[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-787-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":619},{"id":5,"name":6,"category":7,"favorite":8},787,"二建机电工程实务","建筑工程",0,26,50,2160,[13,34,46,58,70,82,94,106,118,130,141,153,165,177,189,201,213,225,237,249,261,273,285,297,309,321,333,345,357,369,381,393,405,417,429,441,453,465,477,489,501,513,524,536,548,559,571,583,595,607],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1113123,1,"单选题","炉窑砌砖中断或返工时，中断或返工处的耐火砖应做成（）。2015",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","平齐一致直槎",false,{"key":24,"text":25,"correct":26},"B","梯形斜槎",true,{"key":28,"text":29,"correct":22},"C","椭圆角直槎",{"key":31,"text":32,"correct":22},"D","马形斜槎","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1113124,"回转式炉窑砌筑时，砌筑的起始点宜选择在（）。2016",[38,40,42,44],{"key":20,"text":39,"correct":22},"离传动最近的焊缝处",{"key":24,"text":41,"correct":22},"检修门（孔）处",{"key":28,"text":43,"correct":26},"工作温度的热端",{"key":31,"text":45,"correct":22},"支撑位置",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1113125,"下列炉窑砌筑工序中不属于交接内容的是（）。2012",[50,52,54,56],{"key":20,"text":51,"correct":22},"上道工序成果的保护要求",{"key":24,"text":53,"correct":26},"耐火材料的验收",{"key":28,"text":55,"correct":22},"炉子中心线及控制高程测量记录",{"key":31,"text":57,"correct":22},"炉子可动部分试运转合格证明",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1113126,"炉窑砌筑时，起拱跨度大于5m时，拱和拱顶应打入（）锁砖。",[62,64,66,68],{"key":20,"text":63,"correct":22},"2块",{"key":24,"text":65,"correct":26},"3块",{"key":28,"text":67,"correct":22},"5块",{"key":31,"text":69,"correct":22},"6块",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1113127,"在耐火陶瓷纤维内衬上施工不定形耐火材料时，其表面应做（）。2017",[74,76,78,80],{"key":20,"text":75,"correct":22},"绝热处理",{"key":24,"text":77,"correct":26},"防水处理",{"key":28,"text":79,"correct":22},"防火处理",{"key":31,"text":81,"correct":22},"防腐处理",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},1113128,"下列耐火材料中，属于中性耐火材料的是（）。2014",[86,88,90,92],{"key":20,"text":87,"correct":26},"高铝砖",{"key":24,"text":89,"correct":22},"镁铝砖",{"key":28,"text":91,"correct":22},"硅砖",{"key":31,"text":93,"correct":22},"白云石砖",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1113129,"下列关于耐火喷涂料施工技术要求的说法，错误的是（）。【2018】",[98,100,102,104],{"key":20,"text":99,"correct":26},"喷涂方向与受喷面成60°～75°夹角",{"key":24,"text":101,"correct":22},"喷涂应分段连续进行",{"key":28,"text":103,"correct":22},"喷涂料应采用半干法喷涂",{"key":31,"text":105,"correct":22},"施工中断时，宜将接槎处做成直槎",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1113130,"关于建筑管道工程系统试验的说法，正确的是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"管道的压力试验应在无损检测前进行",{"key":24,"text":113,"correct":26},"通球试验的球径不小于排水管径的2\u002F3",{"key":28,"text":115,"correct":22},"高层建筑管道施工结束后应立即进行调整试验",{"key":31,"text":117,"correct":22},"室内埋地排水管道投用前必须做灌水试验",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1113131,"室内卫生器具的排水支管隐蔽前必须做（）2012",[122,124,126,128],{"key":20,"text":123,"correct":22},"压力试验",{"key":24,"text":125,"correct":26},"灌水试验",{"key":28,"text":127,"correct":22},"通球试验",{"key":31,"text":129,"correct":22},"泄露试验",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},1113132,"检验管道系统强度和严密性的试验是（）。2013",[134,135,137,139],{"key":20,"text":123,"correct":26},{"key":24,"text":136,"correct":22},"真空度试验",{"key":28,"text":138,"correct":22},"侧漏性试验",{"key":31,"text":140,"correct":22},"致密性试验",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":33},1113133,"高层建筑给水及排水铸铁管的柔性连接应采用（）。2014",[145,147,149,151],{"key":20,"text":146,"correct":22},"石棉水泥密封",{"key":24,"text":148,"correct":26},"橡胶圈密封",{"key":28,"text":150,"correct":22},"铅密封",{"key":31,"text":152,"correct":22},"膨胀性填料密封",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":31,"analysis":33},1113134,"建筑管道配管的施工原则是（）。2011",[157,159,161,163],{"key":20,"text":158,"correct":22},"大管让小管",{"key":24,"text":160,"correct":22},"风管让水管",{"key":28,"text":162,"correct":22},"无压管让有压管",{"key":31,"text":164,"correct":26},"电管让水管",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":20,"analysis":33},1113135,"安装在易受震动场所的雨水管道使用（）。2013",[169,171,173,175],{"key":20,"text":170,"correct":26},"钢管",{"key":24,"text":172,"correct":22},"铸铁管",{"key":28,"text":174,"correct":22},"塑料管",{"key":31,"text":176,"correct":22},"波纹管",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},1113136,"高层建筑管道工程施工程序中，管道支架安装的紧后工序是（）。",[181,183,185,187],{"key":20,"text":182,"correct":22},"管道测绘放线",{"key":24,"text":184,"correct":26},"管道元件检验",{"key":28,"text":186,"correct":22},"管道加工预制",{"key":31,"text":188,"correct":22},"管道元件安装",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":28,"analysis":33},1113137,"具有保护水质卫生、抗腐蚀性强、使用寿命长等特点的管件是（）。",[193,195,197,199],{"key":20,"text":194,"correct":22},"铸铁连接管件",{"key":24,"text":196,"correct":22},"镀锌法兰管件",{"key":28,"text":198,"correct":26},"不锈钢卡压式管件",{"key":31,"text":200,"correct":22},"沟槽式管件",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":31,"analysis":33},1113138,"明敷管道横干管穿越防火分区隔墙时，管道穿越墙体的两侧应隔墙设置防火套管的长度，可用的是（）。2015",[205,207,209,211],{"key":20,"text":206,"correct":22},"20mm",{"key":24,"text":208,"correct":22},"30mm",{"key":28,"text":210,"correct":22},"40mm",{"key":31,"text":212,"correct":26},"500mm",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":24,"analysis":33},1113139,"避雷器安装的检查要求，正确的是（）。2015",[217,219,221,223],{"key":20,"text":218,"correct":22},"避雷器应拆开检查",{"key":24,"text":220,"correct":26},"避雷器额定电压与线路电压相等",{"key":28,"text":222,"correct":22},"避雷器防爆片的上下盖不能取下",{"key":31,"text":224,"correct":22},"避雷器裂纹应小于1m",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":24,"analysis":33},1113140,"高层建筑为防止侧击雷电，应在环绕建筑物周边设置（）2014",[229,231,233,235],{"key":20,"text":230,"correct":22},"避雷针",{"key":24,"text":232,"correct":26},"均压环",{"key":28,"text":234,"correct":22},"接地线",{"key":31,"text":236,"correct":22},"引下线",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":28,"analysis":33},1113141,"室内照明灯具的施工程序中，灯具安装接线的紧后工序是（）。2015",[241,243,245,247],{"key":20,"text":242,"correct":22},"导线并头",{"key":24,"text":244,"correct":22},"绝缘测试",{"key":28,"text":246,"correct":26},"送电前检查",{"key":31,"text":248,"correct":22},"灯管安装",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":31,"analysis":33},1113142,"电气设备的独立接地体，其接地电阻应小于（）。",[253,255,257,259],{"key":20,"text":254,"correct":22},"1Ω",{"key":24,"text":256,"correct":22},"2Ω",{"key":28,"text":258,"correct":22},"3Ω",{"key":31,"text":260,"correct":26},"4Ω",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},1113143,"建筑电气装置施工中，成套配电柜安装固定后的紧后工序是（）。2011",[265,267,269,271],{"key":20,"text":266,"correct":22},"开箱检查",{"key":24,"text":268,"correct":26},"母线安装",{"key":28,"text":270,"correct":22},"调整试验",{"key":31,"text":272,"correct":22},"送电运行",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":28,"analysis":33},1113145,"通风系统按空气动力不同分为（）和机械通风。2015",[277,279,281,283],{"key":20,"text":278,"correct":22},"工业通风",{"key":24,"text":280,"correct":22},"换气通风",{"key":28,"text":282,"correct":26},"自然通风",{"key":31,"text":284,"correct":22},"全面通风",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":28,"analysis":33},1113146,"通风与空调系统经平衡调整后，各风口的总风量与设计风量的允许偏差不应大于（）。2014",[289,291,293,295],{"key":20,"text":290,"correct":22},"5%",{"key":24,"text":292,"correct":22},"10%",{"key":28,"text":294,"correct":26},"15%",{"key":31,"text":296,"correct":22},"20%",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":28,"analysis":33},1113147,"复合风管采用的不燃材料覆面与绝热材料不包括（）。",[301,303,305,307],{"key":20,"text":302,"correct":22},"聚氨脂铝箔",{"key":24,"text":304,"correct":22},"酚醛铝箔",{"key":28,"text":306,"correct":26},"铝塑复合板",{"key":31,"text":308,"correct":22},"玻璃纤维复合板",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":31,"analysis":33},1113148,"风管穿过需要封闭的防火防爆楼板或墙体时，应设钢板厚度不小于（）的预埋管或防护套管，风管与套管之间应采用不燃柔性材料密封。",[313,315,317,319],{"key":20,"text":314,"correct":22},"1.0mm",{"key":24,"text":316,"correct":22},"1.2mm",{"key":28,"text":318,"correct":22},"1.4mm",{"key":31,"text":320,"correct":26},"1.6mm",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":20,"analysis":33},1113149,"风管系统安装的紧后工序是：（）。",[325,327,329,331],{"key":20,"text":326,"correct":26},"风管系统严密性试验",{"key":24,"text":328,"correct":22},"空调设备安装",{"key":28,"text":330,"correct":22},"空调水系统安装",{"key":31,"text":332,"correct":22},"管道防腐与绝热",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":28,"analysis":33},1113150,"风管型压力、压差传感器应在应在风管（）完成后进行安装。",[337,339,341,343],{"key":20,"text":338,"correct":22},"安装",{"key":24,"text":340,"correct":22},"试验",{"key":28,"text":342,"correct":26},"保温层",{"key":31,"text":344,"correct":22},"防腐",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},1113151,"在有强磁场干扰的区域，模拟信号传输电缆应采用（）。2015",[349,351,353,355],{"key":20,"text":350,"correct":22},"多股线",{"key":24,"text":352,"correct":26},"屏蔽线",{"key":28,"text":354,"correct":22},"双绞线",{"key":31,"text":356,"correct":22},"平行线",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":31,"analysis":33},1113152,"建筑智能化系统验收时，有线电视系统应包括的验收文件是（）。2016",[361,363,365,367],{"key":20,"text":362,"correct":22},"控制箱接线图",{"key":24,"text":364,"correct":22},"防雷保护设备布置图",{"key":28,"text":366,"correct":22},"机柜设备装配图",{"key":31,"text":368,"correct":26},"用户分配电平图",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":31,"analysis":33},1113153,"空调设备自动监控中的温度传感器是通过变送器将其温度变化信号转换成（）电信号。2013",[373,375,377,379],{"key":20,"text":374,"correct":22},"0～10mA",{"key":24,"text":376,"correct":22},"0～20mA",{"key":28,"text":378,"correct":22},"0～10VAC",{"key":31,"text":380,"correct":26},"0～10VDC",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":24,"analysis":33},1113154,"将4个1kΩ（21℃）镍电阻两串联再并联后，检测一个大房间的平均温度（21℃），传递到变送器的电阻值是（）2014",[385,387,389,391],{"key":20,"text":386,"correct":22},"0.5kΩ",{"key":24,"text":388,"correct":26},"1.0kΩ",{"key":28,"text":390,"correct":22},"2.0kΩ",{"key":31,"text":392,"correct":22},"4.0kΩ",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":28,"analysis":33},1113155,"建筑智能化集成系统验收文件中，不包括的文件是（ ）。2019",[397,399,401,403],{"key":20,"text":398,"correct":22},"应用软件文档",{"key":24,"text":400,"correct":22},"接口技术文件",{"key":28,"text":402,"correct":26},"防火墙配备文件",{"key":31,"text":404,"correct":22},"接口测试文件",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":20,"analysis":33},1113156,"属于消防工程避难设施的是（）。2015",[409,411,413,415],{"key":20,"text":410,"correct":26},"应急照明装置",{"key":24,"text":412,"correct":22},"手动报警按钮",{"key":28,"text":414,"correct":22},"自动喷淋设施",{"key":31,"text":416,"correct":22},"感火探测器",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":20,"analysis":33},1113157,"下列设备中，属于气体灭火系统的是（）。2013",[421,423,425,427],{"key":20,"text":422,"correct":26},"贮存容器",{"key":24,"text":424,"correct":22},"发生装置",{"key":28,"text":426,"correct":22},"比例混合器",{"key":31,"text":428,"correct":22},"过滤器",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":31,"analysis":33},1113158,"下列总面积在1000～2000m2的建筑场所应申请消防验收的是( )2016",[433,435,437,439],{"key":20,"text":434,"correct":22},"医院的门诊楼",{"key":24,"text":436,"correct":22},"博物馆的展示厅",{"key":28,"text":438,"correct":22},"大学的食堂",{"key":31,"text":440,"correct":26},"中学的教学楼",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":31,"analysis":33},1113159,"下列建设工程，不需要申请消防设计审核的是（）。2017",[445,447,449,451],{"key":20,"text":446,"correct":22},"政府办公楼",{"key":24,"text":448,"correct":22},"城市轨道交通",{"key":28,"text":450,"correct":22},"20㎡中学图书馆",{"key":31,"text":452,"correct":26},"6层住宅楼",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":24,"analysis":33},1113160,"按照国家工程建设消防技术标准的规定，建设单位在验收后应当报消防部门备案的工程是（）。2018",[457,459,461,463],{"key":20,"text":458,"correct":22},"建筑总面积10000m2的广播电视楼",{"key":24,"text":460,"correct":26},"建筑总面积800m2的中学教学楼",{"key":28,"text":462,"correct":22},"建筑总面积550m2的卡拉OK厅",{"key":31,"text":464,"correct":22},"建筑总面积20000m2的客运车站候车室",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":28,"analysis":33},1113161,"下列消防产品中，无须通过强制认证（3C 认证）的是（ ）。2019",[469,471,473,475],{"key":20,"text":470,"correct":22},"消防应急照明灯具",{"key":24,"text":472,"correct":22},"消防排烟风机",{"key":28,"text":474,"correct":26},"消防加压送风口",{"key":31,"text":476,"correct":22},"防火涂料",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":31,"analysis":33},1113162,"（2020年真题）下列消防系统调试内容中，不属于自动喷水灭火系统的是（ ）。",[481,483,485,487],{"key":20,"text":482,"correct":22},"稳压泵调试",{"key":24,"text":484,"correct":22},"消防水泵调试",{"key":28,"text":486,"correct":22},"排水设施调试",{"key":31,"text":488,"correct":26},"喷射功能调试",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":20,"analysis":33},1113163,"自动扶梯进行空载制动试验时，（）应符合标准规范的要求。",[493,495,497,499],{"key":20,"text":494,"correct":26},"制停距离",{"key":24,"text":496,"correct":22},"制停速度",{"key":28,"text":498,"correct":22},"制停时间",{"key":31,"text":500,"correct":22},"制停载荷",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":20,"analysis":33},1113164,"曳引式电梯设备进场验收合格后，在驱动主机安装前的工序是（）。2015",[505,507,509,511],{"key":20,"text":506,"correct":26},"土建交换检验",{"key":24,"text":508,"correct":22},"导轨安装",{"key":28,"text":510,"correct":22},"对重安装",{"key":31,"text":512,"correct":22},"安全部件安装",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":20,"analysis":33},1113165,"曳引式电梯设备进场验收合格后，在驱动主机安装前的工序是（）2014",[517,519,521,523],{"key":20,"text":518,"correct":26},"土建交接检验",{"key":24,"text":520,"correct":22},"轿厢导轨安装",{"key":28,"text":522,"correct":22},"随行电缆安装",{"key":31,"text":512,"correct":22},{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":24,"analysis":33},1113166,"自动扶梯在额定频率和额定电压下，梯级沿运行方向空载时的速度与额定速度之间的允许偏差为（）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"±2.5%",{"key":24,"text":531,"correct":26},"±5%",{"key":28,"text":533,"correct":22},"±7.5%",{"key":31,"text":535,"correct":22},"±10%",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":20,"analysis":33},1113167,"自动人行道自动停止运行时，开关断开的动作不用通过安全触点或安全电器来完成的是（）。2018",[540,542,544,546],{"key":20,"text":541,"correct":26},"过载",{"key":24,"text":543,"correct":22},"踏板下陷",{"key":28,"text":545,"correct":22},"扶手带入口保护装置动作",{"key":31,"text":547,"correct":22},"附加制动器动作",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":20,"analysis":33},1113168,"下列子分部工程中，不属于液压电梯安装工程的是（）。2017",[552,554,556,557],{"key":20,"text":553,"correct":26},"补偿装置安装",{"key":24,"text":555,"correct":22},"悬挂装置安装",{"key":28,"text":508,"correct":22},{"key":31,"text":558,"correct":22},"对重（平衡重）安装",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":24,"analysis":33},1113169,"关于曳引式电梯安装的验收要求，正确的是（）。2016",[563,565,567,569],{"key":20,"text":564,"correct":22},"对重缓冲器不能延伸到地面实心桩墩上",{"key":24,"text":566,"correct":26},"随机文件包括缓冲器等型式试验证书的复印件",{"key":28,"text":568,"correct":22},"相邻两层门地坎距离大于10m时，应有井道安全门",{"key":31,"text":570,"correct":22},"井道地坑地面能承受满载轿厢静载2倍的重力",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":20,"analysis":33},1113170,"自动扶梯的梯级踏板上空，垂直净高度严禁小于（）。",[575,577,579,581],{"key":20,"text":576,"correct":26},"2.3m",{"key":24,"text":578,"correct":22},"2.6m",{"key":28,"text":580,"correct":22},"2.8m",{"key":31,"text":582,"correct":22},"3.0m",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":31,"analysis":33},1113171,"关于电梯整机验收要求的说法，错误的是（ ）。2019",[587,589,591,593],{"key":20,"text":588,"correct":22},"电梯的动力电路必须有过载保护装置",{"key":24,"text":590,"correct":22},"断相保护装置应使电梯不发生危险故障",{"key":28,"text":592,"correct":22},"电梯门锁装置必须与其型式试验证书相符",{"key":31,"text":594,"correct":26},"限速器在联动试验中应使电梯主机延时制动",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":31,"analysis":33},1113172,"（2020年真题）电梯渐进式安全钳动作试验的载荷为（ ）。",[599,601,603,605],{"key":20,"text":600,"correct":22},"50%额定载重量",{"key":24,"text":602,"correct":22},"100%额定载重量",{"key":28,"text":604,"correct":22},"110%额定载重量",{"key":31,"text":606,"correct":26},"125%额定载重量",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":31,"analysis":33},1113173,"投标人的下列情况，不应作为废标处理的是（）。2017",[611,613,615,617],{"key":20,"text":612,"correct":22},"资产负债率大于招标要求",{"key":24,"text":614,"correct":22},"投标报价低于其个别成本",{"key":28,"text":616,"correct":22},"投标安全文明施工费低于招标要求",{"key":31,"text":618,"correct":26},"投标工期短于招标要求",[620,623,626,629,632,635],{"id":15,"name":621,"category":7,"favorite":622},"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":15},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]