[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-787-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},787,"二建机电工程实务","建筑工程",0,18,50,2160,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,394,406,417,429,441,453,465,477,487,499,511,523,535,545,557,567,578,586,598],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1112710,1,"单选题","曳引式电梯设备的施工程序，缓冲器和对重装置安装之前的程序是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","曳引机和机房其他设备安装",true,{"key":24,"text":25,"correct":26},"B","轿厢组装",false,{"key":28,"text":29,"correct":26},"C","设备进场验收",{"key":31,"text":32,"correct":26},"D","曳引绳安装","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1112711,"电梯安装之前，所有厅门预留孔必须设有高度不小于（ ）的安全保护围封。",[38,40,42,44],{"key":20,"text":39,"correct":26},"800mm",{"key":24,"text":41,"correct":26},"1000mm",{"key":28,"text":43,"correct":26},"1100mm",{"key":31,"text":45,"correct":22},"1200mm",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1112712,"下列要求中，不符合导轨安装验收的有（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"导轨安装位置必须符合土建布置图要求",{"key":24,"text":53,"correct":26},"导轨支架在井道壁上的安装应固定可靠",{"key":28,"text":55,"correct":26},"轿厢导轨工作面接头处不应有连续缝隙",{"key":31,"text":57,"correct":22},"对重导轨工作面接头处可以有连续缝隙",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},1112713,"当相邻两电梯层门地坎间的距离大于（ ）时，其间必须设置井道安全门。",[62,64,66,68],{"key":20,"text":63,"correct":26},"7m",{"key":24,"text":65,"correct":26},"8m",{"key":28,"text":67,"correct":26},"10m",{"key":31,"text":69,"correct":22},"11m",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1112714,"当距轿底在1.1m以下使用玻璃轿壁时，必须在距轿底面（ ）的高度安装扶手。",[74,76,78,80],{"key":20,"text":75,"correct":26},"0.8m",{"key":24,"text":77,"correct":22},"1m",{"key":28,"text":79,"correct":26},"1.2m",{"key":31,"text":81,"correct":26},"1.5m",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1112715,"下列说法中，错误的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"每个绳头组合必须安装防螺母松动的装置",{"key":24,"text":89,"correct":26},"随行电缆严禁有打结和波浪扭曲现象",{"key":28,"text":91,"correct":26},"轿厢钢丝绳严禁有死弯",{"key":31,"text":93,"correct":22},"随行电缆长度与底坑地面接触",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1112716,"电梯在停电状态时，每层电梯层门必须用（ ）才能开启。",[98,100,102,104],{"key":20,"text":99,"correct":22},"三角钥匙",{"key":24,"text":101,"correct":26},"召唤器",{"key":28,"text":103,"correct":26},"专用工具",{"key":31,"text":105,"correct":26},"选层器",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1112717,"自动扶梯的梯级踏板上空，垂直净高度严禁小于（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"2.3m",{"key":24,"text":113,"correct":26},"2.6m",{"key":28,"text":115,"correct":26},"2.8m",{"key":31,"text":117,"correct":26},"3.0m",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},1112718,"自动扶梯进行空载制动试验时，（ ）应符合标准规范的要求。",[122,124,126,128],{"key":20,"text":123,"correct":22},"制停距离",{"key":24,"text":125,"correct":26},"制停速度",{"key":28,"text":127,"correct":26},"制停时间",{"key":31,"text":129,"correct":26},"制停载荷",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1112719,"电梯的渐进式安全钳验收时，轿厢应载有均匀分布的（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"额定载重量",{"key":24,"text":137,"correct":22},"125%额定载重量",{"key":28,"text":139,"correct":26},"150%额定载重量",{"key":31,"text":141,"correct":26},"200%额定载重量",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1112720,"电梯的主电源开关应（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"在电梯机房内部",{"key":24,"text":149,"correct":22},"能从机房入口处方便地接近",{"key":28,"text":151,"correct":26},"在电梯主机的旁边",{"key":31,"text":153,"correct":26},"在电梯控制箱内",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},1112721,"电梯的主要参数包括额定载重量和（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":26},"最大提升高度",{"key":24,"text":161,"correct":26},"载荷",{"key":28,"text":163,"correct":26},"工作速度",{"key":31,"text":165,"correct":22},"额定速度",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},1112722,"电梯安装单位应服从（ ）对施工现场的安全生产管理。",[170,172,174,176],{"key":20,"text":171,"correct":26},"建设单位",{"key":24,"text":173,"correct":26},"监理单位",{"key":28,"text":175,"correct":22},"施工总承包单位",{"key":31,"text":177,"correct":26},"分包单位",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},1112723,"电梯轿厢缓冲器支座下的底坑地面应能承受（ ）的作用力。",[182,184,186,188],{"key":20,"text":183,"correct":22},"满载轿厢静载4倍",{"key":24,"text":185,"correct":26},"满载轿厢动载4倍",{"key":28,"text":187,"correct":26},"满载轿厢静载2倍",{"key":31,"text":189,"correct":26},"满载轿厢动载2倍",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},1112725,"下列要求中，不符合安全部件安装验收要求的有（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":26},"限速器动作迅速整定封记完好",{"key":24,"text":197,"correct":22},"安全钳有拆动痕迹时应重新调节",{"key":28,"text":199,"correct":26},"轿厢与缓冲器顶面吻合",{"key":31,"text":201,"correct":26},"对重与缓冲器距离符合土建要求",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},1112726,"曳引式电梯施工程序中，轿厢组装的紧前工序是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"交接检验",{"key":24,"text":209,"correct":22},"导轨安装",{"key":28,"text":211,"correct":26},"对重安装",{"key":31,"text":213,"correct":26},"曳引机安装",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},1112727,"室内排水主管安装后均应作通球试验，通球球径不小于排水管径的三分之二，通球率达到（ ）为合格。",[218,220,222,224],{"key":20,"text":219,"correct":26},"85%",{"key":24,"text":221,"correct":26},"90%",{"key":28,"text":223,"correct":26},"95%",{"key":31,"text":225,"correct":22},"100%",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},1112728,"关于生活污水塑料管道的坡度，其管径125mm的最小坡度为（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":26},"12‰",{"key":24,"text":233,"correct":26},"8‰",{"key":28,"text":235,"correct":26},"6‰",{"key":31,"text":237,"correct":22},"5‰",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":31,"analysis":33},1112729,"明敷管道横干管穿越防火分区隔墙时，管道穿越墙体的两侧应隔墙设置防火套管的长度，可用的是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":26},"200mm",{"key":24,"text":245,"correct":26},"300mm",{"key":28,"text":247,"correct":26},"400mm",{"key":31,"text":249,"correct":22},"500mm",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":33},1112730,"塑料给水管道应在试验压力下稳压1h，然后在工作压力的1.15倍下稳压2h，压力降不得超过（ ），同时检查各连接处不得渗漏。",[254,256,258,260],{"key":20,"text":255,"correct":26},"0.01MPa",{"key":24,"text":257,"correct":26},"0.02MPa",{"key":28,"text":259,"correct":22},"0.03MPa",{"key":31,"text":261,"correct":26},"0.04MPa",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":28,"analysis":33},1112731,"室内排水立管与排出管端部的连接应采用（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":26},"一个45°弯头",{"key":24,"text":269,"correct":26},"一个90°斜四通",{"key":28,"text":271,"correct":22},"两个45°弯头",{"key":31,"text":273,"correct":26},"一个45°三通",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},1112732,"下列热水管道安装要求的说法，正确的有（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":26},"平行安装时热水管道应在冷水管道的下方",{"key":24,"text":281,"correct":22},"垂直安装时热水管道应在冷水管道的左侧",{"key":28,"text":283,"correct":26},"转弯安装时热水管道应在冷水管道的外侧",{"key":31,"text":285,"correct":26},"有坡度时热水管道的坡度应高于冷水管道",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":24,"analysis":33},1112733,"室内给水管道工程施工程序中，管道支架制作的紧后工序是（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":26},"管道测绘放线",{"key":24,"text":293,"correct":22},"管道加工预制",{"key":28,"text":295,"correct":26},"管道支架安装",{"key":31,"text":297,"correct":26},"管道元件安装",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},1112734,"高层建筑的雨水系统采用（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":22},"镀锌焊接钢管",{"key":24,"text":305,"correct":26},"镀锌无缝钢管",{"key":28,"text":307,"correct":26},"塑料管",{"key":31,"text":309,"correct":26},"球墨铸铁管",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":28,"analysis":33},1112735,"管道系统及配件安装属于建筑管道安装工程的（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":26},"分部工程",{"key":24,"text":317,"correct":26},"子分部工程",{"key":28,"text":319,"correct":22},"分项工程",{"key":31,"text":321,"correct":26},"检验批",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":31,"analysis":33},1112736,"室内消火栓系统在竣工后应做试射试验，首层取两处试验的目的是（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":26},"测两股水柱的出水流量",{"key":24,"text":329,"correct":26},"测两股水柱的出水压力",{"key":28,"text":331,"correct":26},"测两股水柱的出水流速",{"key":31,"text":333,"correct":22},"测两股水柱同时喷射到达最远点的能力",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":33},1112737,"同牌号、同型号、同规格的阀门安装前，应在每批数量中抽查（ ）作强度和严密性试验。",[338,340,342,344],{"key":20,"text":339,"correct":26},"5%",{"key":24,"text":341,"correct":22},"10%",{"key":28,"text":343,"correct":26},"15%",{"key":31,"text":345,"correct":26},"20%",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":20,"analysis":33},1112738,"管道穿过建筑地下室侧墙时应在（ ）进行安装。",[350,352,354,356],{"key":20,"text":351,"correct":22},"室内管道安装后",{"key":24,"text":353,"correct":26},"室内管道安装前",{"key":28,"text":355,"correct":26},"室内管道安装中",{"key":31,"text":357,"correct":26},"室内管道验收后",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},1112739,"金属给水管道系统在试验压力下观察（ ），压力降不应大于0.02MPa，然后降到工作压力进行检查，应不渗漏。",[362,364,366,368],{"key":20,"text":363,"correct":26},"5min",{"key":24,"text":365,"correct":22},"10min",{"key":28,"text":367,"correct":26},"15min",{"key":31,"text":369,"correct":26},"20min",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":33},1112740,"卫生间的埋地排水管道在隐蔽前必须做（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"灌水试验",{"key":24,"text":377,"correct":26},"水压试验",{"key":28,"text":379,"correct":26},"通球试验",{"key":31,"text":381,"correct":26},"泄漏试验",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":20,"analysis":33},1112741,"建筑供暖管道冲洗完毕后应（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"充水",{"key":24,"text":389,"correct":26},"试压",{"key":28,"text":391,"correct":26},"保温",{"key":31,"text":393,"correct":26},"防腐",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":28,"analysis":33},1112742,"具有保护水质卫生、抗腐蚀性强、使用寿命长等特点的管件是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":26},"铸铁连接管件",{"key":24,"text":401,"correct":26},"镀锌法兰管件",{"key":28,"text":403,"correct":22},"不锈钢卡压式管件",{"key":31,"text":405,"correct":26},"沟槽式管件",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":33},1112743,"排水塑料管在设计无要求时，伸缩节的间距不得大于（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"4m",{"key":24,"text":413,"correct":26},"5m",{"key":28,"text":415,"correct":26},"6m",{"key":31,"text":65,"correct":26},{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":28,"analysis":33},1112744,"建筑采暖管道穿过墙壁时应设置（ ）。",[421,423,425,427],{"key":20,"text":422,"correct":26},"水泥套管",{"key":24,"text":424,"correct":26},"铸铁套管",{"key":28,"text":426,"correct":22},"金属套管",{"key":31,"text":428,"correct":26},"瓷质套管",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":33},1112745,"在采暖工程施工中，散热器支管的坡度为（ ），坡度朝向应利于排气和泄水。",[433,435,437,439],{"key":20,"text":434,"correct":26},"0.5%",{"key":24,"text":436,"correct":26},"0.8%",{"key":28,"text":438,"correct":22},"1%",{"key":31,"text":440,"correct":26},"1.5%",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":20,"analysis":33},1112746,"室外排水管道工程的施工程序中，排水管道窨井施工完毕之后，应进行（ ）。",[445,447,449,451],{"key":20,"text":446,"correct":22},"系统闭水试验",{"key":24,"text":448,"correct":26},"管道沟槽回填",{"key":28,"text":450,"correct":26},"系统清洗",{"key":31,"text":452,"correct":26},"系统通水试验",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":20,"analysis":33},1112747,"具有保护水质卫生、抗腐蚀性强、使用寿命长等特点的管道连接方式是（ ）。",[457,459,461,463],{"key":20,"text":458,"correct":22},"卡压连接",{"key":24,"text":460,"correct":26},"沟槽连接",{"key":28,"text":462,"correct":26},"卡套式连接",{"key":31,"text":464,"correct":26},"法兰连接",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":28,"analysis":33},1112748,"建筑管道阀门试验要点不包括（ ）。",[469,471,473,475],{"key":20,"text":470,"correct":26},"安全阀应由具备资质的单位进行检定",{"key":24,"text":472,"correct":26},"闸阀应按规范要求进行强度和严密性试验",{"key":28,"text":474,"correct":22},"检验批要求同牌号、同型号、同时生产",{"key":31,"text":476,"correct":26},"主干管上起切断作用的闭路阀门，应逐个做强度试验和严密性试验",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":24,"analysis":33},1112749,"供暖管道系统冲洗完毕后，应（ ）、加热，进行试运行和调试。",[481,482,483,485],{"key":20,"text":389,"correct":26},{"key":24,"text":387,"correct":22},{"key":28,"text":484,"correct":26},"通球",{"key":31,"text":486,"correct":26},"灌水",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":31,"analysis":33},1112750,"建筑管道安装应遵循的配管原则有（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":26},"先塑料管后钢管",{"key":24,"text":494,"correct":26},"先小管后大管",{"key":28,"text":496,"correct":26},"先下部后上部",{"key":31,"text":498,"correct":22},"先垂直后水平",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":20,"analysis":33},1112751,"在设计不明确时，热水供应系统的水压试验为系统顶点的工作压力加（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"0.1MPA",{"key":24,"text":506,"correct":26},"0.2MPA",{"key":28,"text":508,"correct":26},"0.3MPA",{"key":31,"text":510,"correct":26},"0.4MPA",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":28,"analysis":33},1112752,"当设计未注明时，高温热水供暖系统水压试验压力为（ ）。 A.工作压力的1.5倍，且小于0.6MPA B.系统顶点的工作压力加0.1MP",[515,517,519,521],{"key":20,"text":516,"correct":26},"且系统顶点的试验压力不小于0.3MPA",{"key":24,"text":518,"correct":26},"系统最高点工作压力加0.4MPA",{"key":28,"text":520,"correct":22},"系统最高点工作压力加0.2MP",{"key":31,"text":522,"correct":26},"且系统最高点的试验压力不小于0.4MPA",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":28,"analysis":33},1112753,"室内给水管道施工程序中，管道安装的紧后工序是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":26},"防腐绝热",{"key":24,"text":530,"correct":26},"支架安装",{"key":28,"text":532,"correct":22},"压力试验",{"key":31,"text":534,"correct":26},"通水试验",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":20,"analysis":33},1112754,"卫生器具施工程序中，卫生器具安装的紧后工序是（ ）。",[539,541,543,544],{"key":20,"text":540,"correct":22},"给水配件安装",{"key":24,"text":542,"correct":26},"排水管道安装",{"key":28,"text":375,"correct":26},{"key":31,"text":534,"correct":26},{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},1112755,"自动喷水灭火系统的施工程序中，管道冲洗的紧前工序是（ ）。",[549,551,553,555],{"key":20,"text":550,"correct":26},"喷洒头安装",{"key":24,"text":552,"correct":22},"管道试压",{"key":28,"text":554,"correct":26},"系统通水调试",{"key":31,"text":556,"correct":26},"减压装置安装",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":20,"analysis":33},1112756,"管径小于或等于100mm的镀锌钢管宜用（ ）。",[561,563,565,566],{"key":20,"text":562,"correct":22},"螺纹连接",{"key":24,"text":564,"correct":26},"焊接连接",{"key":28,"text":464,"correct":26},{"key":31,"text":460,"correct":26},{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":20,"analysis":33},1112757,"阀门的强度试验压力为公称压力的（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":22},"1.5倍",{"key":24,"text":574,"correct":26},"1.1倍",{"key":28,"text":576,"correct":26},"1倍",{"key":31,"text":221,"correct":26},{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":24,"analysis":33},1112758,"阀门的严密性试验压力为公称压力的（ ）。",[582,583,584,585],{"key":20,"text":572,"correct":26},{"key":24,"text":574,"correct":22},{"key":28,"text":576,"correct":26},{"key":31,"text":221,"correct":26},{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":28,"analysis":33},1112759,"管道穿过有严格防水要求的建筑物，必须采用（ ）。",[590,592,594,596],{"key":20,"text":591,"correct":26},"钢套管",{"key":24,"text":593,"correct":26},"刚性防水套管",{"key":28,"text":595,"correct":22},"柔性防水套管",{"key":31,"text":597,"correct":26},"以上都对",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":28,"analysis":33},1112760,"安装在卫生间及厨房内的套管，其顶部应高出装饰地面（ ）。",[602,604,606,608],{"key":20,"text":603,"correct":26},"齐平",{"key":24,"text":605,"correct":26},"20mm",{"key":28,"text":607,"correct":22},"50mm",{"key":31,"text":609,"correct":26},"30mm",[611,614,617,620,623,626],{"id":15,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":15},595,"建筑结构与设备",{"id":618,"name":619,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":621,"name":622,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":624,"name":625,"category":7,"favorite":8},534,"BIM工程师",{"id":627,"name":625,"category":7,"favorite":8},535]