correct":22},"单位工程质量验收记录",{"id":674,"libraryId":5,"type":15,"typeLabel":16,"stem":675,"options":676,"answer":206,"analysis":37},1114054,"关于工程竣工档案编制及移交的要求，正确的有（）。2017",[677,679,681,683,685],{"key":20,"text":678,"correct":32},"项目竣工档案一般不少于两套",{"key":24,"text":680,"correct":22},"档案资料原件由建设单位保管",{"key":27,"text":682,"correct":32},"应编制工程档案资料移交清单",{"key":30,"text":684,"correct":32},"双方应在应缴清单上签字盖章",{"key":34,"text":686,"correct":22},"档案资料移交清单需一式三份",{"id":688,"libraryId":5,"type":15,"typeLabel":16,"stem":689,"options":690,"answer":236,"analysis":37},1114055,"施工现场使用的计量器具，项目经理部必须设专（兼）职计量管理员进行跟踪管理，包括（）的计量器具。2013",[691,693,695,697,699],{"key":20,"text":692,"correct":32},"向外单位租用",{"key":24,"text":694,"correct":22},"法定计量检定机构",{"key":27,"text":696,"correct":32},"施工单位自有",{"key":30,"text":698,"correct":22},"有相应资质检测单位",{"key":34,"text":700,"correct":32},"由建设单位提供",{"id":702,"libraryId":5,"type":15,"typeLabel":16,"stem":703,"options":704,"answer":381,"analysis":37},1114056,"特种设备制造、安装、改造、重大维修过程中，监督检查的主要内容（）。2011",[705,707,709,711,713],{"key":20,"text":706,"correct":32},"核实涉及安全性能的项目是否符合安全技术规范要求",{"key":24,"text":708,"correct":32},"抽查受检单位质量管理体系运转情况",{"key":27,"text":710,"correct":32},"确认出厂技术资料",{"key":30,"text":712,"correct":32},"确认安装、改造、重大维修的有关技术资料",{"key":34,"text":714,"correct":22},"检查受检单位进度计划执行情况",[716,720,723,726,729,732],{"id":717,"name":718,"category":7,"favorite":719},1,"领导干部任职前廉政法规知识测试题",92,{"id":721,"name":722,"category":7,"favorite":717},595,"建筑结构与设备",{"id":724,"name":725,"category":7,"favorite":717},715,"招标采购专业知识与法律法规",{"id":727,"name":728,"category":7,"favorite":717},848,"市政方向-通用基础",{"id":730,"name":731,"category":7,"favorite":8},534,"BIM工程师",{"id":733,"name":731,"category":7,"favorite":8},535]