[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-787-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":605},{"id":5,"name":6,"category":7,"favorite":8},787,"二建机电工程实务","建筑工程",0,15,50,2160,[13,34,46,58,70,82,94,106,118,130,141,153,165,177,189,201,213,225,237,246,258,270,282,294,306,318,330,342,351,359,371,383,395,407,417,429,441,453,465,477,487,499,511,523,535,547,557,569,581,593],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1112553,1,"单选题","温度取源部件安装在合金管道拐弯处时，错误的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","在防腐、衬里、和压力试验前安装",false,{"key":24,"text":25,"correct":22},"B","用机械方法开孔",{"key":27,"text":28,"correct":22},"C","逆着物料流向安装",{"key":30,"text":31,"correct":32},"D","取源部件轴线与管道轴线垂直相交",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1112554,"管道三通部位金属保护层的安装，支管与主管相交部位宜翻边固定，采用顺水（ ）的连接方式。",[38,40,42,44],{"key":20,"text":39,"correct":22},"咬接",{"key":24,"text":41,"correct":32},"搭接",{"key":27,"text":43,"correct":22},"插接",{"key":30,"text":45,"correct":22},"嵌接",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},1112556,"管道上附件必须保冷，保冷层长度应大于等于保冷层厚度的（ ）倍或敷设至垫木处。",[50,52,54,56],{"key":20,"text":51,"correct":22},"1",{"key":24,"text":53,"correct":22},"2",{"key":27,"text":55,"correct":22},"3",{"key":30,"text":57,"correct":32},"4",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},1112557,"设备管道保冷层施工中，如采用一种保冷制品，当层厚大于（ ）时，应分两层或多层逐层施工。",[62,64,66,68],{"key":20,"text":63,"correct":22},"50mm",{"key":24,"text":65,"correct":22},"60mm",{"key":27,"text":67,"correct":22},"70mm",{"key":30,"text":69,"correct":32},"80mm",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},1112558,"管道保温层施工中，水平管道的保温层纵向接缝位置不得布置在（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":32},"管道垂直中心线45°范围内",{"key":24,"text":77,"correct":22},"管道垂直中心线60°范围内",{"key":27,"text":79,"correct":22},"管道水平中心线45°范围内",{"key":30,"text":81,"correct":22},"水平位置",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},1112559,"当蒸汽伴热管采用软质绝热制品保温时，应先用镀锌铁丝网或“V”形金属件热罩将伴热管包裹在主管上并扎紧，保留一定的（ ），然后再进行保温",[86,88,90,92],{"key":20,"text":87,"correct":22},"接触",{"key":24,"text":89,"correct":22},"贴紧",{"key":27,"text":91,"correct":32},"空隙",{"key":30,"text":93,"correct":22},"一定角度",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},1112560,"管道保冷结构金属保护层的纵向接缝应采用金属包装带抱箍固定，间距宜为（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"150～200mm",{"key":24,"text":101,"correct":22},"200～250mm",{"key":27,"text":103,"correct":32},"250～300mm",{"key":30,"text":105,"correct":22},"300～400mm",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1112561,"垂直管道或设备金属保护层的敷设方法和要求是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":32},"由下而上施工，接缝上搭下",{"key":24,"text":113,"correct":22},"由上而下施工，接缝上搭下",{"key":27,"text":115,"correct":22},"由下而上施工，接缝下搭上",{"key":30,"text":117,"correct":22},"由上而下施工，接缝下搭上",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1112562,"金属保护层的接缝可选用搭接、咬接、插接及嵌接的形式。下列关于金属保护层接缝选用形式的说法，正确的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"纵向接缝可采用插接",{"key":24,"text":125,"correct":32},"纵向接缝可采用搭接或咬接",{"key":27,"text":127,"correct":22},"室内的外保护层结构宜采用插接",{"key":30,"text":129,"correct":22},"环向接缝可采用咬接或嵌接",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},1112563,"关于金属保护层的接缝选用形式，不正确的是（ ）。",[134,135,137,139],{"key":20,"text":125,"correct":22},{"key":24,"text":136,"correct":22},"环向接缝可采用插接",{"key":27,"text":138,"correct":32},"环向接缝可采用咬接",{"key":30,"text":140,"correct":22},"室内的外保护层结构，宜采用搭接形式",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":27,"analysis":33},1112564,"管道采用预制块做保温层的要求是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"同层应错缝，上下层应压缝，用高一等级材料的胶泥勾缝",{"key":24,"text":148,"correct":22},"同层应压缝，上下层应错缝，用同等级材料的胶泥勾缝",{"key":27,"text":150,"correct":32},"同层应错缝，上下层应压缝，用同等级材料的胶泥勾缝",{"key":30,"text":152,"correct":22},"同层应压缝，上下层应错缝，用高一等级材料的胶泥勾缝",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":30,"analysis":33},1112565,"管道除锈质量要求达到St2级，采用的表面处理方法是（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"化学处理",{"key":24,"text":160,"correct":22},"抛丸处理",{"key":27,"text":162,"correct":22},"喷砂处理",{"key":30,"text":164,"correct":32},"工具清理",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":24,"analysis":33},1112566,"钢结构用水性防腐涂料产品，不包括（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"底漆",{"key":24,"text":172,"correct":32},"色漆",{"key":27,"text":174,"correct":22},"面漆",{"key":30,"text":176,"correct":22},"中间漆",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":27,"analysis":33},1112567,"管道保温层分为两层时，下列说法错误的是（ ）。",[181,183,185,187],{"key":20,"text":182,"correct":22},"各层厚度宜接近",{"key":24,"text":184,"correct":22},"两层之间应压缝",{"key":27,"text":186,"correct":32},"保温材料应一致",{"key":30,"text":188,"correct":22},"同层接缝应错缝",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":30,"analysis":33},1112568,"管道除锈质量要求达到St2级，采用的除锈方法是（ ）。",[193,195,197,199],{"key":20,"text":194,"correct":22},"化学除锈",{"key":24,"text":196,"correct":22},"火焰除锈",{"key":27,"text":198,"correct":22},"喷砂除锈",{"key":30,"text":200,"correct":32},"手工除锈",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":30,"analysis":33},1112569,"下列管道保温作业的做法，正确的是（ ）。",[205,207,209,211],{"key":20,"text":206,"correct":22},"水平管道的纵向接缝位置应布置在管道垂直中心线45°范围内",{"key":24,"text":208,"correct":22},"双层或多层保温制品施工捆扎，最后找平和严缝",{"key":27,"text":210,"correct":22},"用钢带捆扎保温层，每节管壳至少捆扎一道",{"key":30,"text":212,"correct":32},"同层保温预制块的接缝要对齐",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":30,"analysis":33},1112570,"下列设备管道保冷层施工要求中，正确的是（ ）。",[217,219,221,223],{"key":20,"text":218,"correct":22},"绝热层各层表面可不做严缝处理",{"key":24,"text":220,"correct":22},"水平管道的纵向接缝位置，必须布置在管道垂直中心线45度范围内",{"key":27,"text":222,"correct":22},"硬质或半硬质材料作保冷层，拼缝宽度不应大于10mm",{"key":30,"text":224,"correct":32},"保冷制品层厚大于80mm时，应分两或多层逐层施工",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},1112571,"耐火浇筑料施工程序中，膨胀缝填充的紧前工序是（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":32},"模板拆除",{"key":24,"text":232,"correct":22},"浇筑料振捣",{"key":27,"text":234,"correct":22},"浇筑料浇筑",{"key":30,"text":236,"correct":22},"成品养护",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":20,"analysis":33},1112572,"硅藻土砖砌筑时，其砖缝不应大于（ ）mm。",[241,243,244,245],{"key":20,"text":242,"correct":32},"5",{"key":24,"text":55,"correct":22},{"key":27,"text":53,"correct":22},{"key":30,"text":51,"correct":22},{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},1112573,"下列砌筑施工人员中，不属于特殊工种的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":32},"筑炉工",{"key":24,"text":253,"correct":22},"叉车司机",{"key":27,"text":255,"correct":22},"架子工",{"key":30,"text":257,"correct":22},"焊工",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":27,"analysis":33},1112574,"下列耐火材料中，属于高级耐火材料的是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"耐火度为1560℃",{"key":24,"text":265,"correct":22},"耐火度为1700℃",{"key":27,"text":267,"correct":32},"耐火度为1800℃",{"key":30,"text":269,"correct":22},"耐火度为2100℃",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":27,"analysis":33},1112575,"炉窑砌筑时，吊挂拱顶锁砖应遵循（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"不宜锁得太紧",{"key":24,"text":277,"correct":22},"整体同时锁紧",{"key":27,"text":279,"correct":32},"分环锁紧，锁紧度一致",{"key":30,"text":281,"correct":22},"分段锁紧，每段锁紧度应一致",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":20,"analysis":33},1112576,"下列耐火喷涂料施工技术要点中，错误的是（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":32},"采用湿法喷涂",{"key":24,"text":289,"correct":22},"喷涂方向应垂直于受喷面",{"key":27,"text":291,"correct":22},"分段连续喷涂",{"key":30,"text":293,"correct":22},"一次喷到设计厚度",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":24,"analysis":33},1112577,"与浇注料接触的隔热砌体表面，应采取（ ）措施。",[298,300,302,304],{"key":20,"text":299,"correct":22},"保温",{"key":24,"text":301,"correct":32},"防水",{"key":27,"text":303,"correct":22},"固定",{"key":30,"text":305,"correct":22},"保证热涨冷缩",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":30,"analysis":33},1112578,"下列耐火材料中，属于酸性耐火材料的是（ ）。",[310,312,314,316],{"key":20,"text":311,"correct":22},"镁砖",{"key":24,"text":313,"correct":22},"碳砖",{"key":27,"text":315,"correct":22},"高铝砖",{"key":30,"text":317,"correct":32},"硅砖",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":20,"analysis":33},1112579,"下列耐火材料中，属于中性耐火材料的是（ ）。",[322,324,326,328],{"key":20,"text":323,"correct":32},"刚玉砖",{"key":24,"text":325,"correct":22},"镁铝砖",{"key":27,"text":327,"correct":22},"白云石砖",{"key":30,"text":329,"correct":22},"锆英砂砖",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},1112580,"动态炉窑砌筑是从（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":32},"工作温度的热端处",{"key":24,"text":337,"correct":22},"离传动最近的焊缝处",{"key":27,"text":339,"correct":22},"检修孔（门）处",{"key":30,"text":341,"correct":22},"支撑位置处",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":30,"analysis":33},1112581,"可用作隔热耐火砖的是（ ）。",[346,347,348,349],{"key":20,"text":311,"correct":22},{"key":24,"text":325,"correct":22},{"key":27,"text":313,"correct":22},{"key":30,"text":350,"correct":32},"高铝质砖",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":24,"analysis":33},1112582,"圆形炉墙砌筑时，重缝不得超过（ ）层（环）。",[355,356,357,358],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":32},{"key":27,"text":57,"correct":22},{"key":30,"text":242,"correct":22},{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":24,"analysis":33},1112583,"耐火砖锁砖时，宜（ ）。",[363,365,367,369],{"key":20,"text":364,"correct":22},"用手锤打入",{"key":24,"text":366,"correct":32},"用木锤打入",{"key":27,"text":368,"correct":22},"用压力机加铁片压入",{"key":30,"text":370,"correct":22},"加铁片用手锤打入",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":20,"analysis":33},1112584,"烘炉时，烘炉体前应先烘（ ）。",[375,377,379,381],{"key":20,"text":376,"correct":32},"烟囱及烟道",{"key":24,"text":378,"correct":22},"进风管道",{"key":27,"text":380,"correct":22},"物料输入系统",{"key":30,"text":382,"correct":22},"物料输出系统",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":27,"analysis":33},1112585,"拱和拱顶必须从（ ）砌筑，严禁将拱砖的大小头倒置。",[387,389,391,393],{"key":20,"text":388,"correct":22},"两侧向中心",{"key":24,"text":390,"correct":22},"热端向冷端",{"key":27,"text":392,"correct":32},"两侧拱脚同时向中心对称",{"key":30,"text":394,"correct":22},"冷端向热端",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":20,"analysis":33},1112586,"圆形炉墙砌筑时，若炉壳的中心线垂直误差和半径误差符合炉内形的要求时，可（ ）砌筑。",[399,401,403,405],{"key":20,"text":400,"correct":32},"以炉壳为导面",{"key":24,"text":402,"correct":22},"以进料口为基准",{"key":27,"text":404,"correct":22},"以出料口为基准",{"key":30,"text":406,"correct":22},"以炉壳的中心线为基准",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":24,"analysis":33},1112587,"炉窑湿砌时，每段长度不得大于（ ）m。",[411,413,414,416],{"key":20,"text":412,"correct":22},"0.5",{"key":24,"text":51,"correct":32},{"key":27,"text":415,"correct":22},"1.5",{"key":30,"text":53,"correct":22},{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":24,"analysis":33},1112589,"下列说法不符合耐火陶瓷纤维施工技术的是（ ）。",[421,423,425,427],{"key":20,"text":422,"correct":22},"制品不得受挤压",{"key":24,"text":424,"correct":32},"切割制品时，切口应呈阶梯形",{"key":27,"text":426,"correct":22},"胶粘剂应搅拌均匀",{"key":30,"text":428,"correct":22},"粘贴面应平整",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":27,"analysis":33},1112590,"下列耐火材料中，属于按结构性能分类的是（ ）。",[433,435,437,439],{"key":20,"text":434,"correct":22},"碱性耐火材料",{"key":24,"text":436,"correct":22},"高级耐火材料",{"key":27,"text":438,"correct":32},"隔热耐火材料",{"key":30,"text":440,"correct":22},"不定型耐火材料",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":27,"analysis":33},1112591,"耐火喷涂料施工中断时，宜将接槎处做成（ ）。",[445,447,449,451],{"key":20,"text":446,"correct":22},"直斜槎",{"key":24,"text":448,"correct":22},"梯形斜槎",{"key":27,"text":450,"correct":32},"直槎",{"key":30,"text":452,"correct":22},"齿形直槎",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":30,"analysis":33},1112592,"工业炉的烘干应在（ ）进行。",[457,459,461,463],{"key":20,"text":458,"correct":22},"炉窑砌筑后即可",{"key":24,"text":460,"correct":22},"炉窑砌筑及相关设备安装结束后",{"key":27,"text":462,"correct":22},"单机无负荷试运转后",{"key":30,"text":464,"correct":32},"联合试运转后",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":27,"analysis":33},1112593,"室内照明灯具的施工程序中，灯具安装接线的紧后工序是（ ）",[469,471,473,475],{"key":20,"text":470,"correct":22},"导线并头",{"key":24,"text":472,"correct":22},"绝缘测试",{"key":27,"text":474,"correct":32},"送电前检查",{"key":30,"text":476,"correct":22},"灯管安装",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":24,"analysis":33},1112594,"母线槽安装完毕后，应进行（ ）。",[481,483,484,485],{"key":20,"text":482,"correct":22},"交接试验",{"key":24,"text":472,"correct":32},{"key":27,"text":474,"correct":22},{"key":30,"text":486,"correct":22},"送电验收",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":27,"analysis":33},1112595,"电气设备的独立接地体，其接地电阻应（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":22},"小于1Ω",{"key":24,"text":494,"correct":22},"大于1Ω",{"key":27,"text":496,"correct":32},"小于4Ω",{"key":30,"text":498,"correct":22},"大于4Ω",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":24,"analysis":33},1112596,"建筑物等电位联结按等电位联结的作用范围分类，不包括（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"总等电位联结",{"key":24,"text":506,"correct":32},"独立等电位连接",{"key":27,"text":508,"correct":22},"辅助等电位联结",{"key":30,"text":510,"correct":22},"局部等电位联结",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":20,"analysis":33},1112597,"建筑屋顶上的接闪带应使用（ ）制作。",[515,517,519,521],{"key":20,"text":516,"correct":32},"40mm×4mm镀锌扁钢",{"key":24,"text":518,"correct":22},"BΦ10mm镀锌圆钢",{"key":27,"text":520,"correct":22},"G25mm镀锌钢管",{"key":30,"text":522,"correct":22},"L40mm×4mm镀锌角钢",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":33},1112598,"接地支线沿建筑物墙壁水平敷设时，离地面距离宜为（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":32},"0.3m",{"key":24,"text":530,"correct":22},"0.5m",{"key":27,"text":532,"correct":22},"1.0m",{"key":30,"text":534,"correct":22},"1.3m",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":30,"analysis":33},1112599,"当金属筒体的厚度不小于（ ）时，可作接闪杆的引下线，筒体底部应有两处与接地体连接",[539,541,543,545],{"key":20,"text":540,"correct":22},"1.5mm",{"key":24,"text":542,"correct":22},"2mm",{"key":27,"text":544,"correct":22},"2.5mm",{"key":30,"text":546,"correct":32},"4mm",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":30,"analysis":33},1112600,"金属筒体上安装避雷针，金属筒体的厚度不小于（ ）时，可作避雷针的引下线。",[551,552,554,556],{"key":20,"text":544,"correct":22},{"key":24,"text":553,"correct":22},"3mm",{"key":27,"text":555,"correct":22},"3.5mm",{"key":30,"text":546,"correct":32},{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":24,"analysis":33},1112601,"成套配电柜的安装程序中，配电柜安装固定的紧后工序是（ ）。",[561,563,565,567],{"key":20,"text":562,"correct":22},"开箱检查",{"key":24,"text":564,"correct":32},"母线安装",{"key":27,"text":566,"correct":22},"小线连接",{"key":30,"text":568,"correct":22},"试验调整",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},1112602,"电缆敷设施工程序中，电缆敷设紧后工序是（ ）。",[573,575,577,579],{"key":20,"text":574,"correct":22},"电缆搬运",{"key":24,"text":576,"correct":32},"绝缘测定",{"key":27,"text":578,"correct":22},"挂标志",{"key":30,"text":580,"correct":22},"质量验收",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":30,"analysis":33},1112603,"下列设备中，可不与接闪器连接成一体的有（ ）。",[585,587,589,591],{"key":20,"text":586,"correct":22},"铁栏杆",{"key":24,"text":588,"correct":22},"金属柱灯",{"key":27,"text":590,"correct":22},"冷却塔",{"key":30,"text":592,"correct":32},"塑钢窗",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":24,"analysis":33},1112604,"下列自然接地体的施工技术要求，正确的是（ ）。",[597,599,601,603],{"key":20,"text":598,"correct":22},"将底板内一根主钢筋搭接焊接，并做好标记",{"key":24,"text":600,"correct":32},"将底板内二根主钢筋搭接焊接，并做好标记",{"key":27,"text":602,"correct":22},"把工程桩内的钢筋与底板钢筋焊接牢固",{"key":30,"text":604,"correct":22},"将底板内钢筋与接地网相连接",[606,609,612,615,618,621],{"id":15,"name":607,"category":7,"favorite":608},"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":15},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]