[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-787-37":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":736},{"id":5,"name":6,"category":7,"favorite":8},787,"二建机电工程实务","建筑工程",0,37,50,2160,[13,38,53,68,83,97,112,127,142,157,172,187,201,214,228,243,257,272,286,301,315,327,342,355,369,383,397,412,427,442,456,470,484,498,513,527,541,555,569,583,597,611,626,641,655,670,685,699,708,722],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},1113692,2,"多选题","下列表面处理方法中，属于化学处理的有（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","脱脂",true,{"key":24,"text":25,"correct":26},"B","电化学处理",false,{"key":28,"text":29,"correct":22},"C","浸泡脱脂",{"key":31,"text":32,"correct":22},"D","转化处理",{"key":34,"text":35,"correct":22},"E","超声波脱脂","ACDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},1113693,"一般工业炉窑砌筑，要求砌体砖缝厚度不大于2mm的有（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"煤气管道内衬砖",{"key":24,"text":45,"correct":22},"拱和拱顶",{"key":28,"text":47,"correct":26},"干砌砖",{"key":31,"text":49,"correct":26},"硅藻土砖",{"key":34,"text":51,"correct":22},"高温或有炉渣作用的底和墙","BE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},1113694,"底和墙砌筑的技术要求包括（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"砌筑反拱底前，应用样板找准砌筑弧形拱的基面",{"key":24,"text":60,"correct":26},"斜坡炉底砌筑时，应预砌筑",{"key":28,"text":62,"correct":26},"反拱底从两侧向中心对称砌筑",{"key":31,"text":64,"correct":26},"圆形炉墙应以炉壳为导面进行砌筑",{"key":34,"text":66,"correct":22},"圆形炉墙不得有三层重缝或三环通缝","AE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},1113695,"砌筑工程中，属于持证上岗的特殊工种有（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":22},"起重工",{"key":24,"text":75,"correct":22},"叉车司机",{"key":28,"text":77,"correct":26},"搅拌工",{"key":31,"text":79,"correct":26},"砌筑工",{"key":34,"text":81,"correct":22},"架子工","ABE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":52,"analysis":37},1113696,"冬期施工时，环境温度不低于10℃的耐火浇注料有（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":26},"耐火泥浆",{"key":24,"text":90,"correct":22},"水玻璃耐火浇注料",{"key":28,"text":92,"correct":26},"水泥耐火浇注料",{"key":31,"text":94,"correct":26},"耐火可塑料",{"key":34,"text":96,"correct":22},"磷酸盐耐火浇注料",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":111,"analysis":37},1113697,"制定的烘炉曲线和操作规程主要内容包括（ ）。",[101,103,105,107,109],{"key":20,"text":102,"correct":22},"烘炉期限",{"key":24,"text":104,"correct":22},"升温速度",{"key":28,"text":106,"correct":26},"升温时间",{"key":31,"text":108,"correct":22},"最高温度",{"key":34,"text":110,"correct":22},"烘炉措施","ABDE",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":126,"analysis":37},1113698,"耐火纤维的特点包括（ ）。",[116,118,120,122,124],{"key":20,"text":117,"correct":22},"隔热保温性能好，隔热效率高",{"key":24,"text":119,"correct":22},"化学稳定性好",{"key":28,"text":121,"correct":22},"抗热震性强",{"key":31,"text":123,"correct":26},"塑性好",{"key":34,"text":125,"correct":22},"绝缘性及隔声性能比较好","ABCE",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":141,"analysis":37},1113699,"工业炉烘炉体前应先烘（ ）。",[131,133,135,137,139],{"key":20,"text":132,"correct":26},"进料系统",{"key":24,"text":134,"correct":26},"出料系统",{"key":28,"text":136,"correct":22},"烟囱",{"key":31,"text":138,"correct":22},"烟道",{"key":34,"text":140,"correct":26},"进风系统","CD",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":156,"analysis":37},1113700,"下列资料中，属于砌筑工序交接证明书必须具备的有（ ）。",[146,148,150,152,154],{"key":20,"text":147,"correct":22},"炉子中心线和控制标高的记录",{"key":24,"text":149,"correct":22},"隐蔽工程验收证明记录",{"key":28,"text":151,"correct":22},"托砖板焊接质量检查合格证明",{"key":31,"text":153,"correct":26},"锚固件材质合格证明",{"key":34,"text":155,"correct":26},"炉体的几何尺寸的复查记录","ABC",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":171,"analysis":37},1113701,"静态炉窑与动态炉窑砌筑的不同点有（ ）。",[161,163,165,167,169],{"key":20,"text":162,"correct":22},"不必进行无负荷试运转",{"key":24,"text":164,"correct":26},"根据不同部位和要求可采用干砌或湿砌",{"key":28,"text":166,"correct":26},"锁砖不宜修成楔形",{"key":31,"text":168,"correct":22},"环向缝每次可一次完成",{"key":34,"text":170,"correct":26},"预留膨胀缝","AD",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":186,"analysis":37},1113702,"拱和拱顶的砌筑要点中，正确的有（ ）。",[176,178,180,182,184],{"key":20,"text":177,"correct":22},"从两侧拱脚同时向中心对称砌筑",{"key":24,"text":179,"correct":22},"锁砖应按拱和拱顶中心线对称均匀分布",{"key":28,"text":181,"correct":26},"锁砖深度不宜超过砖长度的2\u002F3",{"key":31,"text":183,"correct":22},"打锁砖时，两侧对称的锁砖应同时均匀打入",{"key":34,"text":185,"correct":26},"锁砖大面宜修成楔形","ABD",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":111,"analysis":37},1113703,"下列耐火浇注料施工的技术要点中，正确的有（ ）。",[191,193,195,197,199],{"key":20,"text":192,"correct":22},"模板接缝应严密，不漏浆",{"key":24,"text":194,"correct":22},"变更用料牌号时，搅拌机、料斗、称量容器等均应冲洗干净",{"key":28,"text":196,"correct":26},"搅拌好的耐火浇注料，应在60min内浇注完成",{"key":31,"text":198,"correct":22},"浇注用的模板应有足够的刚度和强度，支模尺寸应准确",{"key":34,"text":200,"correct":22},"搅拌耐火浇注料的用水应采用洁净水",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":213,"analysis":37},1113704,"烘炉过程中，应根据炉窑的结构和用途、耐火材料的性能、建筑季节等制定烘炉曲线和操作规程。其主要内容包括（ ）",[205,207,209,210,212],{"key":20,"text":206,"correct":22},"恒温时间",{"key":24,"text":208,"correct":26},"动态炉窑的运转情况",{"key":28,"text":104,"correct":22},{"key":31,"text":211,"correct":26},"炉体的膨胀情况",{"key":34,"text":102,"correct":22},"ACE",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":82,"analysis":37},1113705,"工业炉窑砌筑工程工序交接证明书中，合格证明主要包括（ ）。",[218,220,222,224,226],{"key":20,"text":219,"correct":22},"管道和炉壳的试压记录",{"key":24,"text":221,"correct":22},"管道和炉壳的焊接严密性试验",{"key":28,"text":223,"correct":26},"静态式炉窑试运转",{"key":31,"text":225,"correct":26},"炉体冷却装置试运转",{"key":34,"text":227,"correct":22},"炉子可动部分的试运转",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":242,"analysis":37},1113706,"耐火陶瓷纤维施工技术规定包括（ ）。",[232,234,236,238,240],{"key":20,"text":233,"correct":22},"制品不得受潮和挤压",{"key":24,"text":235,"correct":26},"切割制品时，其切口不宜整齐",{"key":28,"text":237,"correct":22},"粘结剂使用时应搅拌均匀",{"key":31,"text":239,"correct":22},"粘切面应均匀涂刷胶粘剂",{"key":34,"text":241,"correct":26},"在耐火陶瓷纤维内衬上施工不定形耐火材料时，其表面应做防火处理","ACD",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":111,"analysis":37},1113707,"砌筑工程冬期施工措施中，正确的有（ ）。",[247,249,251,253,255],{"key":20,"text":248,"correct":22},"应在采暖环境中进行",{"key":24,"text":250,"correct":22},"工作地点和砌体周围温度不应低于5℃",{"key":28,"text":252,"correct":26},"砌筑完成后，若不能立即烘炉，周围温度不应低于0℃",{"key":31,"text":254,"correct":22},"耐火砖和预制块应预热至0℃以上",{"key":34,"text":256,"correct":22},"耐火泥浆施工时的温度不宜低于5℃以上",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":271,"analysis":37},1113708,"避雷带的搭接长度规定有（ ）。",[261,263,265,267,269],{"key":20,"text":262,"correct":26},"扁钢之间搭接为扁钢宽度的1倍",{"key":24,"text":264,"correct":22},"扁钢之间搭接为扁钢宽度的2倍",{"key":28,"text":266,"correct":26},"圆钢之间搭接为圆钢直径的4倍",{"key":31,"text":268,"correct":22},"圆钢之间搭接为圆钢直径的6倍",{"key":34,"text":270,"correct":26},"圆钢与扁钢搭接为圆钢直径的3倍","BD",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":242,"analysis":37},1113709,"建筑电气的子分部包括（ ）。",[276,278,280,282,284],{"key":20,"text":277,"correct":22},"变配电室",{"key":24,"text":279,"correct":26},"成套配电柜",{"key":28,"text":281,"correct":22},"室外电气",{"key":31,"text":283,"correct":22},"电气动力",{"key":34,"text":285,"correct":26},"照明配电箱",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":300,"analysis":37},1113710,"电气照明工程中，管内穿线的施工工序有（ ）等。",[290,292,294,296,298],{"key":20,"text":291,"correct":26},"配管",{"key":24,"text":293,"correct":22},"放护圈",{"key":28,"text":295,"correct":22},"穿引线",{"key":31,"text":297,"correct":22},"穿导线",{"key":34,"text":299,"correct":22},"导线并头","BCDE",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":67,"analysis":37},1113711,"下列关于垂直埋设的人工接地体的施工技术要求，正确的是（ ）。",[305,307,309,311,313],{"key":20,"text":306,"correct":22},"接地体的连接应搭接焊接",{"key":24,"text":308,"correct":26},"接地体的顶部距地面不小于0.7m",{"key":28,"text":310,"correct":26},"垂直接地体的长度一般为2m",{"key":31,"text":312,"correct":26},"用作接地体的镀锌圆钢直径一般为12mm",{"key":34,"text":314,"correct":22},"接地体连接应牢固可靠，有足够的机械强度",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":141,"analysis":37},1113712,"室内照明配电箱的安装技术要求不包括（ ）。 A.照明配电箱内应分别设置零线和保护接地汇流排",[319,321,323,325],{"key":20,"text":320,"correct":26},"零线和保护线在汇流排上连接",{"key":24,"text":322,"correct":26},"照明配电箱内每一单相分支回路的电流不宜超过16",{"key":28,"text":324,"correct":22},"照明配电箱内每一单相分支回路的灯具数量不宜超过10个",{"key":31,"text":326,"correct":22},"大型建筑组合灯具每一单相回路光源数量不宜超过50个",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":341,"analysis":37},1113713,"建筑强电井内的接地支线通常采用（ ）。",[331,333,335,337,339],{"key":20,"text":332,"correct":22},"铜线",{"key":24,"text":334,"correct":22},"铜排",{"key":28,"text":336,"correct":22},"扁钢",{"key":31,"text":338,"correct":22},"圆钢",{"key":34,"text":340,"correct":26},"角钢","ABCD",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":354,"analysis":37},1113714,"关于照明配电箱的安装技术要求，正确的有（ ）。 A.配电箱内应标明用电回路的名称和功率",[346,348,350,352],{"key":20,"text":347,"correct":26},"零线和保护接地线应在汇流排上连接",{"key":24,"text":349,"correct":22},"每个三相分支回路的电流不宜超过16",{"key":28,"text":351,"correct":22},"每个单相分支回路的灯具数量不宜超过25个",{"key":31,"text":353,"correct":22},"插座为单独回路时的插座数量不宜超过10个","BCD",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":156,"analysis":37},1113715,"垂直埋设的金属接地体一般采用（ ）等。",[359,361,363,365,367],{"key":20,"text":360,"correct":22},"镀锌角钢",{"key":24,"text":362,"correct":22},"镀锌钢管",{"key":28,"text":364,"correct":22},"镀锌圆钢",{"key":31,"text":366,"correct":26},"镀锌扁钢",{"key":34,"text":368,"correct":26},"镀锌槽钢",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":111,"analysis":37},1113716,"避雷带在屋顶女儿墙上明敷要求有（ ）。",[373,375,377,379,381],{"key":20,"text":374,"correct":22},"接闪带安装应平正顺直、无急弯",{"key":24,"text":376,"correct":22},"固定支架高度不宜小于150mm",{"key":28,"text":378,"correct":26},"避雷带用25mm×4mm镀锌扁钢",{"key":31,"text":380,"correct":22},"当接闪带采用镀锌扁钢时支架间距为0.5m，采用镀锌圆钢时支架间距为1m",{"key":34,"text":382,"correct":22},"接闪带一般用40mmX4mm镀锌扁钢制作或12mm镀锌圆钢制作",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":111,"analysis":37},1113717,"开关柜、配电柜安装施工技术要求包括（ ）。",[387,389,391,393,395],{"key":20,"text":388,"correct":22},"开关柜、配电柜的基础型钢安装应平直",{"key":24,"text":390,"correct":22},"配电柜与基础型钢间应用镀锌螺栓连接",{"key":28,"text":392,"correct":26},"配电柜安装垂直度允许偏差为1.5%",{"key":31,"text":394,"correct":22},"成列柜面偏差不应大于5mm",{"key":34,"text":396,"correct":22},"高、低压成套配电柜投入运行前必须交接试验合格",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":411,"analysis":37},1113718,"母线槽的施工技术要求包括（ ）。",[401,403,405,407,409],{"key":20,"text":402,"correct":26},"每节母线槽的绝缘电阻值不应小于0.5MΩ",{"key":24,"text":404,"correct":26},"母线槽必须敷设在气体管道和热力管道的下方",{"key":28,"text":406,"correct":22},"水平安装时，每节母线槽的支架不应少于1个",{"key":31,"text":408,"correct":22},"垂直安装时应设置弹簧支承器",{"key":34,"text":410,"correct":22},"母线槽安装完毕后，应对穿越防火墙和楼板的孔洞进行防火封堵","CDE",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":426,"analysis":37},1113719,"梯架、托盘和槽盒施工中，应设置伸缩节的是（ ）。",[416,418,420,422,424],{"key":20,"text":417,"correct":26},"25m钢制梯架",{"key":24,"text":419,"correct":22},"25m铝合金槽盒",{"key":28,"text":421,"correct":26},"20m塑料梯架",{"key":31,"text":423,"correct":22},"20m玻璃钢制梯架",{"key":34,"text":425,"correct":22},"35m塑料梯架","BDE",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":441,"analysis":37},1113720,"插座的接线要求包括（ ）。",[431,433,435,437,439],{"key":20,"text":432,"correct":22},"单相三孔插座，面对插座的右孔应与相线连接",{"key":24,"text":434,"correct":26},"相线与中性导体可利用插座本体的接线端子转接供电",{"key":28,"text":436,"correct":26},"插座的保护接地导体端子与中性导体端子连接",{"key":31,"text":438,"correct":22},"同一场所的三相插座，其接线的相序应一致",{"key":34,"text":440,"correct":22},"保护接地导体在插座之间不得串联连接","ADE",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":441,"analysis":37},1113721,"接闪带（网）的施工技术要求包括（ ）。",[446,448,450,452,454],{"key":20,"text":447,"correct":22},"接闪带一般使用镀锌扁钢或镀锌圆钢制作",{"key":24,"text":449,"correct":26},"接闪带每个固定支架应能承受50N的垂直拉力",{"key":28,"text":451,"correct":26},"扁钢之间搭接长度为扁钢宽度的6倍",{"key":31,"text":453,"correct":22},"接闪带或接闪网在过建筑物变形缝处的跨接应采取补偿措施",{"key":34,"text":455,"correct":22},"屋顶上的金属导体都必须与避雷带连接成一体",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":186,"analysis":37},1113723,"关于导线的敷设要求，正确的有（ ）。",[460,462,464,466,468],{"key":20,"text":461,"correct":22},"管内导线应采用绝缘导线",{"key":24,"text":463,"correct":22},"线路绝缘电阻不应小于0.5MΩ",{"key":28,"text":465,"correct":26},"管内导线总数不应多于10根",{"key":31,"text":467,"correct":22},"导线在管内不应有接头",{"key":34,"text":469,"correct":26},"管内导线不应大于管子截面积的60%",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":82,"analysis":37},1113724,"关于电动机通电前检查的内容，正确的有（ ）。",[474,476,478,480,482],{"key":20,"text":475,"correct":22},"检查电动机定子绕组的连接方法",{"key":24,"text":477,"correct":22},"转动电动机转轴有无摩擦声或其他异声",{"key":28,"text":479,"correct":26},"检查电动机转向应与运转指示箭头一致",{"key":31,"text":481,"correct":26},"检查电动机的温升情况",{"key":34,"text":483,"correct":22},"检查电动机接地是否良好",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":271,"analysis":37},1113725,"下列灯具安装固定方法，可用于安装固定重量为5kg灯具的方法有（ ）。",[488,490,492,494,496],{"key":20,"text":489,"correct":26},"木楔安装固定",{"key":24,"text":491,"correct":22},"预埋吊钩安装固定",{"key":28,"text":493,"correct":26},"尼龙塞安装固定",{"key":31,"text":495,"correct":22},"膨胀螺栓安装固定",{"key":34,"text":497,"correct":26},"塑料塞安装固定",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":512,"analysis":37},1113726,"关于接地干线搭接的焊接要求，正确的有（ ）。",[502,504,506,508,510],{"key":20,"text":503,"correct":26},"扁钢之间搭接为扁钢宽度的2倍，两面施焊",{"key":24,"text":505,"correct":22},"圆钢之间搭接为圆钢直径的6倍，双面施焊",{"key":28,"text":507,"correct":22},"圆钢与扁钢搭接为圆钢直径的6倍，双面施焊",{"key":31,"text":509,"correct":26},"扁钢与钢管搭接，紧贴1\u002F2管外径两侧施焊",{"key":34,"text":511,"correct":26},"扁钢与角钢搭接，紧贴角钢面上两侧施焊","BC",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":271,"analysis":37},1113727,"灯具安装技术要求包括（ ）。",[517,519,521,523,525],{"key":20,"text":518,"correct":26},"灯具安装应牢固，小型灯具可以使用木榫固定",{"key":24,"text":520,"correct":22},"螺口灯头的接线，相线应接在中心触点端子上",{"key":28,"text":522,"correct":26},"II类灯具的金属外壳必须用铜芯软线与保护导体可靠连接",{"key":31,"text":524,"correct":22},"当吊灯灯具重量超过3kg时，应采取预埋吊钩或螺栓固定",{"key":34,"text":526,"correct":26},"质量大于10kg的灯具的固定及悬吊装置应按灯具重量的3倍做恒定均布载荷强度试验",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":242,"analysis":37},1113728,"电动机通电前检查内容包括（ ）。",[531,533,535,537,539],{"key":20,"text":532,"correct":22},"对照电动机铭牌标明的数据检查电动机",{"key":24,"text":534,"correct":26},"接通电源时作好切断电源的准备",{"key":28,"text":536,"correct":22},"检查电动机的启动设备是否良好",{"key":31,"text":538,"correct":22},"转动电动机转轴是否有摩擦声或其他异声",{"key":34,"text":540,"correct":26},"电动机转向应与设备上运转指示箭头一致",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":141,"analysis":37},1113729,"电动机的干燥处理方法有（ ）。",[545,547,549,551,553],{"key":20,"text":546,"correct":26},"油箱铁损法",{"key":24,"text":548,"correct":26},"红外线干燥法",{"key":28,"text":550,"correct":22},"灯泡干燥法",{"key":31,"text":552,"correct":22},"电流干燥法",{"key":34,"text":554,"correct":26},"真空干燥法",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":242,"analysis":37},1113730,"有关导线敷设要求的说法，正确的有（ ）。",[559,561,563,565,567],{"key":20,"text":560,"correct":22},"线路绝缘电阻应大于0.5MΩ",{"key":24,"text":562,"correct":26},"同一台设备的3个电动机的回路可共用一个导管",{"key":28,"text":564,"correct":22},"交流与直流的导线不得穿在同一管内",{"key":31,"text":566,"correct":22},"同一交流回路的导线应穿同一根钢管内",{"key":34,"text":568,"correct":26},"导线在管内的接头应连接牢固",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":82,"analysis":37},1113731,"槽盒内配线技术要求包括（ ）。",[573,575,577,579,581],{"key":20,"text":574,"correct":22},"当垂直或大于45度时倾斜敷设时，应将绝缘导线分段固定在槽盒内的专用部件上",{"key":24,"text":576,"correct":22},"同一槽盒内不宜同时敷设绝缘导线和电缆",{"key":28,"text":578,"correct":26},"槽盒内的绝缘导线总截面积不应超过槽盒内截面积的60%",{"key":31,"text":580,"correct":26},"绝缘导线不得在槽盒内绑扎",{"key":34,"text":582,"correct":22},"槽盒内的分段绝缘导线每段至少应有一个固定点",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":111,"analysis":37},1113733,"下列检查项目中，属于电缆敷设主控项目的有（ ）。",[587,589,591,593,595],{"key":20,"text":588,"correct":22},"电缆的金属支架必须与保护导体可靠连接",{"key":24,"text":590,"correct":22},"分相后的每相电缆不得单独穿于钢导管内",{"key":28,"text":592,"correct":26},"并联使用的电力电缆的型号、规格、长度",{"key":31,"text":594,"correct":22},"电缆沟内的电缆支架层间的最小距离要求",{"key":34,"text":596,"correct":22},"电力电缆的首端、末端和分支处的标志牌",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":186,"analysis":37},1113734,"通风空调设备试运行调试时间符合规定的是（ ）。",[601,603,605,607,609],{"key":20,"text":602,"correct":22},"风机连续运转2h",{"key":24,"text":604,"correct":22},"水泵连续运转2h",{"key":28,"text":606,"correct":26},"冷却水系统循环试运行不少于8h",{"key":31,"text":608,"correct":22},"制冷机组试运转不少于8h",{"key":34,"text":610,"correct":26},"通风系统的连续试运行应不少于8h",{"id":612,"libraryId":5,"type":15,"typeLabel":16,"stem":613,"options":614,"answer":625,"analysis":37},1113735,"洁净空调系统风管的所有（ ）均必须涂密封胶。",[615,617,619,621,623],{"key":20,"text":616,"correct":26},"法兰连接处",{"key":24,"text":618,"correct":22},"咬口缝",{"key":28,"text":620,"correct":22},"翻边处",{"key":31,"text":622,"correct":26},"焊接缝",{"key":34,"text":624,"correct":22},"铆钉处","BCE",{"id":627,"libraryId":5,"type":15,"typeLabel":16,"stem":628,"options":629,"answer":640,"analysis":37},1113736,"防、排烟系统或输送含有腐蚀介质的气体，应采用（ ）。",[630,632,634,636,638],{"key":20,"text":631,"correct":22},"软聚氯乙烯板",{"key":24,"text":633,"correct":22},"耐酸橡胶板",{"key":28,"text":635,"correct":26},"耐热橡胶板",{"key":31,"text":637,"correct":26},"不燃的耐温材料",{"key":34,"text":639,"correct":26},"防火材料","AB",{"id":642,"libraryId":5,"type":15,"typeLabel":16,"stem":643,"options":644,"answer":111,"analysis":37},1113737,"洁净空调工程调试前，通风空调系统运转所需的（ ）等已具备。",[645,647,649,651,653],{"key":20,"text":646,"correct":22},"用水",{"key":24,"text":648,"correct":22},"用电",{"key":28,"text":650,"correct":26},"油路通",{"key":31,"text":652,"correct":22},"用汽",{"key":34,"text":654,"correct":22},"压缩空气",{"id":656,"libraryId":5,"type":15,"typeLabel":16,"stem":657,"options":658,"answer":669,"analysis":37},1113739,"洁净空调系统的风管连接处必须严密，法兰垫料应采用（ ）的弹性材料。",[659,661,663,665,667],{"key":20,"text":660,"correct":26},"耐油橡胶",{"key":24,"text":662,"correct":26},"耐酸橡胶",{"key":28,"text":664,"correct":26},"硬质光滑",{"key":31,"text":666,"correct":22},"不产尘",{"key":34,"text":668,"correct":22},"不易老化","DE",{"id":671,"libraryId":5,"type":15,"typeLabel":16,"stem":672,"options":673,"answer":684,"analysis":37},1113740,"高效过滤器安装时要保证滤料的（ ）。",[674,676,678,680,682],{"key":20,"text":675,"correct":26},"湿度",{"key":24,"text":677,"correct":26},"密封",{"key":28,"text":679,"correct":22},"清洁",{"key":31,"text":681,"correct":26},"软性度",{"key":34,"text":683,"correct":22},"严密","CE",{"id":686,"libraryId":5,"type":15,"typeLabel":16,"stem":687,"options":688,"answer":186,"analysis":37},1113741,"风管安装要求包括（ ）。",[689,691,693,695,697],{"key":20,"text":690,"correct":22},"风阀安装方向正确、便于操作，启闭灵活",{"key":24,"text":692,"correct":22},"吊装组对风管时，应保证吊装稳定，必要时应采取防止变形的措施",{"key":28,"text":694,"correct":26},"防、排烟系统或输送温度高于70℃的空气或烟气的，应采用橡胶板",{"key":31,"text":696,"correct":22},"风管穿过封闭防火防爆楼板时的预埋套管，其钢板厚度不小于1.6mm",{"key":34,"text":698,"correct":26},"穿越建筑物变形缝墙体的风管与套管之间，应采用柔性材料填充密实",{"id":700,"libraryId":5,"type":15,"typeLabel":16,"stem":701,"options":702,"answer":411,"analysis":37},1113742,"防、排烟系统或输送温度高于70℃的空气或烟气，应采用（ ）。",[703,704,705,706,707],{"key":20,"text":631,"correct":26},{"key":24,"text":633,"correct":26},{"key":28,"text":635,"correct":22},{"key":31,"text":637,"correct":22},{"key":34,"text":639,"correct":22},{"id":709,"libraryId":5,"type":15,"typeLabel":16,"stem":710,"options":711,"answer":213,"analysis":37},1113743,"风管系统制作的一般要求包括（ ）。",[712,714,716,718,720],{"key":20,"text":713,"correct":22},"复合风管板材的覆面材料必须为不燃材料",{"key":24,"text":715,"correct":26},"风管与配件的制作宜选用电气焊切割",{"key":28,"text":717,"correct":22},"风管与法兰连接采用铆接或焊接",{"key":31,"text":719,"correct":26},"中、低压系统矩形法兰螺栓及铆钉间距不小于150mm",{"key":34,"text":721,"correct":22},"板厚大于1.5mm的风管采用电焊、氩弧焊",{"id":723,"libraryId":5,"type":15,"typeLabel":16,"stem":724,"options":725,"answer":411,"analysis":37},1113744,"金属风管板材的拼接要求有（ ）。",[726,728,730,732,734],{"key":20,"text":727,"correct":26},"金属风管板材的拼接采用咬口连接、搭接等方法",{"key":24,"text":729,"correct":26},"风管与风管连接采用焊接",{"key":28,"text":731,"correct":22},"板材连接缝应该达到缝线顺直、平整",{"key":31,"text":733,"correct":22},"不露保温层",{"key":34,"text":735,"correct":22},"满足和结构连接的强度要求",[737,741,744,747,750,753],{"id":738,"name":739,"category":7,"favorite":740},1,"领导干部任职前廉政法规知识测试题",92,{"id":742,"name":743,"category":7,"favorite":738},595,"建筑结构与设备",{"id":745,"name":746,"category":7,"favorite":738},715,"招标采购专业知识与法律法规",{"id":748,"name":749,"category":7,"favorite":738},848,"市政方向-通用基础",{"id":751,"name":752,"category":7,"favorite":8},534,"BIM工程师",{"id":754,"name":752,"category":7,"favorite":8},535]