[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-787-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":620},{"id":5,"name":6,"category":7,"favorite":8},787,"二建机电工程实务","建筑工程",0,4,50,2160,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,394,406,418,430,442,454,466,478,490,502,514,524,536,548,560,572,584,596,608],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1111992,1,"单选题","普通耐火材料的耐火度为（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1400～1558℃",false,{"key":24,"text":25,"correct":26},"B","1580～1770℃",true,{"key":28,"text":29,"correct":22},"C","1770～1838℃",{"key":31,"text":32,"correct":22},"D","1838～2000℃","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1111993,"下列关于开关和插座安装技术要求中不符合规定的是（） A.相线应经开关控制",[38,40,42,44],{"key":20,"text":39,"correct":22},"单相两孔插座，面对插座的右孔或上孔与相线连接，左孔或下孔应与中性导体连接",{"key":24,"text":41,"correct":22},"保护接地导体（P",{"key":28,"text":43,"correct":26},"在插座之间可串联连接",{"key":31,"text":45,"correct":22},"相线与中性导体（N）不应利用插座本体的接线端子转接供电",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1111994,"下列关于母线槽的施工技术要求说法错误的是（）",[50,52,54,56],{"key":20,"text":51,"correct":22},"母线槽安装前，应测量每节母线槽的绝缘电阻值，且不应小于20MΩ",{"key":24,"text":53,"correct":26},"母线槽水平安装时，圆钢吊架直径不得小于8mm，吊架间距不应大于1m",{"key":28,"text":55,"correct":22},"多根母线槽并列水平或垂直敷设时，各相邻母线槽间应预留维护、检修距离",{"key":31,"text":57,"correct":22},"母线槽安装完毕后，应对穿越防火墙和楼板的孔洞进行防火封堵",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1111995,"接地干线搭接焊接的要求错误的是（）",[62,64,66,68],{"key":20,"text":63,"correct":26},"扁钢之间搭接为扁钢宽度的3倍，不少于双面施焊",{"key":24,"text":65,"correct":22},"圆钢之间的搭接为圆钢直径的6倍，双面施焊",{"key":28,"text":67,"correct":22},"圆钢与扁钢搭接为圆钢直径的6倍，双面施焊",{"key":31,"text":69,"correct":22},"扁钢与钢管之间，紧贴3\u002F4管外径表面，上下两侧施焊",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1111996,"下列设备中，不属于电气照明工程组成的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"管内穿线",{"key":24,"text":77,"correct":26},"电加热器",{"key":28,"text":79,"correct":22},"风扇安装",{"key":31,"text":81,"correct":22},"插座安装",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1111997,"开关柜、配电柜的施工程序为：开箱检查→二次搬运→基础框架制作安装→（ ）→试验调整→送电运行验收。",[86,88,90,92],{"key":20,"text":87,"correct":22},"柜体固定→二次线路连接→母线连接",{"key":24,"text":89,"correct":26},"柜体固定→母线连接→二次线路连接",{"key":28,"text":91,"correct":22},"二次线路连接→母线连接→柜体固定",{"key":31,"text":93,"correct":22},"母线连接→二次线路连接→柜体固定",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1111998,"母线槽施工中在母线槽安装完毕之后，应进行（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"交接试验",{"key":24,"text":101,"correct":26},"通电前绝缘测试",{"key":28,"text":103,"correct":22},"送电前检查",{"key":31,"text":105,"correct":22},"送电验收",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},1111999,"配电柜安装时，相互间接缝宽度应不大于（ ）mm。",[110,112,114,116],{"key":20,"text":111,"correct":22},"5",{"key":24,"text":113,"correct":22},"3",{"key":28,"text":115,"correct":26},"2",{"key":31,"text":117,"correct":22},"1",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},1112000,"电动机电流干燥法时，其电流大小宜控制在电机额定电流的（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"40%以内",{"key":24,"text":125,"correct":22},"50%以内",{"key":28,"text":127,"correct":26},"60%以内",{"key":31,"text":129,"correct":22},"70%以内",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1112001,"下列关于人工接地体的施工技术要求，不正确的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"接地体的连接应搭接焊接",{"key":24,"text":137,"correct":26},"接地体的顶部距地面不小于0.5m",{"key":28,"text":139,"correct":22},"垂直接地体的长度一般为2.5m",{"key":31,"text":141,"correct":22},"接地体连接完毕后，应测试接地电阻",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},1112002,"下列不属于变配电室组成的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"电气设备试验",{"key":24,"text":149,"correct":22},"电缆头制作",{"key":28,"text":151,"correct":22},"母线槽安装",{"key":31,"text":153,"correct":22},"电缆敷设",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},1112003,"在动力设备的施工程序中，“设备安装”的紧后工作是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"控制设备安装",{"key":24,"text":161,"correct":22},"电机干燥",{"key":28,"text":163,"correct":26},"电动机检查.接线",{"key":31,"text":165,"correct":22},"送电前的检查",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},1112004,"建筑室内配管配线中，管内穿导线的紧后工序是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"导线绑扎",{"key":24,"text":173,"correct":22},"放线断线",{"key":28,"text":175,"correct":26},"导线并头绝缘",{"key":31,"text":177,"correct":22},"线路检查",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},1112005,"接地支线沿建筑物墙壁水平敷设时，离地面距离宜为（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":26},"0.3m",{"key":24,"text":185,"correct":22},"0.5m",{"key":28,"text":187,"correct":22},"1.0m",{"key":31,"text":189,"correct":22},"1.3m",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":33},1112006,"一般板厚小于等于1.2mm 的金属板材采用咬口连接，下列不属于常用的咬口形式的是（）",[194,196,198,200],{"key":20,"text":195,"correct":22},"单咬口",{"key":24,"text":197,"correct":22},"联合角咬口",{"key":28,"text":199,"correct":26},"双咬口",{"key":31,"text":201,"correct":22},"按扣式咬口",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},1112007,"风管系统内管内负压为（ ）属于中压系统。",[206,208,210,212],{"key":20,"text":207,"correct":22},"-500Pa≤P\u003C-125Pa",{"key":24,"text":209,"correct":26},"-1000Pa≤P\u003C-500Pa",{"key":28,"text":211,"correct":22},"-2000Pa≤P\u003C-1000Pa",{"key":31,"text":213,"correct":22},"-1000Pa\u003Cp≤-500pa",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},1112008,"通风与空调工程的施工单位通过系统（ ）后，即可进入竣工验收。",[218,220,222,224],{"key":20,"text":219,"correct":22},"测试合格",{"key":24,"text":221,"correct":22},"设备单机试运转及调整",{"key":28,"text":223,"correct":26},"无生产负荷联合试运转与调试",{"key":31,"text":225,"correct":22},"综合效能测定及调整",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":33},1112009,"空调水管道系统绝热施工应在（ ）进行。",[230,232,234,236],{"key":20,"text":231,"correct":26},"空调水管路系统试压和防腐处理结束后",{"key":24,"text":233,"correct":22},"空调风管系统设备绝热之前",{"key":28,"text":235,"correct":22},"空调风管系统风管绝热之后",{"key":31,"text":237,"correct":22},"空调水管路系统试压之前",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},1112010,"换热器及密闭容器在连接管道前，应进行（ ）试验。",[242,244,246,248],{"key":20,"text":243,"correct":26},"水压",{"key":24,"text":245,"correct":22},"满水",{"key":28,"text":247,"correct":22},"气压",{"key":31,"text":249,"correct":22},"严密性",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":33},1112011,"矩形风管边长不大于（ ）mm时，不得有纵向接缝。",[254,256,258,260],{"key":20,"text":255,"correct":26},"800mm",{"key":24,"text":257,"correct":22},"1000mm",{"key":28,"text":259,"correct":22},"1500mm",{"key":31,"text":261,"correct":22},"1200mm",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":28,"analysis":33},1112012,"系统总风量实测值与设计风量的偏差允许值不应大于（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"12%",{"key":24,"text":269,"correct":22},"15%",{"key":28,"text":271,"correct":26},"10%",{"key":31,"text":273,"correct":22},"20%",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":28,"analysis":33},1112013,"风管、部件及空调设备绝热工程施工应在（ ）进行。",[278,280,282,284],{"key":20,"text":279,"correct":22},"空调水系统试验后",{"key":24,"text":281,"correct":22},"设备单机调试后",{"key":28,"text":283,"correct":26},"风管系统严密性试验后",{"key":31,"text":285,"correct":22},"风管系统严密性试验前",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":31,"analysis":33},1112014,"冷却塔安装应水平，同一冷却水系统多台冷却塔安装时，各台冷却塔的水面高度应一致，高度偏差不应大于（ ）mm。",[290,292,294,296],{"key":20,"text":291,"correct":22},"10",{"key":24,"text":293,"correct":22},"15",{"key":28,"text":295,"correct":22},"20",{"key":31,"text":297,"correct":26},"30",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":28,"analysis":33},1112015,"洁净空调风管系统其中洁净度等级为N7级的按（ ）系统的风管制作要求。",[302,304,306,308],{"key":20,"text":303,"correct":22},"无压",{"key":24,"text":305,"correct":22},"低压",{"key":28,"text":307,"correct":26},"中压",{"key":31,"text":309,"correct":22},"高压",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},1112016,"建筑监控系统与电梯进行接头通信前，必须先约定好（）",[314,316,318,320],{"key":20,"text":315,"correct":22},"线路电压",{"key":24,"text":317,"correct":26},"通信协议",{"key":28,"text":319,"correct":22},"通信速度",{"key":31,"text":321,"correct":22},"通信频率",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":28,"analysis":33},1112017,"下列关于建筑智能化系统，线缆施工的说法错误的是（）",[326,328,330,332],{"key":20,"text":327,"correct":22},"线缆敷设前，应做电气导通检查",{"key":24,"text":329,"correct":22},"线路敷设完毕后，应做电气导通检查",{"key":28,"text":331,"correct":26},"用兆欧表测量线缆绝缘电阻，电阻值不应小于1MΩ",{"key":31,"text":333,"correct":22},"信号线缆与电力电缆交叉敷设时，宜成直角",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":31,"analysis":33},1112018,"建筑智能化系统，系统检测前应提交资料不包括（）",[338,340,342,344],{"key":20,"text":339,"correct":22},"设备开箱检验记录",{"key":24,"text":341,"correct":22},"分项工程质量验收记录",{"key":28,"text":343,"correct":22},"试运行记录",{"key":31,"text":345,"correct":26},"子分部工程检测记录",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":33},1112019,"下列关于同轴线缆施工的说法错误的是（）",[350,352,354,356],{"key":20,"text":351,"correct":22},"同轴线缆的衰减性能应满足设计要求",{"key":24,"text":353,"correct":26},"同轴电缆只能有一个中间接头",{"key":28,"text":355,"correct":22},"同轴电缆的最小弯曲半径应大于其外径的15倍",{"key":31,"text":357,"correct":22},"电梯轿厢的视频同轴电缆应选用电梯专用电缆",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":28,"analysis":33},1112020,"建筑智能化集成系统验收文件中，不包括的文件是（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"应用软件文档",{"key":24,"text":365,"correct":22},"接口技术文件",{"key":28,"text":367,"correct":26},"防火墙配备文件",{"key":31,"text":369,"correct":22},"接口测试文件",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":28,"analysis":33},1112021,"下列不属于建筑智能化设备选择时考虑因素的是（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"产品的品牌和生产地",{"key":24,"text":377,"correct":22},"应用实践以及供货渠道和供货周期",{"key":28,"text":379,"correct":26},"产品的使用人员",{"key":31,"text":381,"correct":22},"产品的网络性能及标准化程度",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":33},1112022,"下列分项工程中不属于智能化集成系统所包括的是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"设备安装",{"key":24,"text":389,"correct":26},"线缆敷设",{"key":28,"text":391,"correct":22},"接口及系统调试",{"key":31,"text":393,"correct":22},"软件安装",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":31,"analysis":33},1112023,"有关卫星接收天线的安装内容不正确的是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"天线底座接地电阻应小于4Ω",{"key":24,"text":401,"correct":22},"天线调节机构灵活.连续",{"key":28,"text":403,"correct":22},"卫星接收天线安装在避雷装置保护范围内",{"key":31,"text":405,"correct":26},"放大器箱室内安装高度为1.5m",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":33},1112024,"建筑智能化工程中使用有特殊要求的产品，其接口技术文件应符合（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"施工要求",{"key":24,"text":413,"correct":26},"合同要求",{"key":28,"text":415,"correct":22},"设计要求",{"key":31,"text":417,"correct":22},"使用要求",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":24,"analysis":33},1112025,"下列关于防烟排烟系统施工要求说法错误的是（）",[422,424,426,428],{"key":20,"text":423,"correct":22},"防火风管的密封材料必须为不燃材料",{"key":24,"text":425,"correct":26},"防火分区隔墙两侧的防火阀，距墙表面应不大于250mm",{"key":28,"text":427,"correct":22},"φ700mm防火阀宜设独立支吊架",{"key":31,"text":429,"correct":22},"防排烟系统的柔性短管必须采用不燃材料",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},1112026,"按照国家工程建设消防技术标准的规定，建设单位在验收后应当报消防部门备案的工程是（）。",[434,436,438,440],{"key":20,"text":435,"correct":22},"建筑总面积10000m2的广播电视楼",{"key":24,"text":437,"correct":26},"建筑总面积800m2的中学教学楼",{"key":28,"text":439,"correct":22},"建筑总面积550m2的卡拉OK厅",{"key":31,"text":441,"correct":22},"建筑总面积20000m2的客运车站候车室",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":28,"analysis":33},1112027,"混合储存装置的安装属于（ ）的子分部工程的分项工程。",[446,448,450,452],{"key":20,"text":447,"correct":22},"气体灭火系统",{"key":24,"text":449,"correct":22},"固定消防炮灭火系统",{"key":28,"text":451,"correct":26},"泡沫灭火系统",{"key":31,"text":453,"correct":22},"干粉灭火系统",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":20,"analysis":33},1112028,"自动喷水灭火系统施工程序是：施工准备→（ ）→喷洒分层干、支管安装→喷洒头支管安装→管道试压→管道冲洗→减压装置安装→报警阀配件及其他组件安装→喷洒头安装→系统通水调试等。",[458,460,462,464],{"key":20,"text":459,"correct":26},"干管安装→报警阀安装→立管安装",{"key":24,"text":461,"correct":22},"干管安装→立管安装→报警阀安装",{"key":28,"text":463,"correct":22},"立管安装→报警阀安装→干管安装",{"key":31,"text":465,"correct":22},"立管安装→干管安装→报警阀安装",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":28,"analysis":33},1112029,"建筑总面积2600m2的（ ），不需要申请消防验收。",[470,472,474,476],{"key":20,"text":471,"correct":22},"影剧院",{"key":24,"text":473,"correct":22},"图书馆",{"key":28,"text":475,"correct":26},"宾馆",{"key":31,"text":477,"correct":22},"福利院",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":20,"analysis":33},1112030,"不需要向公安机关消防机构申请消防验收的工程有（ ）。",[482,484,486,488],{"key":20,"text":483,"correct":26},"建筑面积2000m2的影剧院",{"key":24,"text":485,"correct":22},"建筑面积1500m2的托儿所",{"key":28,"text":487,"correct":22},"建筑面积500m2的游艺厅",{"key":31,"text":489,"correct":22},"广播电视楼",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":28,"analysis":33},1112031,"下列关于消防水架空管道施工说法错误的是（ ）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"当管道穿梁安装时，管道用紧固件固定于混凝土结构上",{"key":24,"text":497,"correct":22},"防晃支架的强度，应满足管道.配件及管内水的重量再加50%的水平方向推力时不损坏",{"key":28,"text":499,"correct":26},"DN50的配水干管的防晃支架的间距为18m",{"key":31,"text":501,"correct":22},"管道拐弯时，应增设1个防晃支架。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":31,"analysis":33},1112032,"工程竣工后的建筑消防验收，应检查其消防设施配置等是否符合（ ）的要求。",[506,508,510,512],{"key":20,"text":507,"correct":22},"公安消防部门管理",{"key":24,"text":509,"correct":22},"工程可投入使用或生产",{"key":28,"text":511,"correct":22},"建筑防火等级标准",{"key":31,"text":513,"correct":26},"已获审核批准的消防设计",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":20,"analysis":33},1112033,"喷嘴的安装属于（ ）的子分部工程的分项工程。",[518,519,520,522],{"key":20,"text":447,"correct":26},{"key":24,"text":451,"correct":22},{"key":28,"text":521,"correct":22},"自动喷水灭火系统",{"key":31,"text":523,"correct":22},"消防水炮灭火系统",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":28,"analysis":33},1112034,"水灭火系统中，室内消火栓设置不符合规定的是（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"栓口出水方向宜向下",{"key":24,"text":531,"correct":22},"栓口可以与设置消火栓的墙面成90°角",{"key":28,"text":533,"correct":26},"栓口安装在门轴侧",{"key":31,"text":535,"correct":22},"栓口中心距地面1.1m",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":24,"analysis":33},1112035,"下列需要向公安消防机构申请消防设计审核的是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":22},"建筑面积为8000m2的宾馆",{"key":24,"text":543,"correct":26},"建筑面积为25000m2的展览馆",{"key":28,"text":545,"correct":22},"建筑面积为12000m2的航站楼",{"key":31,"text":547,"correct":22},"建筑面积为10000m2的候车室",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":31,"analysis":33},1112036,"建设单位申请消防验收时应当提供的资料不包括（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":22},"工程竣工图纸",{"key":24,"text":555,"correct":22},"产品质量合格证明",{"key":28,"text":557,"correct":22},"检测合格证明",{"key":31,"text":559,"correct":26},"建设单位资质等级证明",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":31,"analysis":33},1112037,"关于自动喷水灭火系统喷头安装要求的说法，正确的是（）",[564,566,568,570],{"key":20,"text":565,"correct":22},"应在系统试压前安装",{"key":24,"text":567,"correct":22},"安装时可对喷头进行拆装",{"key":28,"text":569,"correct":22},"可给喷头装饰性涂层",{"key":31,"text":571,"correct":26},"不得利用喷头的框架施拧",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":20,"analysis":33},1112038,"电梯的主要技术参数包括（ ）。",[576,578,580,582],{"key":20,"text":577,"correct":26},"额定载重量和额定速度",{"key":24,"text":579,"correct":22},"提升高度和楼层间距",{"key":28,"text":581,"correct":22},"提升高度和额定载重量",{"key":31,"text":583,"correct":22},"楼层间距和额定速度",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":31,"analysis":33},1112039,"电梯安装前，安装单位书面告知的资料不包括（ ）。",[588,590,592,594],{"key":20,"text":589,"correct":22},"安装许可证",{"key":24,"text":591,"correct":22},"安装告知书",{"key":28,"text":593,"correct":22},"施工现场作业人员持有的特种设备作业证",{"key":31,"text":595,"correct":26},"型式试验报告",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":20,"analysis":33},1112040,"关于曳引式电梯安装的施工程序，顺序正确的是（ ）。",[600,602,604,606],{"key":20,"text":601,"correct":26},"设备进场验收→开箱点件→安装样板架.放线→轨道安装",{"key":24,"text":603,"correct":22},"开箱点件→安装样板架.放线→轨道安装→曳引绳安装",{"key":28,"text":605,"correct":22},"轨道安装→轿厢组装→缓冲器和对重装置安装→曳引机和机房其他设备安装",{"key":31,"text":607,"correct":22},"曳引绳安装→缓冲器和对重装置安装→厅门安装→电气装置安装",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":24,"analysis":33},1112041,"关于曳引式电梯安装的验收要求，正确的是（ ）。",[612,614,616,618],{"key":20,"text":613,"correct":22},"对重缓冲器不能延伸到地面实心桩墩上",{"key":24,"text":615,"correct":26},"随机文件包括缓冲器等型式试验证书的复印件",{"key":28,"text":617,"correct":22},"相邻两层门地坎距离大于10m时，应有井道安全门",{"key":31,"text":619,"correct":22},"井道底坑地面能承受满载轿厢静载2倍的重力",[621,624,627,630,633,636],{"id":15,"name":622,"category":7,"favorite":623},"领导干部任职前廉政法规知识测试题",92,{"id":625,"name":626,"category":7,"favorite":15},595,"建筑结构与设备",{"id":628,"name":629,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":631,"name":632,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":634,"name":635,"category":7,"favorite":8},534,"BIM工程师",{"id":637,"name":635,"category":7,"favorite":8},535]