[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-787-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":604},{"id":5,"name":6,"category":7,"favorite":8},787,"二建机电工程实务","建筑工程",0,21,50,2160,[13,34,46,58,70,82,94,106,118,130,141,151,163,175,187,199,211,223,235,247,259,271,283,291,303,315,327,339,351,363,375,387,399,411,423,435,445,457,469,481,493,504,512,524,536,548,560,568,580,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1112868,1,"单选题","计量器具经检定机构检定后出具的（ ）是证明计量器具不符合有关法定要求的文件。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","检定证书",false,{"key":24,"text":25,"correct":26},"B","检定结果通知书",true,{"key":28,"text":29,"correct":22},"C","漆封印",{"key":31,"text":32,"correct":22},"D","钳印","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1112869,"下列计量器具中，属于A类范围的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"水平仪检具",{"key":24,"text":41,"correct":22},"经纬仪",{"key":28,"text":43,"correct":22},"焊接检验尺",{"key":31,"text":45,"correct":22},"水准仪",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},1112870,"下列计量器具中，属于B类范围的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"兆欧表",{"key":24,"text":53,"correct":22},"接地电阻测量仪",{"key":28,"text":55,"correct":26},"欧姆表",{"key":31,"text":57,"correct":22},"X射线探伤机",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1112871,"施工现场计量器具的管理过程中，计量器具发到班组后，应（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"调校及使用",{"key":24,"text":65,"correct":22},"对比",{"key":28,"text":67,"correct":22},"建档",{"key":31,"text":69,"correct":22},"保管",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},1112872,"计量检测设备每次使用前应（ ）检查后，方可开始计量测试。",[74,76,78,80],{"key":20,"text":75,"correct":22},"认真清扫",{"key":24,"text":77,"correct":22},"对零部件",{"key":28,"text":79,"correct":22},"对使用场地",{"key":31,"text":81,"correct":26},"校准对零",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1112873,"重新启用被封存的计量检测设备，必须（ ），方可使用。",[86,88,90,92],{"key":20,"text":87,"correct":22},"确认其有合格证后",{"key":24,"text":89,"correct":26},"经检定合格后",{"key":28,"text":91,"correct":22},"经主管领导同意后",{"key":31,"text":93,"correct":22},"确认封存前是合格的",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1112874,"施工现场根据（ ）和实际使用情况，合理安排好每种计量器具的检定周期。",[98,100,102,104],{"key":20,"text":99,"correct":26},"计量检定规程",{"key":24,"text":101,"correct":22},"设计要求",{"key":28,"text":103,"correct":22},"计量器具种类",{"key":31,"text":105,"correct":22},"精度等级",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},1112875,"对电容类仪器、仪表，应经常检查（ ）和接地，对长期不使用的电器仪表要定期检查、通电、排潮，防止霉烂。",[110,112,114,116],{"key":20,"text":111,"correct":22},"外观",{"key":24,"text":113,"correct":22},"电路",{"key":28,"text":115,"correct":26},"绝缘性能",{"key":31,"text":117,"correct":22},"温度",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1112876,"企业强制检定的计量器具范围是（ ）计量标准器具。",[122,124,126,128],{"key":20,"text":123,"correct":22},"重要",{"key":24,"text":125,"correct":26},"最高",{"key":28,"text":127,"correct":22},"常用",{"key":31,"text":129,"correct":22},"新型",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},1112877,"下列工作计量器具中，属于非强制检定的是（ ）。",[134,135,137,139],{"key":20,"text":51,"correct":22},{"key":24,"text":136,"correct":22},"声级计",{"key":28,"text":138,"correct":26},"电压表",{"key":31,"text":140,"correct":22},"绝缘电阻表",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":33},1112878,"下列计量器具中，属于企业最高计量标准器的是（ ）。",[145,146,147,149],{"key":20,"text":53,"correct":26},{"key":24,"text":43,"correct":22},{"key":28,"text":148,"correct":22},"超声波测厚仪",{"key":31,"text":150,"correct":22},"直流电位差计",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":28,"analysis":33},1112879,"施工企业租用的或由建设方或总包方提供的计量器具，因附带该设备有效期内的（ ）方可使用。",[155,157,159,161],{"key":20,"text":156,"correct":22},"批准生产编号",{"key":24,"text":158,"correct":22},"出厂合格证",{"key":28,"text":160,"correct":26},"检定合格印",{"key":31,"text":162,"correct":22},"生产许可证标志",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":24,"analysis":33},1112880,"关于施工计量器具使用的管理规定，正确的是（ ）。",[167,169,171,173],{"key":20,"text":168,"correct":22},"非强制检定，不必检定",{"key":24,"text":170,"correct":26},"非强制检定计量器具的检定周期，由企业自行确定",{"key":28,"text":172,"correct":22},"企业、事业单位建立本单位各项最高计量标准，须向省级人民政府计量行政部门申请考核",{"key":31,"text":174,"correct":22},"不准在教学工作岗位上使用无检定合格印、证或者超过检定周期的计量器具",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":28,"analysis":33},1112881,"依据国家对强制检定的计量器具检定周期的规定，以及企业自有的计量管理制度，对检测器具进行（ ）、校验，以防止检测器具的自身误差而造成工程质量不合格。",[179,181,183,185],{"key":20,"text":180,"correct":22},"后续检定",{"key":24,"text":182,"correct":22},"使用检定",{"key":28,"text":184,"correct":26},"周期检定",{"key":31,"text":186,"correct":22},"仲裁检定",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":20,"analysis":33},1112882,"非强制检定的计量器具未经检定的以及经检定不合格继续使用的处以罚款和（ ）。",[191,193,195,197],{"key":20,"text":192,"correct":26},"责令停止使用",{"key":24,"text":194,"correct":22},"没收检定印、证",{"key":28,"text":196,"correct":22},"没收计量器具",{"key":31,"text":198,"correct":22},"追究刑事责任",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":31,"analysis":33},1112883,"项目经理部专（兼）职计量管理员对施工使用的计量器具进行的管理内容不包括（ ）。",[203,205,207,209],{"key":20,"text":204,"correct":22},"建立现场使用计量器具台账",{"key":24,"text":206,"correct":22},"负责现场使用计量器具周期检定",{"key":28,"text":208,"correct":22},"负责现场巡视计量器具的完好状态",{"key":31,"text":210,"correct":26},"办理不合格计量器具的报废手续",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":33},1112884,"临时用电施工组织设计应由电气技术人员编制，（ ）审核，经主管部门批准后实施。",[215,217,219,221],{"key":20,"text":216,"correct":22},"电气工程师",{"key":24,"text":218,"correct":26},"项目技术负责人",{"key":28,"text":220,"correct":22},"项目经理",{"key":31,"text":222,"correct":22},"监理工程师",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":24,"analysis":33},1112885,"有关电力线路保护区说法，不正确的是（ ）。",[227,229,231,233],{"key":20,"text":228,"correct":22},"电压在110kV的架空电力线路保护区是导线边缘向外侧延伸的距离为10m",{"key":24,"text":230,"correct":26},"地下电缆为电缆线路地面标桩两侧各1m所形成的两平行线内的区域",{"key":28,"text":232,"correct":22},"江河电缆一般不小于线路两侧各100m所形成的两平行线内的水域",{"key":31,"text":234,"correct":22},"不得在距电力设施周围500m范围内进行爆破作业",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":24,"analysis":33},1112886,"施工单位应根据国家有关标准、规范和施工现场的实际负荷情况，编制施工现场“临时用电施工组织设计”，并协助业主向当地电业部门（ ）。",[239,241,243,245],{"key":20,"text":240,"correct":22},"申请用电许可",{"key":24,"text":242,"correct":26},"申报用电方案",{"key":28,"text":244,"correct":22},"申报用电额度",{"key":31,"text":246,"correct":22},"申请用电安全评审",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":31,"analysis":33},1112887,"在电力设施保护区内允许取土的范围内取土时，所形成的坡面与地平线之间的夹角，一般不得大于（ ）。",[251,253,255,257],{"key":20,"text":252,"correct":22},"30°",{"key":24,"text":254,"correct":22},"35°",{"key":28,"text":256,"correct":22},"40°",{"key":31,"text":258,"correct":26},"45°",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":31,"analysis":33},1112888,"供电方案的有效期，是指从供电方案正式通知书发出之日起至交纳供电贴费并受电工程开工日为止。高压供电方案的有效期为（ ），逾期注销。",[263,265,267,269],{"key":20,"text":264,"correct":22},"3个月",{"key":24,"text":266,"correct":22},"6个月",{"key":28,"text":268,"correct":22},"9个月",{"key":31,"text":270,"correct":26},"12个月",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":28,"analysis":33},1112889,"电压在220kV的架空电力线路保护区是指：导线边缘向外侧延伸的距离为（ ）。",[275,277,279,281],{"key":20,"text":276,"correct":22},"5m",{"key":24,"text":278,"correct":22},"10m",{"key":28,"text":280,"correct":26},"15m",{"key":31,"text":282,"correct":22},"20m",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":31,"analysis":33},1112890,"电压在500kV的架空电力线路保护区是指：导线边缘向外侧延伸的距离为（ ）。",[287,288,289,290],{"key":20,"text":276,"correct":22},{"key":24,"text":278,"correct":22},{"key":28,"text":280,"correct":22},{"key":31,"text":282,"correct":26},{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":20,"analysis":33},1112891,"供电企业的用电营业机构统一归口办理用户的（ ）和报装接电工作。",[295,297,299,301],{"key":20,"text":296,"correct":26},"用电申请",{"key":24,"text":298,"correct":22},"用电计划制定",{"key":28,"text":300,"correct":22},"用电维修人员审定",{"key":31,"text":302,"correct":22},"用电安全检查",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":31,"analysis":33},1112892,"办理申请用电手续时要签订协议或合同，规定供电和用电双方的权利和义务，用户有保护供电设施不受危害，确保用电安全的义务，同时还应明确双方的（ ）界限。",[307,309,311,313],{"key":20,"text":308,"correct":22},"用电时间",{"key":24,"text":310,"correct":22},"用电设备使用",{"key":28,"text":312,"correct":22},"用电区域管理",{"key":31,"text":314,"correct":26},"维护检修",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":31,"analysis":33},1112893,"自电网引入的线路施工和通电尚需一段时日，而工程又急需开工，总承包单位用自备电源（如柴油发电机组）时，总承包单位要（ ），同时要妥善采取安全技术措施，防止自备电源误入市政电网。",[319,321,323,325],{"key":20,"text":320,"correct":22},"上报供电部门备案",{"key":24,"text":322,"correct":22},"通过有关专家评定",{"key":28,"text":324,"correct":22},"确保自备电源工作安全可靠",{"key":31,"text":326,"correct":26},"告知供电部门并征得同意",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":24,"analysis":33},1112894,"用电计量装置的量值指示是电费结算的主要依据，依照有关法规规定该装置属强制检定范畴，由（ ）计量行政主管部门依法授权的检定机构进行检定合格，方为有效。",[331,333,335,337],{"key":20,"text":332,"correct":22},"部委",{"key":24,"text":334,"correct":26},"省级",{"key":28,"text":336,"correct":22},"市级",{"key":31,"text":338,"correct":22},"县级",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":31,"analysis":33},1112895,"用电计量装置原则上应装在供电设施的（ ）。",[343,345,347,349],{"key":20,"text":344,"correct":22},"供电侧",{"key":24,"text":346,"correct":22},"用户侧",{"key":28,"text":348,"correct":22},"内部",{"key":31,"text":350,"correct":26},"产权分界处",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":31,"analysis":33},1112896,"建造师在施工过程中应遵守用电安全规定，不允许（ ）。",[355,357,359,361],{"key":20,"text":356,"correct":22},"改变用电时间",{"key":24,"text":358,"correct":22},"减少合同约定的容量用电",{"key":28,"text":360,"correct":22},"减少计划分配的用电指标",{"key":31,"text":362,"correct":26},"擅自使用已经在供电企业办理暂停使用手续的电力设备",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":28,"analysis":33},1112897,"临时用电的准用程序中包括：①协助业主向当地电业部门申报用电方案；②经电业部门检查、验收和试验，同意送电后送电开通；③对施工项目进行检查、验收，向电业部门提供相关资料，申请送电；④进行临时用电设备、材料的采购和施工。其正确的准用程序是（ ）。",[367,369,371,373],{"key":20,"text":368,"correct":22},"①→③→④→②",{"key":24,"text":370,"correct":22},"③→④→①→②",{"key":28,"text":372,"correct":26},"①→④→③→②",{"key":31,"text":374,"correct":22},"④→③→①→②",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":20,"analysis":33},1112898,"供电部门和变电所的电力设施包含：变压器、（ ）以及输变电线路及电力电缆等。",[379,381,383,385],{"key":20,"text":380,"correct":26},"断路器",{"key":24,"text":382,"correct":22},"汽轮机",{"key":28,"text":384,"correct":22},"发电机",{"key":31,"text":386,"correct":22},"调相机",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":31,"analysis":33},1112899,"未经电力企业同意，不准在地下电力电缆沟内埋设输油输气等易燃易爆管道，管道交叉通过时，有关单位应当协商，并（ ），达成协议后方可施工。",[391,393,395,397],{"key":20,"text":392,"correct":22},"经项目经理同意",{"key":24,"text":394,"correct":22},"组织讨论",{"key":28,"text":396,"correct":22},"专家论证",{"key":31,"text":398,"correct":26},"采取安全措施",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":20,"analysis":33},1112900,"在施工方案中应专门制定（ ）措施，并写明要求。在作业时请电力设施的管理部门派员监管。",[403,405,407,409],{"key":20,"text":404,"correct":26},"保护电力设施的安全技术",{"key":24,"text":406,"correct":22},"用电设备管理",{"key":28,"text":408,"correct":22},"用电时间管理",{"key":31,"text":410,"correct":22},"用电人员持证上岗",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":28,"analysis":33},1112901,"临时用电工程应定期检查，基层公司应（ ）检查一次。",[415,417,419,421],{"key":20,"text":416,"correct":22},"每周",{"key":24,"text":418,"correct":22},"每月",{"key":28,"text":420,"correct":26},"每季",{"key":31,"text":422,"correct":22},"每天",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":31,"analysis":33},1112902,"因工作需要在距电力设施周围500m范围内进行爆破作业时，除采取可靠的安全防范措施外，还需（ ），报经政府有关部门批准。",[427,429,431,433],{"key":20,"text":428,"correct":22},"征得附近居民的同意",{"key":24,"text":430,"correct":22},"经过与建设单位讨论后同意",{"key":28,"text":432,"correct":22},"专家研究",{"key":31,"text":434,"correct":26},"征得当地电力设施产权单位的书面同意",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":31,"analysis":33},1112903,"总承包单位如果用自备电源（如柴油发电机组）解决用电问题时，应（ ），同时要妥善采取安全技术措施，防止自备电源误入市政电网。",[439,440,442,444],{"key":20,"text":320,"correct":22},{"key":24,"text":441,"correct":22},"进行专家论证",{"key":28,"text":443,"correct":22},"告知政府主管部门并征得同意",{"key":31,"text":326,"correct":26},{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":33},1112904,"关于用电计量装置的使用规定，正确的是（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":22},"由县级以上计量行政主管部门授权的检定机构进行检定合格",{"key":24,"text":452,"correct":26},"用电计量装置的设计应征得当地供电部门认可",{"key":28,"text":454,"correct":22},"用电计量装置在新装、换装及现场校验后，用户应对其加封",{"key":31,"text":456,"correct":22},"用电计量装置加封后，供电企业应在工作凭证上签章",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":31,"analysis":33},1112905,"施工现场临时用电工程的定期检查应复测（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":22},"绝缘电阻值",{"key":24,"text":464,"correct":22},"接地电流值",{"key":28,"text":466,"correct":22},"对地放电值",{"key":31,"text":468,"correct":26},"接地电阻值",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":28,"analysis":33},1112906,"临时用电工程专用的电源中性点直接接地的220V\u002F380V三相四线制低压电力系统，必须符合的规定不包括（ ）。 A.采用三级配电系统",[473,475,477,479],{"key":20,"text":474,"correct":22},"采用TN—S接零保护系统",{"key":24,"text":476,"correct":22},"采用TN—",{"key":28,"text":478,"correct":26},"系统",{"key":31,"text":480,"correct":22},"采用二级漏电保护系统",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":33},1112907,"施工现场临时用电采用TN-S系统应符合的规定不包括（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"电气设备的金属外壳必须与保护零线PE连接",{"key":24,"text":488,"correct":26},"B当施工现场与外电线路不是同一供电系统时，电气设备的接地、接零保护必须与外电系统一致",{"key":28,"text":490,"correct":22},"PE线必须在配电室、总配电箱重复接地",{"key":31,"text":492,"correct":22},"PE线接地电阻不应大于10Ω",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":28,"analysis":33},1112908,"电力线路设施的保护范围中，用于电力线路上的电器设备是（ ）。",[497,499,501,502],{"key":20,"text":498,"correct":22},"金具",{"key":24,"text":500,"correct":22},"绝缘子",{"key":28,"text":380,"correct":26},{"key":31,"text":503,"correct":22},"电力调度设施",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":20,"analysis":33},1112909,"任何单位或个人不得在距35KV及以下电力线路杆塔、拉线周围（ ）的区域内取土、打桩、钻探、开挖。",[508,509,510,511],{"key":20,"text":276,"correct":26},{"key":24,"text":278,"correct":22},{"key":28,"text":280,"correct":22},{"key":31,"text":282,"correct":22},{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":24,"analysis":33},1112910,"在电力设施保护区内或附近施工作业的要求不包括（ ）。",[516,518,520,522],{"key":20,"text":517,"correct":22},"认真进行图纸会审",{"key":24,"text":519,"correct":26},"制定的施工方案应包括周边电力设施的实情",{"key":28,"text":521,"correct":22},"编制施工方案时，尽量邀请电力管理部门或电力设施管理部门派员参加",{"key":31,"text":523,"correct":22},"在作业时请电力设施的管理部门派员监管",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":31,"analysis":33},1112913,"施工用电转入建设项目电力设施供电，总承包单位应及时向供电部门办理（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"变更用电手续",{"key":24,"text":531,"correct":22},"新装用电手续",{"key":28,"text":533,"correct":22},"正式用电手续",{"key":31,"text":535,"correct":26},"终止用电手续",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":20,"analysis":33},1112914,"未经批准在电力设施周围进行作业的，责令其停止作业的部门是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":26},"电力管理部门",{"key":24,"text":543,"correct":22},"安全管理部门",{"key":28,"text":545,"correct":22},"当地司法部门",{"key":31,"text":547,"correct":22},"当地公安部门",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":20,"analysis":33},1112915,"《特种设备安全法》确定的压力管道，是指利用一定的（ ），用于输送气体或者液体的灌装设备。",[552,554,556,558],{"key":20,"text":553,"correct":26},"压力",{"key":24,"text":555,"correct":22},"动力驱动",{"key":28,"text":557,"correct":22},"高度位差",{"key":31,"text":559,"correct":22},"热能",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":20,"analysis":33},1112916,"《特种设备安全监察条例》确定的压力管道，是指利用一定的（ ），用于输送气体或者液体的管状设备。",[564,565,566,567],{"key":20,"text":553,"correct":26},{"key":24,"text":555,"correct":22},{"key":28,"text":557,"correct":22},{"key":31,"text":559,"correct":22},{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":28,"analysis":33},1112917,"一般特种设备的安全技术档案不包括（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"监督检验证明",{"key":24,"text":575,"correct":22},"产品合格证明",{"key":28,"text":577,"correct":26},"能效测试报告",{"key":31,"text":579,"correct":22},"维修保养说明",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":31,"analysis":33},1112918,"根据输送介质的特性，输送（ ）的管道不属于压力管道范围。",[584,586,588,590],{"key":20,"text":585,"correct":22},"天然气",{"key":24,"text":587,"correct":22},"液化石油气",{"key":28,"text":589,"correct":22},"可燃易爆液体",{"key":31,"text":591,"correct":26},"生活用水",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":24,"analysis":33},1112919,"特种设备安全监察条例》所称的特种设备是指（ ）、危险性较大的设备和设施。",[596,598,600,602],{"key":20,"text":597,"correct":22},"制造和安装难度较大",{"key":24,"text":599,"correct":26},"涉及生命安全",{"key":28,"text":601,"correct":22},"重要性较大",{"key":31,"text":603,"correct":22},"具有特殊功能",[605,608,611,614,617,620],{"id":15,"name":606,"category":7,"favorite":607},"领导干部任职前廉政法规知识测试题",92,{"id":609,"name":610,"category":7,"favorite":15},595,"建筑结构与设备",{"id":612,"name":613,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":615,"name":616,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":618,"name":619,"category":7,"favorite":8},534,"BIM工程师",{"id":621,"name":619,"category":7,"favorite":8},535]